Eaton Residual Current Circuit Breaker with Overload Protection, 10A Current Rating, 1-Pole, 30 mA Trip Sensitivity,
- RS-stocknr.:
- 183-3543
- Fabrikantnummer:
- 236962 PXK-C10/1N/003-A
- Fabrikant:
- Eaton
Subtotaal (1 eenheid)*
€ 168,06
(excl. BTW)
€ 203,35
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Op voorraad
- Plus verzending 105 stuk(s) vanaf 25 mei 2026
- Plus verzending 25 stuk(s) vanaf 25 mei 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 168,06 |
*prijsindicatie
- RS-stocknr.:
- 183-3543
- Fabrikantnummer:
- 236962 PXK-C10/1N/003-A
- Fabrikant:
- Eaton
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Eaton | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Current Rating | 10A | |
| Range | PXK | |
| Number of Poles | 1 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 240V ac | |
| Earth Leakage Protection Type | Type A | |
| Width | 2mm | |
| Depth | 69.5mm | |
| Breaking Capacity | 10kA | |
| Standards/Approvals | IEC/EN 61009 | |
| Tripping Mechanism | Non-Delayed | |
| Application | Commercial, Residential | |
| Alles selecteren | ||
|---|---|---|
Merk Eaton | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Current Rating 10A | ||
Range PXK | ||
Number of Poles 1 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 240V ac | ||
Earth Leakage Protection Type Type A | ||
Width 2mm | ||
Depth 69.5mm | ||
Breaking Capacity 10kA | ||
Standards/Approvals IEC/EN 61009 | ||
Tripping Mechanism Non-Delayed | ||
Application Commercial, Residential | ||
- Land van herkomst:
- AT
Eaton Residual Current Circuit Breaker With Overcurrent Protection, 1+N Poles - PXK-C Series - PXK-C10/1N/003-A
Looking for a combined solution that detects and protects against overload and short circuits? This Eaton RCBO (residual current circuit breaker with overcurrent protection) combines RCB (residual current device) and MCB (miniature circuit breaker) functionality to protect against earth leakage as well as overcurrent. It interrupts and disconnects power supplies when it detects a fault, protecting operators from electric shocks and equipment from damage. Attach this unit to your industrial circuits to enhance workplace safety.
• Operating temperature range of -25°C to +40°C for use with devices in demanding indoor and outdoor settings
• Trip sensitivity of 30mA prevents risk of electric shocks
• Type-C tripping characteristics ensure the device triggers disconnect within 5 seconds after fault detection
Why is an RCBO better than a circuit breaker?
Circuit breakers only disconnect the flow of current after a fault occurs. An RCBO, such as this one from Eaton, incorporates a circuit breaker and an overcurrent protector, which automatically interrupt the power supply when detecting even slight imbalances on a circuit. By doing this, it prevents damage to equipment and injury caused by electrocution.
Note
Eaton formerly known as Moeller
Gerelateerde Links
- Eaton, 1-Pole, 30 mA Trip Sensitivity
- Eaton, 1-Pole, 300 mA Trip Sensitivity
- Siemens LOGO! Series PLC CPU Starter Kit for Use with LOGO! V8.3, 115 V ac/dc, 230 V ac/dc Supply, Relay Output,
- Carling Technologies Illuminated DPDT, On-(On) Rocker Switch Panel Mount
- NVIDIA Jetson Orin Nano Super Developer Kit Development Kit
- RS PRO 4 Way Male 4 Pin Molex to 4 Way Female 4 Pin Molex Wire to Board Cable, 2m
- Siemens SIMATIC S7-1200 Series PLC CPU for Use with SIMATIC S7-1200 Series, Digital, Transistor Output, 14 (Digital, 2
- Pilz PNOZ X PNOZ X1 Emergency Stop Safety Relay, 24V ac/dc, Single Channel, 3 Safety Contacts