Eaton Residual Current Circuit Breaker with Overload Protection, 10 A Current Rating, 1-Pole, 30 mA Trip Sensitivity,
- RS-stocknr.:
- 183-3543
- Fabrikantnummer:
- 236962 PXK-C10/1N/003-A
- Fabrikant:
- Eaton
Subtotaal (1 eenheid)*
€ 168,06
(excl. BTW)
€ 203,35
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Op voorraad
- Plus verzending 74 stuk(s) vanaf 02 maart 2026
- Plus verzending 27 stuk(s) vanaf 02 maart 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 168,06 |
*prijsindicatie
- RS-stocknr.:
- 183-3543
- Fabrikantnummer:
- 236962 PXK-C10/1N/003-A
- Fabrikant:
- Eaton
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Eaton | |
| Current Rating | 10 A | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Number of Poles | 1 | |
| Range | PXK | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 240 V ac | |
| Earth Leakage Protection Type | Type A | |
| Width | 2 mm | |
| Depth | 69.5mm | |
| Tripping Mechanism | Non-Delayed | |
| Breaking Capacity | 10kA | |
| Application | Commercial, Residential | |
| Standards/Approvals | IEC/EN 61009 | |
| Alles selecteren | ||
|---|---|---|
Merk Eaton | ||
Current Rating 10 A | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Number of Poles 1 | ||
Range PXK | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 240 V ac | ||
Earth Leakage Protection Type Type A | ||
Width 2 mm | ||
Depth 69.5mm | ||
Tripping Mechanism Non-Delayed | ||
Breaking Capacity 10kA | ||
Application Commercial, Residential | ||
Standards/Approvals IEC/EN 61009 | ||
- Land van herkomst:
- AT
Eaton Residual Current Circuit Breaker With Overcurrent Protection, 1+N Poles - PXK-C Series - PXK-C10/1N/003-A
Looking for a combined solution that detects and protects against overload and short circuits? This Eaton RCBO (residual current circuit breaker with overcurrent protection) combines RCB (residual current device) and MCB (miniature circuit breaker) functionality to protect against earth leakage as well as overcurrent. It interrupts and disconnects power supplies when it detects a fault, protecting operators from electric shocks and equipment from damage. Attach this unit to your industrial circuits to enhance workplace safety.
• Operating temperature range of -25°C to +40°C for use with devices in demanding indoor and outdoor settings
• Trip sensitivity of 30mA prevents risk of electric shocks
• Type-C tripping characteristics ensure the device triggers disconnect within 5 seconds after fault detection
Why is an RCBO better than a circuit breaker?
Circuit breakers only disconnect the flow of current after a fault occurs. An RCBO, such as this one from Eaton, incorporates a circuit breaker and an overcurrent protector, which automatically interrupt the power supply when detecting even slight imbalances on a circuit. By doing this, it prevents damage to equipment and injury caused by electrocution.
Note
Eaton formerly known as Moeller
Gerelateerde Links
- Eaton Residual Current Circuit Breaker with Overload Protection, 10 A Current Rating, 1-Pole, 300 mA Trip Sensitivity,
- Eaton Residual Current Circuit Breaker with Overload Protection, 32 A Current Rating, 1-Pole, 30 mA Trip Sensitivity,
- Eaton Residual Current Circuit Breaker with Overload Protection, 13 A Current Rating, 1-Pole, 30 mA Trip Sensitivity,
- Eaton Residual Current Circuit Breaker with Overload Protection, 6 A Current Rating, 1-Pole, 30 mA Trip Sensitivity,
- Eaton Residual Current Circuit Breaker with Overload Protection, 40 A Current Rating, 1-Pole, 30 mA Trip Sensitivity,
- Eaton Residual Current Circuit Breaker with Overload Protection, 10 A Current Rating, 1-Pole, 30 mA Trip Sensitivity,
- Eaton Residual Current Circuit Breaker with Overload Protection, 20 A Current Rating, 1-Pole, 30 mA Trip Sensitivity,
- Eaton Residual Current Circuit Breaker with Overload Protection, 25 A Current Rating, 1-Pole, 30 mA Trip Sensitivity,