Fluke calibration 8808A/TL 240V 8808A Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac, RSCAL Calibrated
- RS-stocknr.:
- 260-2797
- Fabrikantnummer:
- 8808A/TL 240V
- Fabrikant:
- Fluke calibration
Subtotaal (1 eenheid)*
€ 1.405,00
(excl. BTW)
€ 1.700,05
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
- Verzending 1 stuk(s) vanaf 13 augustus 2026
- Plus verzending 1 stuk(s) vanaf 20 augustus 2026
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 1.405,00 |
*prijsindicatie
- RS-stocknr.:
- 260-2797
- Fabrikantnummer:
- 8808A/TL 240V
- Fabrikant:
- Fluke calibration
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke calibration | |
| Multimeter Type | Bench | |
| Product Type | Multimeter | |
| Display Type | Digital | |
| Model Number | 8808A/TL 240V | |
| Resistance Resolution | 1mΩ | |
| Functions Measured | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Frequency, Resistance, Temperature | |
| Maximum AC Voltage Measurement | 750V ac | |
| Maximum Resistance Measurement | 100mΩ | |
| Maximum AC Current Measurement | 10A ac | |
| Maximum DC Voltage Measurement | 1kV dc | |
| Maximum DC Current Measurement | 10A dc | |
| True RMS | Yes | |
| AC Current Accuracy | ±0.3 % rdg | |
| DC Current Accuracy | 0.02 % rdg | |
| DC Voltage Accuracy | ±0.015 % rdg + 0.003 | |
| AC Voltage Accuracy | ±0.2 % rdg | |
| AC Voltage Resolution | 1V ac | |
| AC Current Resolution | 100μA ac | |
| DC Voltage Resolution | 1 μV | |
| DC Current Resolution | 1nA ac | |
| Maximum Frequency | 440Hz | |
| Resistance Measurement Accuracy | 0.02 % rdg + 0.003 % range | |
| Minimum Operating Temperature | 0°C | |
| Width | 217mm | |
| Standards/Approvals | ANSI/ISA 61010-1 (S82.02.01):2004, AN/CSA C22.2, EN 61010-1:2001, UL 61010-1:2004 | |
| Series | 8808A | |
| Weight | 2.1kg | |
| Height | 88mm | |
| Length | 297mm | |
| Safety Category Level | Connector Bracket, Joint | |
| Safety Category Voltage | 1000V dc | |
| Calibrated | RSCAL | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke calibration | ||
Multimeter Type Bench | ||
Product Type Multimeter | ||
Display Type Digital | ||
Model Number 8808A/TL 240V | ||
Resistance Resolution 1mΩ | ||
Functions Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Frequency, Resistance, Temperature | ||
Maximum AC Voltage Measurement 750V ac | ||
Maximum Resistance Measurement 100mΩ | ||
Maximum AC Current Measurement 10A ac | ||
Maximum DC Voltage Measurement 1kV dc | ||
Maximum DC Current Measurement 10A dc | ||
True RMS Yes | ||
AC Current Accuracy ±0.3 % rdg | ||
DC Current Accuracy 0.02 % rdg | ||
DC Voltage Accuracy ±0.015 % rdg + 0.003 | ||
AC Voltage Accuracy ±0.2 % rdg | ||
AC Voltage Resolution 1V ac | ||
AC Current Resolution 100μA ac | ||
DC Voltage Resolution 1 μV | ||
DC Current Resolution 1nA ac | ||
Maximum Frequency 440Hz | ||
Resistance Measurement Accuracy 0.02 % rdg + 0.003 % range | ||
Minimum Operating Temperature 0°C | ||
Width 217mm | ||
Standards/Approvals ANSI/ISA 61010-1 (S82.02.01):2004, AN/CSA C22.2, EN 61010-1:2001, UL 61010-1:2004 | ||
Series 8808A | ||
Weight 2.1kg | ||
Height 88mm | ||
Length 297mm | ||
Safety Category Level Connector Bracket, Joint | ||
Safety Category Voltage 1000V dc | ||
Calibrated RSCAL | ||
- Land van herkomst:
- CN
Fluke 8808A Series Multimeter, 1000V Safety Category Voltage, 10A Maximum DC Current Measurement - FLUKE 8808A/TL 240V
Features and Benefits:
• 1μV DC resolution facilitates detection of very small voltage changes
• 10A AC/DC current measurement supports power and load testing
• 100 mΩ low‑resistance range allows sensitive contact‑resistance checks
• 1 kV DC maximum rating permits high‑voltage component evaluation
• ±0.3% AC current accuracy ensures reliable alternating‑current readings
Applications
• Ideal for calibration laboratories requiring fine DC resolution
• Used with temperature sensors for thermal characterisation
• Can be used for capacitor testing during quality inspection
• Suitable for frequency response checks up to 440 Hz
What safety categories and approvals does it meet?
How does the display and form factor support bench use?
What are the environmental operating constraints?
What measurement resolutions are available for resistance and AC voltage?
Gerelateerde Links
- Fluke calibration 8808A/TL 240V Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac, UKAS Calibrated
- Fluke calibration 8808A/TL 240V Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac
- Fluke calibration 8808A Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac, UKAS Calibrated
- Fluke calibration 8808A Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac, RSCAL Calibrated
- Fluke calibration 8808A/SU Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 1 kV ac, RSCAL Calibrated
- Fluke calibration 8808A/SU Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 1 kV ac, UKAS Calibrated
- Fluke calibration 8808A Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac
- Fluke calibration 8808A/SU Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 1 kV ac