Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 2mA to 500mA, 20.4 → 26.4 V dc, 26.4V ac
- RS-stocknr.:
- 111-3090
- Fabrikantnummer:
- K8DT-AS1TD
- Fabrikant:
- Omron
Subtotaal (1 eenheid)*
€ 118,07
(excl. BTW)
€ 142,86
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Tijdelijk niet op voorraad
- Verzending vanaf 12 november 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 118,07 |
*prijsindicatie
- RS-stocknr.:
- 111-3090
- Fabrikantnummer:
- K8DT-AS1TD
- Fabrikant:
- Omron
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Omron | |
| Product Type | Monitoring Relay | |
| Electrical Phase | 1 | |
| Contact Configuration | SPST | |
| Mount Type | DIN Rail | |
| Minimum Current Sensed | 2mA | |
| Maximum Current Sensed | 500mA | |
| Power Consumption | 1.8VA | |
| Current Sensitivity | Overcurrent, Undercurrent | |
| Terminal Type | Push-in | |
| IP Rating | IP20 | |
| Time Delay | 250 ms | |
| Minimum Operating Temperature | -20°C | |
| Supply DC Voltage | 20.4 → 26.4 V dc | |
| Relay Contact Current | 2, 500mA | |
| Supply AC Voltage | 26.4V ac | |
| Maximum Operating Temperature | 60°C | |
| Standards/Approvals | EN 60947-5-1, RoHS, UL 60947-5-1 | |
| Width | 17.5mm | |
| Series | K8DT-AS | |
| Length | 90mm | |
| Height | 90mm | |
| Alles selecteren | ||
|---|---|---|
Merk Omron | ||
Product Type Monitoring Relay | ||
Electrical Phase 1 | ||
Contact Configuration SPST | ||
Mount Type DIN Rail | ||
Minimum Current Sensed 2mA | ||
Maximum Current Sensed 500mA | ||
Power Consumption 1.8VA | ||
Current Sensitivity Overcurrent, Undercurrent | ||
Terminal Type Push-in | ||
IP Rating IP20 | ||
Time Delay 250 ms | ||
Minimum Operating Temperature -20°C | ||
Supply DC Voltage 20.4 → 26.4 V dc | ||
Relay Contact Current 2, 500mA | ||
Supply AC Voltage 26.4V ac | ||
Maximum Operating Temperature 60°C | ||
Standards/Approvals EN 60947-5-1, RoHS, UL 60947-5-1 | ||
Width 17.5mm | ||
Series K8DT-AS | ||
Length 90mm | ||
Height 90mm | ||
- Land van herkomst:
- CN
Omron K8DT-AS Series Monitoring Relay, 20.4-26.4V Supply Voltage, 250ms Time Delay - K8DT-AS1TD
This monitoring relay provides compact, DIN-rail-mounted detection and signalling of current deviations in single-phase systems. It operates from low-voltage AC or DC supplies and responds to both excessive and insufficient current to protect equipment and trigger control logic in automation and electrical installations.
Features and Benefits:
• Detects overcurrent and undercurrent to prevent system faults
• Switches SPST contacts for simple on/off control integration
• Accepts 20.4 to 26.4V AC/DC supply for flexible power options
• Senses currents from 2 mA up to 500 mA for fine resolution
• 250 MS time delay to avoid nuisance trips from transients
• Push-in terminals speed installation and wiring changes
• Switches SPST contacts for simple on/off control integration
• Accepts 20.4 to 26.4V AC/DC supply for flexible power options
• Senses currents from 2 mA up to 500 mA for fine resolution
• 250 MS time delay to avoid nuisance trips from transients
• Push-in terminals speed installation and wiring changes
Applications
• Suitable for motor load monitoring to identify stalled conditions
• Ideal for conveyor systems requiring phase-limited current supervision
• Used with control panels for process automation alarm signalling
• Can be used for monitoring current draw on single-phase pumps
• Suitable for retrofit protection on small machinery in workshops
• Ideal for conveyor systems requiring phase-limited current supervision
• Used with control panels for process automation alarm signalling
• Can be used for monitoring current draw on single-phase pumps
• Suitable for retrofit protection on small machinery in workshops
What Terminal arrangement is provided for quick wiring?
It uses push-in type connections that allow tool-free conductor insertion and secure contact retention for efficient assembly.
What environmental limits should be observed during installation?
The unit is designed to operate between -20°C and 60°C and has IP20 ingress protection, so it requires an enclosed control cabinet in dusty or humid locations.
How does the relay indicate or act when current thresholds are crossed?
A single-pole single-throw contact changes state when measured current falls below or exceeds set limits, enabling external alarms or PLC inputs to respond.
What mounting method is required for panel integration?
The device clips onto a standard DIN rail for straightforward mounting within electrical enclosures.
What electrical phase and power consumption characteristics apply?
It monitors single-phase systems and consumes 1.8 VA during operation.
Note
K8DT-AS allow use in either overcurrent or undercurrent mode.
K8DT-AW allow overcurrent and undercurrent monitoring simultaneously
K8DT-AW allow overcurrent and undercurrent monitoring simultaneously
Standards
EN 60947-5-1, UL 60947-5-1, IP 20 Terminals
Gerelateerde Links
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 2mA to 500mA, 0V ac
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 2mA to 500mA, 0 V ac, 0V ac
- Omron Monitoring Relay, 1 Phase, SPDT, DIN Rail, 2mA to 500mA, 0 V ac, 0V ac
- Omron Monitoring Relay, 1 Phase, SPDT, DIN Rail, 2mA to 500mA, 0V ac
- Omron Monitoring Relay, 1 Phase, SPDT, DIN Rail, 2mA to 500mA, 24 V dc, 0V ac
- Omron Monitoring Relay, 3 Phase, Screw, DIN Rail, 500mA to 2mA, 100V ac, 240 V ac
- Omron Monitoring Relay, SPST, DIN Rail, Monitoring: 0 °C to 999 °C 0V ac
- Omron Monitoring Relay, SPST, DIN Rail, Monitoring: 0 °C to 999 °C, 0 V ac 0V ac