Omron H3DK Series DIN Rail Timer Relay, 2-Contact, 24 to 240 V dc 100V ac, 120 V ac, 1 to 120 s, Multifunction-Function,
- RS-stocknr.:
- 177-0082
- Fabrikantnummer:
- H3DK-HCL AC100-120
- Fabrikant:
- Omron
Subtotaal (1 eenheid)*
€ 87,16
(excl. BTW)
€ 105,46
(incl. BTW)
Informatie over voorraden is momenteel niet toegankelijk - Controleer het later nog eens opnieuw
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 87,16 |
*prijsindicatie
- RS-stocknr.:
- 177-0082
- Fabrikantnummer:
- H3DK-HCL AC100-120
- Fabrikant:
- Omron
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Omron | |
| Product Type | Timer Relay | |
| Mount Type | DIN Rail | |
| Function | Valve, Power Off Delay, Timer | |
| Time Range | 1 to 120 s | |
| Number of Contacts | 2 | |
| Switching Voltage | 250V ac | |
| Number of Timer Functions | Multifunction | |
| Contact Configuration | SPDT | |
| IP Rating | IP20, IP30 | |
| Supply DC Voltage | 24 to 240 V dc | |
| Contact Current | 5A | |
| Minimum Operating Temperature | -20°C | |
| Supply AC Voltage | 100, 120V ac | |
| Maximum Operating Temperature | 55°C | |
| Terminal Type | Screw | |
| Height | 100mm | |
| Length | 22.5mm | |
| Standards/Approvals | UL 508, CSA C22.2 No. 14, LR, EN 50274, EN 61812-1, IEC 60664-1, CE, CCC | |
| Width | 79mm | |
| Series | H3DK | |
| Alles selecteren | ||
|---|---|---|
Merk Omron | ||
Product Type Timer Relay | ||
Mount Type DIN Rail | ||
Function Valve, Power Off Delay, Timer | ||
Time Range 1 to 120 s | ||
Number of Contacts 2 | ||
Switching Voltage 250V ac | ||
Number of Timer Functions Multifunction | ||
Contact Configuration SPDT | ||
IP Rating IP20, IP30 | ||
Supply DC Voltage 24 to 240 V dc | ||
Contact Current 5A | ||
Minimum Operating Temperature -20°C | ||
Supply AC Voltage 100, 120V ac | ||
Maximum Operating Temperature 55°C | ||
Terminal Type Screw | ||
Height 100mm | ||
Length 22.5mm | ||
Standards/Approvals UL 508, CSA C22.2 No. 14, LR, EN 50274, EN 61812-1, IEC 60664-1, CE, CCC | ||
Width 79mm | ||
Series H3DK | ||
- Land van herkomst:
- ID
Omron H3DK Series Timer Relay, 1 to 120s Time Range, SPDT Contact Configuration - H3DK-HCL AC100-120
This timer relay provides configurable time-delay functionality for industrial control systems, enabling delayed switching and valve power-off sequencing within automation panels. It is intended for DIN-rail mounting and suits electrical, electronic and mechanical installations requiring Compact time control and a changeover contact for load switching.
Features and Benefits:
• SPDT contact rated for 5A delivers direct load-switching capability
• Multifunction timing covers 1 to 120 s for versatile delay selection
• Accepts 100/120V AC or 24–240V DC supplies for flexible power options
• Screw terminals ensure secure, serviceable wiring connections
• 250V AC switching voltage supports common AC load requirements
• UL508, CSA, EN and IEC standards certification confirms industrial acceptability
• Multifunction timing covers 1 to 120 s for versatile delay selection
• Accepts 100/120V AC or 24–240V DC supplies for flexible power options
• Screw terminals ensure secure, serviceable wiring connections
• 250V AC switching voltage supports common AC load requirements
• UL508, CSA, EN and IEC standards certification confirms industrial acceptability
Applications
• Suitable for valve power-off delay operations in pneumatic systems
• Ideal for pump and motor control panels requiring timed shut-off
• Used with PLCs for auxiliary timing and interlock sequences
• Can be used for machinery safety delays during stop procedures
• Ideal for pump and motor control panels requiring timed shut-off
• Used with PLCs for auxiliary timing and interlock sequences
• Can be used for machinery safety delays during stop procedures
What mounting method is required for panel installation?
It clips onto a standard DIN rail to allow Rapid fitting and replacement within control cabinets.
Which environmental limits affect placement inside enclosures?
It operates between -20 °C and 55 °C, so enclosures should maintain ambient temperatures within this range.
How many switching contacts are available for control circuits?
There are two contacts arranged as a single changeover contact providing one switching output.
What protection ratings describe suitability for interior installations?
The product has IP20 and IP30 ratings, indicating protection against finger access and limited solid ingress for indoor use.
How is wiring secured and maintained during service?
Terminals are screw type to permit firm conductor clamping and straightforward retightening during maintenance.
Gerelateerde Links
- Omron H3DK Series DIN Rail Timer Relay, 1-Contact, 12 to to 240 V dc 100V ac, 120 V ac, 1 to 12 s, 0.1 to 1.2 s,
- Omron H3DK Series DIN Rail Timer Relay, 2-Contact, 12 V dc, 1 to 120 s, Multifunction-Function, SPDT Switch
- Omron H3YN Series Timer Relay, 4-Contact, 100 to 120 V ac 100V ac, 120 V ac, 0.1 to 600 min, Multifunction-Function,
- Omron H3CR Series DIN Rail Timer Relay, 1-Contact, 100 to 125 V dc 100V ac, 120 V ac, 0.5 to 120 s,
- Omron H3YN Series Timer Relay, 4-Contact, 100 to 120 V ac 100V ac, 120 V ac, 0.1 to 600 s, Multifunction-Function, 4PDT
- Omron H3YN Series Timer Relay, 4-Contact, 100 to 120 V ac 100V ac, 120 V ac, 0.1 to 600 s, Multifunction-Function, DPDT
- Omron H3DK Series DIN Rail Timer Relay, 1-Contact, 12 to to 240 V dc 12V ac, 0.1 s to 1200 h, Multifunction-Function,
- Omron H3DK Series DIN Rail Timer Relay, 2-Contact, 12 to to 240 V dc 12V ac, 0.1 s to 1200 h, Multifunction-Function,