Tele Process Pump Controller, 12V ac, 400 V ac, 55 °C
- RS-stocknr.:
- 182-9996
- Fabrikantnummer:
- G2ASMA20
- Fabrikant:
- Tele
Subtotaal (1 eenheid)*
€ 166,59
(excl. BTW)
€ 201,57
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Op voorraad
- Plus verzending 1 stuk(s) vanaf 11 mei 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 166,59 |
*prijsindicatie
- RS-stocknr.:
- 182-9996
- Fabrikantnummer:
- G2ASMA20
- Fabrikant:
- Tele
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Tele | |
| Product Type | Process Pump Controller | |
| Supply Voltage | 12, 400V ac | |
| IP Rating | IP40, IP20 | |
| Maximum Fluid Temperature | 55°C | |
| Standards/Approvals | IEC 68-1, VBG 4, IEC 947-5-1, IEC 721-3-3 Klasse 3k3, IEC 68-2-6, IEC 68-2-27, IEC 60664-1, IEC 60444-1, EN 50022 | |
| Alles selecteren | ||
|---|---|---|
Merk Tele | ||
Product Type Process Pump Controller | ||
Supply Voltage 12, 400V ac | ||
IP Rating IP40, IP20 | ||
Maximum Fluid Temperature 55°C | ||
Standards/Approvals IEC 68-1, VBG 4, IEC 947-5-1, IEC 721-3-3 Klasse 3k3, IEC 68-2-6, IEC 68-2-27, IEC 60664-1, IEC 60444-1, EN 50022 | ||
- Land van herkomst:
- AT
Pump control, Alternating/parallel
Alternated access of two pumps or other devices
Even distribution of duty
Parallel duty at high demand
Operation using 1 or 2 input signals (two modes of operation)
Timing offset of the two loads to avoid water hammer effcects
Supply voltage selectable via TR2 power modules
2 separate change over relays for device control
Width 22.5mm
Industrial design
Task
Two pumps are installed at a sewage pumping station that are to be run alternately for equal periods to ensure equal wear.
Solution
The pump switchover system activates the pumps alternately, if needed, the second pump can also be activated so that both run at the same time (parallel operation)
Use/value
Equal wear, and therefore longer service intervals for both pumps
Minimised pump failures through nearly equal number of operating hours
Peak load coverage
Zero-voltage safety in the event of power failures
Applications
Centrifugal Pumps
Sewage Pumps
Water & Waste
Gerelateerde Links
- Xylem Lowara Process Pump Controller for Diaphragm, 220/240 V, 60 °C
- Sensata / Cynergy3 Process Pump Controller for Centrifugal, 250 V ac, 45 °C
- Sensata / Cynergy3 Process Pump Controller for Hydromatic, 240 V ac, 60 °C
- RS PRO Process Pump Controller for Brushless Micropump, 6/28 V, 80 °C
- Pump Controllers
- RS PRO Process Pump Controller for Brushless Micropump, 6/28 V dc, 80 °C
- RS PRO Process Pump Controller for Brushless Micropump, 6/28 V
- TRACOPOWER TEL 12 DC/DC Converter, 15V dc/ 400 mA, 75V dc Input, 36V Input 12 W, PCB, 88 °C Max Temp -40 °C Min Temp,
