ETA Thermal Circuit Breaker / Switch - 2 Pole Snap In, 16A Current Rating
- RS-stocknr.:
- 286-0753
- Fabrikantnummer:
- 3120-F551-H7T1-W14DB4-16A
- Fabrikant:
- ETA
Afbeelding representeert productcategorie
Niet beschikbaar
RS heeft dit product niet meer op voorraad.
Alternatieven
Dit product is momenteel niet beschikbaar. Hierbij onze aanbeveling voor mogelijke alternatieven.
la pièce
22,47 €
(excl. BTW)
27,19 €
(incl. BTW)
Per stuk
€ 15,92
(excl. BTW)
€ 19,26
(incl. BTW)
- RS-stocknr.:
- 286-0753
- Fabrikantnummer:
- 3120-F551-H7T1-W14DB4-16A
- Fabrikant:
- ETA
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ETA | |
| Current Rating | 16A | |
| Number of Poles | 2 | |
| Width | 25mm | |
| Reset Actuator Type | Rocker | |
| Mounting Style | Snap In | |
| Alles selecteren | ||
|---|---|---|
Merk ETA | ||
Current Rating 16A | ||
Number of Poles 2 | ||
Width 25mm | ||
Reset Actuator Type Rocker | ||
Mounting Style Snap In | ||
CBE, 1 Pole Sensing, 2 Pole Switching and Illuminating, 3120 Series
IEC Classification S/TO (with module, S/TM), Illuminated switch and circuit breaker combined units which offer both mechanical and visual indication of contact position and power status. Available in red or green illumination (suitable for medical applications).
H7T1 Variant units can also be converted to thermal magnetic type, for faster response to gross overloads, or to no volt release products to protect sensitive equipment.
H7T1 Variant units can also be converted to thermal magnetic type, for faster response to gross overloads, or to no volt release products to protect sensitive equipment.
Depth behind panel: 43mm
Basic tripping time at 2xIN 20-30 seconds
Circuit protection designed for equipment, sub-systems and components
Basic tripping time at 2xIN 20-30 seconds
Circuit protection designed for equipment, sub-systems and components
Approvals
UL, CSA, VDE, BV
Approvals
UL. CSA, VDE
Thermal Magnetic Convertible
All CBEs have blade terminals and have an insulation resistance greater than 100MΩ (MegaOhms).
Gerelateerde Links
- ETA Thermal Circuit Breaker - 3120 2 Pole 250V Voltage Rating Snap In, 16A Current Rating
- ETA Thermal Circuit Breaker - 3120-N 2 Pole 50 V DC, 240 V AC Voltage Rating, 16A Current Rating
- ETA Thermal Circuit Breaker - 3120-N 5 Pole 50 V DC, 240 V AC Voltage Rating, 16A Current Rating
- ETA Thermal Circuit Breaker - 3120-F 2 Pole 240V Voltage Rating Snap In, 12A Current Rating
- ETA Thermal Circuit Breaker - 3120-N 2 Pole 50 V DC, 240 V AC Voltage Rating, 1.5A Current Rating
- ETA Thermal Circuit Breaker - 3120-N 2 Pole 50 V DC, 240 V AC Voltage Rating, 10A Current Rating
- ETA Thermal Circuit Breaker - 3120-N 5 Pole 50 V DC, 240 V AC Voltage Rating, 2.5A Current Rating
- ETA Thermal Circuit Breaker - 3120-N 5 Pole 50 V DC, 240 V AC Voltage Rating, 12A Current Rating