Eaton xEffect Series Residual Current Circuit Breaker, 63A, 2-Pole, 300 mA, Type F, 630 A 240V ac
- RS-stocknr.:
- 248-939
- Fabrikantnummer:
- 187398 FRCMM-63/2/03-S/F
- Fabrikant:
- Eaton
Subtotaal (1 eenheid)*
€ 403,00
(excl. BTW)
€ 487,63
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Voorradig bij de fabrikant
- Klaar voor verzending vanaf 02 juni 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 403,00 |
*prijsindicatie
- RS-stocknr.:
- 248-939
- Fabrikantnummer:
- 187398 FRCMM-63/2/03-S/F
- Fabrikant:
- Eaton
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Eaton | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 63A | |
| Number of Poles | 2 | |
| Series | xEffect | |
| Range | FRCmM | |
| Trip Sensitivity | 300mA | |
| Mount Type | DIN Rail | |
| Tripping Characteristics | Type F | |
| Standards/Approvals | IEC/EN 62423, IEC/EN 61008, EN45545-2, IEC/EN 61439, IEC 61373 | |
| Terminal Type | Twin-Purpose Terminal | |
| Depth | 76mm | |
| Height | 80mm | |
| Width | 35mm | |
| Breaking Capacity | 630A | |
| Earth Leakage Protection Type | F | |
| Break Time | 40 ms | |
| Rated AC Voltage | 240V ac | |
| Alles selecteren | ||
|---|---|---|
Merk Eaton | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 63A | ||
Number of Poles 2 | ||
Series xEffect | ||
Range FRCmM | ||
Trip Sensitivity 300mA | ||
Mount Type DIN Rail | ||
Tripping Characteristics Type F | ||
Standards/Approvals IEC/EN 62423, IEC/EN 61008, EN45545-2, IEC/EN 61439, IEC 61373 | ||
Terminal Type Twin-Purpose Terminal | ||
Depth 76mm | ||
Height 80mm | ||
Width 35mm | ||
Breaking Capacity 630A | ||
Earth Leakage Protection Type F | ||
Break Time 40 ms | ||
Rated AC Voltage 240V ac | ||
- Land van herkomst:
- RS
The Eaton Moeller series xEffect - FRCmM Type F RCCB is an advanced residual current circuit breaker designed for robust industrial and commercial applications. Engineered to provide exceptional protection, this device monitors residual currents, swiftly disconnecting the electrical supply to prevent hazardous situations. With a compact design, it seamlessly fits into a varied range of switchgear configurations. The product stands out with its high fault current rating and selective switch-off capabilities, ensuring reliability in demanding environments. Compliance with stringent international standards makes it a trusted choice for enhancing electrical safety in any installation.
Provides optimal protection against electrical faults
Compact design ideal for diverse applications
Features a sensitive pulse-current response for enhanced safety
Designed for quick installation with DIN rail mounting
Offers high operational durability with extensive lifespan ratings
Ensures effective monitoring of electrical environments
Adaptable to a variety of mounting positions for user convenience
Includes twin-purpose terminals for versatile wiring options
Delivers compliance with international safety standards
Gerelateerde Links
- Eaton xEffect Series Residual Current Circuit Breaker, 63 A, 2-Pole, 300 mA, Type F, 630 A 250 V ac
- Eaton xEffect Series Residual Current Circuit Breaker, 63 A, 4-Pole, 30 mA, Type F, 630 A 415 V ac
- Eaton xEffect Series Residual Current Circuit Breaker, 63 A, 4-Pole, 300 mA, Type F, 500 A 415 V ac
- Eaton xEffect - FRCmM Series Residual Current Circuit Breaker, 63 A, 2-Pole, 30 mA, Type A, 630 A 121 V ac
- Eaton xEffect - FRCmM-NA Series Residual Current Circuit Breaker, 63 A, 2-Pole, 300 mA 305 V ac
- Eaton xEffect - FRCmM-NA Series Residual Current Circuit Breaker, 63 A, 2-Pole, 300 mA 132 V ac
- Eaton xEffect - FRCmM-NA Series Residual Current Circuit Breaker, 63 A, 2-Pole, 300 mA, Type A 305 V ac
- Eaton xEffect Series Residual Current Circuit Breaker, 63 A, 2-Pole, 100 mA, Type F, 10 kA 240 V ac