Fluke calibration 8808A/SU 8808A Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac, RSCAL Calibrated
- RS-stocknr.:
- 260-2792
- Fabrikantnummer:
- 8808A/SU 240V
- Fabrikant:
- Fluke calibration
Subtotaal (1 eenheid)*
€ 1.590,00
(excl. BTW)
€ 1.923,90
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
- Verzending 2 stuk(s) vanaf 01 oktober 2026
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 1.590,00 |
*prijsindicatie
- RS-stocknr.:
- 260-2792
- Fabrikantnummer:
- 8808A/SU 240V
- Fabrikant:
- Fluke calibration
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke calibration | |
| Product Type | Multimeter | |
| Multimeter Type | Bench | |
| Display Type | Digital | |
| Model Number | 8808A/SU | |
| Resistance Resolution | 1mΩ | |
| Functions Measured | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Frequency, Resistance, Temperature | |
| Maximum AC Current Measurement | 10A ac | |
| Maximum DC Current Measurement | 10A dc | |
| Maximum DC Voltage Measurement | 1kV dc | |
| Maximum Resistance Measurement | 100mΩ | |
| Maximum AC Voltage Measurement | 750V ac | |
| True RMS | Yes | |
| AC Voltage Accuracy | ±0.2 % rdg | |
| DC Voltage Accuracy | ±0.015 % rdg + 0.003 | |
| DC Current Accuracy | 0.02 % rdg | |
| AC Current Accuracy | ±0.3 % rdg | |
| AC Current Resolution | 100μA ac | |
| DC Voltage Resolution | 1 μV | |
| AC Voltage Resolution | 1V ac | |
| DC Current Resolution | 1nA ac | |
| Maximum Frequency | 440Hz | |
| Minimum Operating Temperature | 0°C | |
| Resistance Measurement Accuracy | 0.02 % rdg + 0.003 % range | |
| Length | 297mm | |
| Height | 88mm | |
| Standards/Approvals | UL 61010-1:2004, EN 61010-1:2001, AN/CSA C22.2, ANSI/ISA 61010-1 (S82.02.01):2004 | |
| Series | 8808A | |
| Weight | 2.1kg | |
| Width | 217mm | |
| Safety Category Level | Joint, Connector Bracket | |
| Calibrated | RSCAL | |
| Safety Category Voltage | 1000V ac | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke calibration | ||
Product Type Multimeter | ||
Multimeter Type Bench | ||
Display Type Digital | ||
Model Number 8808A/SU | ||
Resistance Resolution 1mΩ | ||
Functions Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Frequency, Resistance, Temperature | ||
Maximum AC Current Measurement 10A ac | ||
Maximum DC Current Measurement 10A dc | ||
Maximum DC Voltage Measurement 1kV dc | ||
Maximum Resistance Measurement 100mΩ | ||
Maximum AC Voltage Measurement 750V ac | ||
True RMS Yes | ||
AC Voltage Accuracy ±0.2 % rdg | ||
DC Voltage Accuracy ±0.015 % rdg + 0.003 | ||
DC Current Accuracy 0.02 % rdg | ||
AC Current Accuracy ±0.3 % rdg | ||
AC Current Resolution 100μA ac | ||
DC Voltage Resolution 1 μV | ||
AC Voltage Resolution 1V ac | ||
DC Current Resolution 1nA ac | ||
Maximum Frequency 440Hz | ||
Minimum Operating Temperature 0°C | ||
Resistance Measurement Accuracy 0.02 % rdg + 0.003 % range | ||
Length 297mm | ||
Height 88mm | ||
Standards/Approvals UL 61010-1:2004, EN 61010-1:2001, AN/CSA C22.2, ANSI/ISA 61010-1 (S82.02.01):2004 | ||
Series 8808A | ||
Weight 2.1kg | ||
Width 217mm | ||
Safety Category Level Joint, Connector Bracket | ||
Calibrated RSCAL | ||
Safety Category Voltage 1000V ac | ||
- Land van herkomst:
- CN
Fluke 8808A Series Multimeter, 1000V Safety Category Voltage, 10A Maximum DC Current Measurement - FLUKE 8808A/SU 240V
Features and Benefits:
• True RMS measurement ensures accurate AC waveform assessment
• Maximum DC voltage 1000V supports high‑voltage testing
• Resistance range to 100 mΩ enables low‑resistance diagnostics
• AC/DC current capability up to 10A handles power measurements
• DC resolution 1 μV reveals very small voltage changes
Applications
• Ideal for calibration benches requiring high‑accuracy readings
• Used for power‑supply verification up to 1000V DC
• Can be used for low‑resistance contact testing and shunt checks
• Used with thermal sensors for temperature‑related measurements
What measurement functions does it provide beyond volts and amps?
How does it perform with AC signals of varying shapes?
What is the maximum frequency it can measure?
What safety credentials does the instrument meet for high‑voltage work?
Gerelateerde Links
- Fluke calibration 8808A/SU Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 1 kV ac, UKAS Calibrated
- Fluke calibration 8808A Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac, UKAS Calibrated
- Fluke calibration 8808A Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac, RSCAL Calibrated
- Fluke calibration 8808A/SU Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 1 kV ac
- Fluke calibration 8808A Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac
- Fluke calibration 8808A/TL 240V Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac, RSCAL Calibrated
- Fluke calibration 8808A/TL 240V Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac, UKAS Calibrated
- Fluke calibration 8808A/TL 240V Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac