Phoenix Contact MACX MCR Series Signal Conditioner, Current, Voltage Input, Current Output, 8 → 30V dc Supply,
- RS-stocknr.:
- 196-0434
- Fabrikantnummer:
- 2902063
- Fabrikant:
- Phoenix Contact
Subtotaal (1 eenheid)*
€ 187,94
(excl. BTW)
€ 227,41
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Op voorraad
- Plus verzending 2 stuk(s) vanaf 15 december 2025
- Plus verzending 6 stuk(s) vanaf 15 december 2025
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 187,94 |
*prijsindicatie
- RS-stocknr.:
- 196-0434
- Fabrikantnummer:
- 2902063
- Fabrikant:
- Phoenix Contact
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Phoenix Contact | |
| Module Type | Loop Powered Isolator | |
| Input Signal Type | Current, Voltage | |
| Output Signal Type | Current | |
| Input Range | 2 mA → 40 mA, 50 mV → 30V | |
| Output Range | 4 → 20mA | |
| Supply Voltage | 8 → 30V dc | |
| Hazardous Area Certification | ATEX | |
| Mounting Type | DIN Rail Mount | |
| Operating Temperature Range | -40 → +70°C | |
| Series | MACX MCR | |
| Minimum Operating Temperature | -40°C | |
| Signal Conditioner Function | Isolation | |
| Termination | Push-In | |
| Standards Met | UL | |
| Maximum Operating Temperature | +70°C | |
| Alles selecteren | ||
|---|---|---|
Merk Phoenix Contact | ||
Module Type Loop Powered Isolator | ||
Input Signal Type Current, Voltage | ||
Output Signal Type Current | ||
Input Range 2 mA → 40 mA, 50 mV → 30V | ||
Output Range 4 → 20mA | ||
Supply Voltage 8 → 30V dc | ||
Hazardous Area Certification ATEX | ||
Mounting Type DIN Rail Mount | ||
Operating Temperature Range -40 → +70°C | ||
Series MACX MCR | ||
Minimum Operating Temperature -40°C | ||
Signal Conditioner Function Isolation | ||
Termination Push-In | ||
Standards Met UL | ||
Maximum Operating Temperature +70°C | ||
- Land van herkomst:
- DE
Phoenix Contact Signal Conditioner, Output Loop-Powered 2-Way Isolator Type, 30V Maximum Input Voltage - MINI MCR-2-UI-I-OLP-PT - 2902063
Looking for a device that can convert electronic signals? Take charge with this Phoenix Contact signal conditioner. When supplied with inputs between 0 and 40mA, it manipulates them into outputs with a maximum current of 32mA. This lets you prepare your transmissions so they're easier to process later down the line in your network. For a fast and flexible setup, the unit uses a push-in method and is mountable in any position.
Humidity is no problem for this product, as it's built to withstand 5 to 95% RH. This makes it suitable for damp areas that experience high levels of non-condensing water vapour. Plus, its PBT housing is resistant to chemicals for a longer service life in heavy-duty applications. You can get an easy handle on the unit, without worrying about shocks, as it has an IP20 rating.
Humidity is no problem for this product, as it's built to withstand 5 to 95% RH. This makes it suitable for damp areas that experience high levels of non-condensing water vapour. Plus, its PBT housing is resistant to chemicals for a longer service life in heavy-duty applications. You can get an easy handle on the unit, without worrying about shocks, as it has an IP20 rating.
• Configurable input to allow for greater versatility
• Compact dimensions of 6.2 (W) x 110.5 (H) x 120.5mm (D) make this a space-saving component
• Broad operating temperature range between -40 and +70°C for use in challenging environments
• Overvoltage category II rating for protection from unplanned voltage surges
• Compact dimensions of 6.2 (W) x 110.5 (H) x 120.5mm (D) make this a space-saving component
• Broad operating temperature range between -40 and +70°C for use in challenging environments
• Overvoltage category II rating for protection from unplanned voltage surges
Output loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of unipolar and bipolar analog signals. Input configurable via DIP switch. Push-in connection technology, standard configuration. Output loop-powered 2-way isolator with plug-in connection technology for the electrical isolation, conversion, and filtering of analog signals. The output loop-powered isolator allows operation at an active analog input module. The device is supplied via the current loop of the controller. On the input side, standard analog signals and non-standard analog signals can be connected, ranging from 2 mA or 50 mV up to 40 mA or 30 V. These are converted to 4 mA ... 20 mA signals. You can configure the input signals via DIP switches. The measuring transducer supports NFC communication.
Gerelateerde Links
- Phoenix Contact MACX MCR Series Signal Conditioner, Current Input, Current Output, 19.2 → 30V dc Supply, ATEX,
- Phoenix Contact MACX MCR Series Signal Conditioner, Current Input, Current Output, 9.6 → 30V dc Supply, ATEX
- Phoenix Contact MACX MCR Series Signal Conditioner, Current Input, Current Output, 19.2 → 30V dc Supply, ATEX
- Phoenix Contact MACX MCR Series Signal Conditioner, Voltage Input, Voltage Output, 9.6 → 30V dc Supply, ATEX
- Phoenix Contact MACX MCR Series Signal Conditioner, Voltage Input, Current, Voltage Output, 24V dc Supply
- Phoenix Contact MACX MCR Series Signal Conditioner, Voltage Input, Current, Voltage Output, 24V dc Supply, ATEX
- Phoenix Contact MACX MCR Series Signal Conditioner, Current Input, Current Output, <30.5V Supply, ATEX
- Phoenix Contact MACX MCR Series Signal Conditioner, Transistor Output, 19.2 → 30V dc Supply, ATEX, IECEx