Eaton RCBO, 16A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type B, PXK Range

Subtotaal (1 eenheid)*

€ 166,45

(excl. BTW)

€ 201,40

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • Plus verzending 69 stuk(s) vanaf 15 december 2025
  • Plus verzending 15 stuk(s) vanaf 15 december 2025
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 166,45

*prijsindicatie

RS-stocknr.:
183-3540
Artikelnummer Distrelec:
303-96-434
Fabrikantnummer:
236948 PXK-B16/1N/003-A
Fabrikant:
Eaton
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Eaton

Current Rating

16A

Number of Poles

1P+N

Trip Sensitivity

30mA

Tripping Characteristics

Type B

Range

PXK

Circuit Breaker Type

RCD

Rated AC Voltage

240V

Mounting Style

DIN Rail Mount

Earth Leakage Protection Type

A

Overall Length

80mm

Overall Dimensions

(L) 80 x (H) 75 x (W) 35mm

Application

Commercial, Residential

Breaking Capacity at Maximum Voltage Rating

10 kA

Overall Width

35mm

Overall Depth

80mm

Land van herkomst:
AT

Eaton RCD, 16 A, Type B - PXK-B Series - PXK-B16/1N/003-A


Protect yourself and your electrical equipment from short circuits, surges and current overload with this Eaton RCD (residual current device). When the breaker detects any current imbalances – which can indicate a serious shock hazard – it isolates the circuit and cuts off the electricity. This quick action prevents shocks to operators and damage to equipment. Attach a breaker to each circuit so that a fault in one won't stop the other circuits from functioning.

• Breaking capacity at maximum voltage rating of 10 kA for safety
• Current rating of 16 A and AC voltage of 240 V for versatile use
• Switchgear suitable for domestic and commercial application

How much current is needed to trip this circuit breaker?


A trip sensitivity of 30 mA and type B tripping mean it breaks at a current of 120 to 150 mA within 40 milliseconds. This rates as high sensitivity.

How does this circuit breaker detect current leakage?


This unit detects small stray voltages by measuring the current on the circuit's supply and return conductors. It also features Type-A earth leakage protection, meaning it breaks the circuit for sinusoidal and alternating residual currents along with pulsed, DC residual currents that reach dangerous levels, for greater safety.

Note

Eaton formerly known as Moeller

Gerelateerde Links