Schneider Electric Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 3-Pole, 30 mA Trip
- RS-stocknr.:
- 654-839
- Fabrikantnummer:
- A9DC3716
- Fabrikant:
- Schneider Electric
Subtotaal (1 eenheid)*
€ 213,07
(excl. BTW)
€ 257,81
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Op voorraad
- Plus verzending 3 stuk(s) vanaf 25 mei 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 213,07 |
*prijsindicatie
- RS-stocknr.:
- 654-839
- Fabrikantnummer:
- A9DC3716
- Fabrikant:
- Schneider Electric
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Schneider Electric | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Current Rating | 16A | |
| Series | ICV40N | |
| Number of Poles | 3 | |
| Range | Acti9 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type C | |
| Terminal Type | Screw Clamp | |
| Depth | 72mm | |
| Width | 18mm | |
| Height | 110mm | |
| Application | Distribution | |
| Standards/Approvals | IEC 61009-1, BS EN 61009-1, IEC 61009-2-2 | |
| Breaking Capacity | 10000A | |
| Alles selecteren | ||
|---|---|---|
Merk Schneider Electric | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Current Rating 16A | ||
Series ICV40N | ||
Number of Poles 3 | ||
Range Acti9 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type C | ||
Terminal Type Screw Clamp | ||
Depth 72mm | ||
Width 18mm | ||
Height 110mm | ||
Application Distribution | ||
Standards/Approvals IEC 61009-1, BS EN 61009-1, IEC 61009-2-2 | ||
Breaking Capacity 10000A | ||
- Land van herkomst:
- ES
The Schneider Electric Acti9 iCV40 is a modular residual current breaker with overcurrent protection (RCBO). It is a 3P+N circuit breaker with 3 protected poles, In rated current of 16A and C tripping curve. The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 6000A according EN/IEC 61009-2-1 standard. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. Its 2 unique Visitrip indicators reduce intervention time by showing the faulty circuit and identifying quickly the type of default. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance.
Dedicated to the small, medium and large buildings applications
VisiTrip offers a visible fault indicator for fast and optimized on-site servicing
VisiSafe offers a visible green strip with reinforced insulation for maintenance in better safety conditions
Gerelateerde Links
- Schneider Electric RCBO, 1-Pole, 30 mA Trip Sensitivity
- Schneider Electric RCBO, 3-Pole, 30 mA Trip Sensitivity
- Schneider Electric RCBO, 1-Pole, 100 mA Trip Sensitivity
- Schneider Electric RCBO, 16A Current Rating, 4-Pole, 30 mA Trip Sensitivity, Type B, Acti9 Range, A9d Range
- Schneider Electric RCBO, 32A Current Rating, 2-Pole, 30 mA Trip Sensitivity, Type C, Acti9 Range, iC60 Range
- Schneider Electric RCBO, 20A Current Rating, 2-Pole, 30 mA Trip Sensitivity, Type C, Acti9 Range, iC60 Range
- Hager RCBO, 30 mA Trip Sensitivity, Type C
- Schneider Electric, 30 mA Trip Sensitivity