Phoenix Contact MACX MCR Series Signal Transducer, Current Input, Current Output, 18 → 31.2V Supply
- RS-stocknr.:
- 518-131
- Fabrikantnummer:
- 1290776
- Fabrikant:
- Phoenix Contact
Subtotaal (1 eenheid)*
€ 454,93
(excl. BTW)
€ 550,47
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Tijdelijk niet op voorraad
- Verzending vanaf 29 januari 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 454,93 |
*prijsindicatie
- RS-stocknr.:
- 518-131
- Fabrikantnummer:
- 1290776
- Fabrikant:
- Phoenix Contact
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Phoenix Contact | |
| Module Type | Signal Transducer | |
| Input Signal Type | Current | |
| Output Signal Type | Current | |
| Input Range | 4 → 20mA | |
| Output Range | 4 → 20mA | |
| Supply Voltage | 18 → 31.2V | |
| Series | MACX MCR | |
| Alles selecteren | ||
|---|---|---|
Merk Phoenix Contact | ||
Module Type Signal Transducer | ||
Input Signal Type Current | ||
Output Signal Type Current | ||
Input Range 4 → 20mA | ||
Output Range 4 → 20mA | ||
Supply Voltage 18 → 31.2V | ||
Series MACX MCR | ||
- Land van herkomst:
- DE
The Phoenix Contact power/input isolating amplifier designed to ensure precise signal transmission and robust protection in hazardous environments. Ideal for use in demanding applications, this device supports 2, 3, and 4 conductor measuring transducers while maintaining exceptional HART transparency. With its compact design, it facilitates seamless integration into control cabinet installations, enabling efficient monitoring and control of processes. The amplifier features advanced electrical isolation and safety integrity level (SIL) 2 classification, making it a reliable choice for professionals seeking performance without compromising safety.
Compact design allows for efficient space utilisation in control cabinets
Supports multiple measuring transducer configurations for versatile application
HART transparency ensures compatibility with a wide range of HART enabled devices
Configurable limit value outputs provide flexible operation and monitoring
Robust electrical isolation safeguards against interference and electrical hazards
SIL 2 rating ensures compliance with rigorous safety standards
Wide supply voltage range accommodates various industrial power setups
Temperature compensation enhances measurement accuracy in varying conditions
Supports multiple measuring transducer configurations for versatile application
HART transparency ensures compatibility with a wide range of HART enabled devices
Configurable limit value outputs provide flexible operation and monitoring
Robust electrical isolation safeguards against interference and electrical hazards
SIL 2 rating ensures compliance with rigorous safety standards
Wide supply voltage range accommodates various industrial power setups
Temperature compensation enhances measurement accuracy in varying conditions
Gerelateerde Links
- Phoenix Contact MACX MCR Series Signal Transducer, Current Input, Current Output, 18 → 31.2V Supply
- Phoenix Contact Signal Transducer, Current Input, Current Output, 18 → 31.2V Supply, ATEX, IECEx
- Weidmuller ACT20P Series Signal Transducer, Current Input, Current Output, 31.2V Supply
- Phoenix Contact MACX-MCR Series Frequency Transducer, Frequency Input, Current Output, 24V dc Supply
- Phoenix Contact MACX MCR-SL-CAC-5-I Series Current Measuring Transducer, 24V dc Supply
- Phoenix Contact MACX MCR Series Temperature Transducer, 24V dc Supply
- Phoenix Contact MACX MCR Series Signal Conditioner, Current Input, Current Output, <30.5V Supply, ATEX
- Phoenix Contact MACX MCR Series Signal Conditioner, Current, Voltage Input, Current Output, 8 → 30V dc Supply,
