Eaton Residual Current Circuit Breaker with Overload Protection, 10A Current Rating, 1-Pole, 30 mA Trip Sensitivity,
- RS-stocknr.:
- 183-3538
- Fabrikantnummer:
- 236946 PXK-B10/1N/003-A
- Fabrikant:
- Eaton
Subtotaal (1 eenheid)*
€ 166,45
(excl. BTW)
€ 201,40
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Op voorraad
- Plus verzending 18 stuk(s) vanaf 27 april 2026
- Plus verzending 2 stuk(s) vanaf 27 april 2026
- Plus verzending 15 stuk(s) vanaf 01 mei 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 166,45 |
*prijsindicatie
- RS-stocknr.:
- 183-3538
- Fabrikantnummer:
- 236946 PXK-B10/1N/003-A
- Fabrikant:
- Eaton
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Eaton | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Current Rating | 10A | |
| Range | PXK | |
| Number of Poles | 1 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type B | |
| Rated AC Voltage | 240V ac | |
| Earth Leakage Protection Type | Type A | |
| Depth | 69.5mm | |
| Width | 2mm | |
| Standards/Approvals | IEC/EN 61009, IEC/EN 61439 | |
| Application | Residential, Commercial | |
| Breaking Capacity | 10kA | |
| Alles selecteren | ||
|---|---|---|
Merk Eaton | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Current Rating 10A | ||
Range PXK | ||
Number of Poles 1 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type B | ||
Rated AC Voltage 240V ac | ||
Earth Leakage Protection Type Type A | ||
Depth 69.5mm | ||
Width 2mm | ||
Standards/Approvals IEC/EN 61009, IEC/EN 61439 | ||
Application Residential, Commercial | ||
Breaking Capacity 10kA | ||
- Land van herkomst:
- AT
Eaton Residual Current Circuit Breaker With Overcurrent Protection, 1+N Poles - PXK-B Series - PXK-B10/1N/003-A
This Eaton RCBO (residual current breaker with overcurrent protection) automatically disconnects the electric current in the event of a malfunction. If leakage measuring 30mA occurs, the RCBO kicks into action and disables the entire system, preventing possible electrocution as well as damage to your system. You can install this circuit breaker as a protective measure against overcurrent and earth leakage in devices that function with voltages up to 240V. It's suitable for regulating current flow in power-control systems.
• Non-delayed tripping initiates instantaneous trip if a short circuit is detected, limiting damage
• IP20 (ingress protection 20) for resistance to dust, helping to prevent corrosion
• Partial protection against sudden electrical surges up to 250A
• High 10kA breaking capacity means greater durability in the event of malfunction
Does this Type B Eaton RCBO provide the same protection as an MCB?
Both devices have the same general functionality of protecting electrical systems from malfunctions. However, a MCB (miniature circuit breaker) doesn't provide complete protection against electrical shock. MCBs are generally used in small installations that require low current, whereas this RCBO is used in higher-voltage installations.
Note
Eaton formerly known as Moeller
Gerelateerde Links
- Eaton, 1-Pole, 30 mA Trip Sensitivity
- Eaton, 1-Pole, 300 mA Trip Sensitivity
- NVIDIA Jetson Orin Nano Super Developer Kit Development Kit
- Siemens SIMATIC S7-1200 Series PLC CPU for Use with SIMATIC S7-1200 Series, Digital, Transistor Output, 14 (Digital, 2
- Pilz PNOZ X PNOZ X1 Emergency Stop Safety Relay, 24V ac/dc, Single Channel, 3 Safety Contacts
- Siemens LOGO! Series PLC CPU Starter Kit for Use with LOGO! V8.3, 115 V ac/dc, 230 V ac/dc Supply, Relay Output,
- RS PRO 4 Way Male 4 Pin Molex to 4 Way Female 4 Pin Molex Wire to Board Cable, 2m
- Festo Natural Round Plastic Tube x 4mm OD x 2.6mm ID x 1.4mm