Fluke calibration 8808A/SU 8808A Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac, UKAS Calibrated
- RS-stocknr.:
- 260-2794
- Fabrikantnummer:
- 8808A/SU 240V
- Fabrikant:
- Fluke calibration
Subtotaal (1 eenheid)*
€ 1.636,00
(excl. BTW)
€ 1.979,56
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
- Verzending 2 stuk(s) vanaf 01 oktober 2026
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 1.636,00 |
*prijsindicatie
- RS-stocknr.:
- 260-2794
- Fabrikantnummer:
- 8808A/SU 240V
- Fabrikant:
- Fluke calibration
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke calibration | |
| Product Type | Multimeter | |
| Multimeter Type | Bench | |
| Display Type | Digital | |
| Resistance Resolution | 1mΩ | |
| Model Number | 8808A/SU | |
| Functions Measured | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Frequency, Resistance, Temperature | |
| Maximum AC Voltage Measurement | 750V ac | |
| Maximum AC Current Measurement | 10A ac | |
| Maximum DC Current Measurement | 10A dc | |
| Maximum Resistance Measurement | 100mΩ | |
| Maximum DC Voltage Measurement | 1kV dc | |
| True RMS | Yes | |
| DC Voltage Accuracy | ±0.015 % rdg + 0.003 | |
| DC Current Accuracy | 0.02 % rdg | |
| AC Voltage Accuracy | ±0.2 % rdg | |
| AC Current Accuracy | ±0.3 % rdg | |
| AC Current Resolution | 100μA ac | |
| DC Current Resolution | 1nA ac | |
| DC Voltage Resolution | 1 μV | |
| AC Voltage Resolution | 1V ac | |
| Maximum Frequency | 440Hz | |
| Resistance Measurement Accuracy | 0.02 % rdg + 0.003 % range | |
| Minimum Operating Temperature | 0°C | |
| Height | 88mm | |
| Width | 217mm | |
| Weight | 2.1kg | |
| Series | 8808A | |
| Standards/Approvals | UL 61010-1:2004, EN 61010-1:2001, AN/CSA C22.2, ANSI/ISA 61010-1 (S82.02.01):2004 | |
| Length | 297mm | |
| Safety Category Level | Joint, Connector Bracket | |
| Safety Category Voltage | 1000V ac | |
| Calibrated | UKAS | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke calibration | ||
Product Type Multimeter | ||
Multimeter Type Bench | ||
Display Type Digital | ||
Resistance Resolution 1mΩ | ||
Model Number 8808A/SU | ||
Functions Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Frequency, Resistance, Temperature | ||
Maximum AC Voltage Measurement 750V ac | ||
Maximum AC Current Measurement 10A ac | ||
Maximum DC Current Measurement 10A dc | ||
Maximum Resistance Measurement 100mΩ | ||
Maximum DC Voltage Measurement 1kV dc | ||
True RMS Yes | ||
DC Voltage Accuracy ±0.015 % rdg + 0.003 | ||
DC Current Accuracy 0.02 % rdg | ||
AC Voltage Accuracy ±0.2 % rdg | ||
AC Current Accuracy ±0.3 % rdg | ||
AC Current Resolution 100μA ac | ||
DC Current Resolution 1nA ac | ||
DC Voltage Resolution 1 μV | ||
AC Voltage Resolution 1V ac | ||
Maximum Frequency 440Hz | ||
Resistance Measurement Accuracy 0.02 % rdg + 0.003 % range | ||
Minimum Operating Temperature 0°C | ||
Height 88mm | ||
Width 217mm | ||
Weight 2.1kg | ||
Series 8808A | ||
Standards/Approvals UL 61010-1:2004, EN 61010-1:2001, AN/CSA C22.2, ANSI/ISA 61010-1 (S82.02.01):2004 | ||
Length 297mm | ||
Safety Category Level Joint, Connector Bracket | ||
Safety Category Voltage 1000V ac | ||
Calibrated UKAS | ||
- Land van herkomst:
- CN
Fluke 8808A Series Multimeter, 1000V Safety Category Voltage, 10A Maximum DC Current Measurement - FLUKE 8808A/SU 240V
Features and Benefits:
• True RMS measurement ensures accurate AC waveform assessment
• Maximum DC voltage 1000V supports high‑voltage testing
• Resistance range to 100 mΩ enables low‑resistance diagnostics
• AC/DC current capability up to 10A handles power measurements
• DC resolution 1 μV reveals very small voltage changes
Applications
• Ideal for calibration benches requiring high‑accuracy readings
• Used for power‑supply verification up to 1000V DC
• Can be used for low‑resistance contact testing and shunt checks
• Used with thermal sensors for temperature‑related measurements
What measurement functions does it provide beyond volts and amps?
How does it perform with AC signals of varying shapes?
What is the maximum frequency it can measure?
What safety credentials does the instrument meet for high‑voltage work?
Gerelateerde Links
- Fluke calibration 8808A/SU Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 1 kV ac, RSCAL Calibrated
- Fluke calibration 8808A Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac, UKAS Calibrated
- Fluke calibration 8808A Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac, RSCAL Calibrated
- Fluke calibration 8808A/SU Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 1 kV ac
- Fluke calibration 8808A Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac
- Fluke calibration 8808A/TL 240V Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac, RSCAL Calibrated
- Fluke calibration 8808A/TL 240V Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac, UKAS Calibrated
- Fluke calibration 8808A/TL 240V Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac