Schneider Electric Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 1-Pole, 30 mA Trip
- RS-stocknr.:
- 790-9257
- Artikelnummer Distrelec:
- 304-02-117
- Fabrikantnummer:
- A9D11216
- Fabrikant:
- Schneider Electric
Subtotaal (1 eenheid)*
€ 201,64
(excl. BTW)
€ 243,98
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Tijdelijk niet op voorraad
- Verzending 5 stuk(s) vanaf 28 augustus 2026
- Plus verzending 35 stuk(s) vanaf 04 september 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 201,64 |
*prijsindicatie
- RS-stocknr.:
- 790-9257
- Artikelnummer Distrelec:
- 304-02-117
- Fabrikantnummer:
- A9D11216
- Fabrikant:
- Schneider Electric
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Schneider Electric | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Current Rating | 16A | |
| Range | Acti9 | |
| Series | Acti9 | |
| Number of Poles | 1 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type C | |
| Mount Type | DIN Rail | |
| Rated AC Voltage | 230V ac | |
| Terminal Type | Screw | |
| Earth Leakage Protection Type | Type A | |
| Width | 18mm | |
| Height | 85mm | |
| Depth | 64mm | |
| Application | Distribution | |
| Breaking Capacity | 10kA | |
| Standards/Approvals | RoHS | |
| Tripping Mechanism | Thermal Magnetic | |
| Reset Actuator Type | Toggle Switch | |
| Alles selecteren | ||
|---|---|---|
Merk Schneider Electric | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Current Rating 16A | ||
Range Acti9 | ||
Series Acti9 | ||
Number of Poles 1 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type C | ||
Mount Type DIN Rail | ||
Rated AC Voltage 230V ac | ||
Terminal Type Screw | ||
Earth Leakage Protection Type Type A | ||
Width 18mm | ||
Height 85mm | ||
Depth 64mm | ||
Application Distribution | ||
Breaking Capacity 10kA | ||
Standards/Approvals RoHS | ||
Tripping Mechanism Thermal Magnetic | ||
Reset Actuator Type Toggle Switch | ||
Schneider Electric RCBO, Padlockable, IP20 Rating - Acti 9 Series - A9D11216
To triple the safety of your circuit, install this RCBO from Schneider Electric. By combining protection against short circuits, overcurrent and earth leakage, it keeps your equipment safe from potentially damaging faults. Thanks to its type-C tripping characteristics, it cuts out at 5 to 10 times its 16A current rating. This makes it suitable for systems with high inductive loads that are prone to short circuits, such as transformers. Thanks to its instantaneous earth-leakage protection, this unit's always on alert to ground faulty earth currents, keeping you safe from electric shocks.
Features & Benefits
• Padlockable design helps prevent tampering
• IP20 rating indicates it's protected against solid objects up to 12mm
• DIN rail mounting for easy installation
• Integrated contact position indicator for fast fault-finding
Applications
• Power stations
• Home appliances
• Warehouses and distribution centres
• Manufacturing industry
Can I reset this RCBO?
Yes, resetting this RCBO is quick and simple. Just flick the front-facing toggle switch downward, which reveals the green-coloured ON indicator strip.
How durable is this device?
Thanks to a mechanical durability rating of 20,000 cycles, you can be sure this RCBO stands up to repeated long-term use.
Gerelateerde Links
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 1-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 4-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 2-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 1-Pole, 300 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 3-Pole, 300 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 2-Pole, 300 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 1-Pole, 16000 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 3-Pole, 30 mA Trip