Omron DIN Rail Timer Relay, 4-Contact, 240 to 440 V ac 240V ac, 440 V ac, 1 to 120 s, 1-Function, DPDT Switch
- RS-stocknr.:
- 264-1636
- Fabrikantnummer:
- H3DK-GE 240-440VAC
- Fabrikant:
- Omron
Subtotaal (1 eenheid)*
€ 85,80
(excl. BTW)
€ 103,82
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Op voorraad
- Plus verzending 4 stuk(s) vanaf 11 mei 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 85,80 |
*prijsindicatie
- RS-stocknr.:
- 264-1636
- Fabrikantnummer:
- H3DK-GE 240-440VAC
- Fabrikant:
- Omron
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Omron | |
| Product Type | Timer Relay | |
| Mount Type | DIN Rail | |
| Time Range | 1 to 120 s | |
| Number of Contacts | 4 | |
| Number of Timer Functions | 1 | |
| Contact Configuration | DPDT | |
| Supply AC Voltage | 240, 440V ac | |
| Contact Current | 5A | |
| Supply DC Voltage | 240 to 440 V ac | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 55°C | |
| Terminal Type | Screw | |
| Standards/Approvals | cURus (UL 508 CSA C22.2 No. 14), EN 50274, EN 61812-1, IEC 60664-1 4 kV/2 | |
| Alles selecteren | ||
|---|---|---|
Merk Omron | ||
Product Type Timer Relay | ||
Mount Type DIN Rail | ||
Time Range 1 to 120 s | ||
Number of Contacts 4 | ||
Number of Timer Functions 1 | ||
Contact Configuration DPDT | ||
Supply AC Voltage 240, 440V ac | ||
Contact Current 5A | ||
Supply DC Voltage 240 to 440 V ac | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 55°C | ||
Terminal Type Screw | ||
Standards/Approvals cURus (UL 508 CSA C22.2 No. 14), EN 50274, EN 61812-1, IEC 60664-1 4 kV/2 | ||
Omron Timer Relay, 240/440V Supply Voltage, 1 to 120s Time Range - H3DK-GE 240-440VAC
This timer relay provides time-delay control for industrial automation and electrical systems, operating from a high-voltage AC supply and mounted on standard DIN rail. It is designed to control switching sequences in machinery and process equipment where adjustable delay timing is required, and connects via screw terminals for fixed wiring in control panels.
Features and Benefits:
• DPDT contact arrangement enabling dual-circuit switching capability
• 5A contact rating suitable for moderate load switching
• Time span adjustable from 1 to 120 s for flexible delay settings
• DIN rail mounting for straightforward panel integration
• Screw Terminal connections for secure, maintenance-friendly wiring
• Rated for operation between -20°C and 55°C to suit varied environments
• 5A contact rating suitable for moderate load switching
• Time span adjustable from 1 to 120 s for flexible delay settings
• DIN rail mounting for straightforward panel integration
• Screw Terminal connections for secure, maintenance-friendly wiring
• Rated for operation between -20°C and 55°C to suit varied environments
Applications
• Suitable for timing interlocks in production machinery control panels
• Ideal for staged motor starting in conveyor and drive systems
• Used with safety and signalling circuits requiring delayed switching
• Can be used for sequence timing in building services automation
• Suitable for replacing time-delay relays in retrofit control systems
• Ideal for staged motor starting in conveyor and drive systems
• Used with safety and signalling circuits requiring delayed switching
• Can be used for sequence timing in building services automation
• Suitable for replacing time-delay relays in retrofit control systems
What contact configuration does it provide for circuit control?
It uses a double-pole double-throw configuration, allowing two independent circuits to be switched simultaneously.
How is the device fixed inside an electrical enclosure?
It is designed for DIN rail installation, enabling Rapid Snap-on mounting and removal without additional brackets.
What Terminal type is provided for field wiring?
Termination is via screw-type terminals that provide firm conductor retention for repeated installations.
What standards relate to its electrical clearance performance?
It complies with IEC requirements for reinforced insulation clearances rated to the specified test level for surge withstand.
Gerelateerde Links
- Omron DIN Rail Timer Relay, 2-Contact, 24 to 240 V ac/dc 24V ac, 240 V ac, 1 to 120 s, 1-Function, DPDT Switch
- Omron H3DK Series DIN Rail Timer Relay, 1-Contact, 12 to to 240 V dc 200V ac, 240 V ac, 1 to 12, 10 to 120 s, 1-Function
- Omron H3DK Series DIN Rail Timer Relay, 240 V ac 240V ac, 0.1 to 12 s, 1-Function, SPDT Switch Configuration
- Omron H3DK Series DIN Rail Timer Relay, 1-Contact, 12 to to 240 V dc 12V ac, 0.1 s to 1200 h, Multifunction-Function,
- Omron H3DK Series DIN Rail Timer Relay, 2-Contact, 12 to to 240 V dc 12V ac, 0.1 s to 1200 h, Multifunction-Function,
- Omron H3DK Series DIN Rail Timer Relay, 2-Contact, 24 to 240 V dc 100V ac, 120 V ac, 1 to 120 s, Multifunction-Function,
- Siemens 3RP25 Series DIN Rail Timer Relay, 2-Contact 400V ac, 440 V ac, 0.05 s to 100 h, Multifunction-Function, DPDT
- Omron DIN Rail Timer Relay, 2-Contact, 24 to 240 V ac/dc 24V ac, 240 V ac, 0.1 to 43200 s, Multifunction-Function, SPDT