Eaton xEffect Series Residual Current Circuit Breaker, 63A, 4-Pole, 300 mA, Type F, 500 A 415V ac
- RS-stocknr.:
- 248-943
- Fabrikantnummer:
- 187422 FRCMM-63/4/03-G/F
- Fabrikant:
- Eaton
Subtotaal (1 eenheid)*
€ 403,00
(excl. BTW)
€ 487,63
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Voorradig bij de fabrikant
- Klaar voor verzending vanaf 18 mei 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 403,00 |
*prijsindicatie
- RS-stocknr.:
- 248-943
- Fabrikantnummer:
- 187422 FRCMM-63/4/03-G/F
- Fabrikant:
- Eaton
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Eaton | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 63A | |
| Number of Poles | 4 | |
| Range | FRCmM | |
| Series | xEffect | |
| Trip Sensitivity | 300mA | |
| Tripping Characteristics | Type F | |
| Mount Type | DIN Rail | |
| Standards/Approvals | IEC/EN 61008, RoHS conform, IEC 61373, EN45545-2, IEC/EN 62423, IEC/EN 61439, IEC/EN 60715 | |
| Terminal Type | Twin-Purpose Terminal | |
| Width | 70mm | |
| Depth | 76mm | |
| Height | 80mm | |
| Breaking Capacity | 500A | |
| Rated AC Voltage | 415V ac | |
| Break Time | 10 ms | |
| Earth Leakage Protection Type | F | |
| Tripping Mechanism | Residual Current | |
| Alles selecteren | ||
|---|---|---|
Merk Eaton | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 63A | ||
Number of Poles 4 | ||
Range FRCmM | ||
Series xEffect | ||
Trip Sensitivity 300mA | ||
Tripping Characteristics Type F | ||
Mount Type DIN Rail | ||
Standards/Approvals IEC/EN 61008, RoHS conform, IEC 61373, EN45545-2, IEC/EN 62423, IEC/EN 61439, IEC/EN 60715 | ||
Terminal Type Twin-Purpose Terminal | ||
Width 70mm | ||
Depth 76mm | ||
Height 80mm | ||
Breaking Capacity 500A | ||
Rated AC Voltage 415V ac | ||
Break Time 10 ms | ||
Earth Leakage Protection Type F | ||
Tripping Mechanism Residual Current | ||
- Land van herkomst:
- RS
The Eaton Moeller series xEffect - FRCmM Type F RCCB is a cutting-edge residual current circuit breaker designed for both industrial and advanced commercial applications. This product not only ensures superior electrical safety but also enhances operational efficiency with its robust features. Engineered to operate seamlessly at voltage ratings of 240 V AC and 415 V AC, this RCCB guarantees reliable performance under varying conditions. The four-pole design provides optimal circuit protection, ensuring a high degree of safety in dynamic environments. With an impressive fault current rating and a rapid tripping time, this device effectively mitigates electrical risks, safeguarding both equipment and personnel. Additionally, the unit boasts a stylish, compact design, ensuring it fits both new installations and retrofit applications with ease.
Ensures compliance with RoHS standards for environmental safety
Delivers a high short-circuit rating for enhanced reliability
Equipped with quick attachment mechanisms for efficient installation
Designed to operate in a wide ambient temperature range from -25 °C to 40 °C
Features finger and hand touch safety for added protection
Meets stringent corrosion resistance requirements to ensure durability
Offers an impressive lifespan with up to 20,000 mechanical operations
Provides clear status indication through a white/blue indicator design
Gerelateerde Links
- Eaton xEffect - FRCmM Series Residual Current Circuit Breaker, 63 A, 4-Pole, 300 mA, 10 kA 415 V ac
- Eaton xEffect - FRCmM Series Residual Current Circuit Breaker, 63 A, 4-Pole, 300 mA, Type A, 10 kA 415 V ac
- Eaton xEffect Series Residual Current Circuit Breaker, 63 A, 4-Pole, 30 mA, Type F, 630 A 415 V ac
- Eaton xEffect - FRCmM Series Residual Current Circuit Breaker, 63 A, 4-Pole, 300 mA, Type S/A, 10 kA 415 V ac
- Eaton xEffect Series Residual Current Circuit Breaker, 25 A, 4-Pole, 300 mA, Type F, 500 A 415 V ac
- Eaton xEffect Series Residual Current Circuit Breaker, 16 A, 4-Pole, 300 mA, Type F, 500 A 415 V ac
- Eaton xEffect Series Residual Current Circuit Breaker, 40 A, 4-Pole, 300 mA, Type F, 500 A 415 V ac
- Eaton xEffect Series Residual Current Circuit Breaker, 16 A, 4-Pole, 300 mA, Type F, 10 kA 415 V ac