Schneider Electric Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 1-Pole, 30 mA Trip
- RS-stocknr.:
- 654-654
- Fabrikantnummer:
- A9D56616
- Fabrikant:
- Schneider Electric
Subtotaal (1 eenheid)*
€ 116,00
(excl. BTW)
€ 140,36
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Op voorraad
- 26 stuk(s) klaar voor verzending
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 116,00 |
*prijsindicatie
- RS-stocknr.:
- 654-654
- Fabrikantnummer:
- A9D56616
- Fabrikant:
- Schneider Electric
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Schneider Electric | |
| Current Rating | 16A | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Range | Acti9 | |
| Series | A9d | |
| Number of Poles | 1 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type B | |
| Terminal Type | Screw Clamp | |
| Depth | 72mm | |
| Width | 18mm | |
| Height | 110mm | |
| Breaking Capacity | 10000A | |
| Application | Distribution | |
| Standards/Approvals | IEC 61009-2-2, IEC 61009-1, BS EN 61009-1 | |
| Alles selecteren | ||
|---|---|---|
Merk Schneider Electric | ||
Current Rating 16A | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Range Acti9 | ||
Series A9d | ||
Number of Poles 1 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type B | ||
Terminal Type Screw Clamp | ||
Depth 72mm | ||
Width 18mm | ||
Height 110mm | ||
Breaking Capacity 10000A | ||
Application Distribution | ||
Standards/Approvals IEC 61009-2-2, IEC 61009-1, BS EN 61009-1 | ||
- Land van herkomst:
- ES
The Schneider Electric Residual current circuit breaker with overcurrent protection (RCD/MCB) Acti 9 iDPN N Vigi, 6kA (IEC/EN 61009-2-1). 1-pole+N, rated current 16A, characteristic B, earth fault sensitivity 30mA, earth fault protection class Type A, operating voltage (Ue) 230V AC, insulation voltage (Ui) 400V AC. Ensures comprehensive protection of final circuits against overcurrent's and fault currents. Switches and disconnects circuits. Snap action for low-wear switching of the contacts. Mechanically isolated red indicator in case of fault tripping of the miniature circuit breaker or tripping due to a fault current. Clear switch position indication via green marking on the device's switch knob.
Number of protected poles is 1
Neutral position is Left
[In] Rated current is 16 A
Gerelateerde Links
- Schneider Electric RCBO, 1-Pole, 30 mA Trip Sensitivity
- Schneider Electric RCBO, 3-Pole, 30 mA Trip Sensitivity
- Schneider Electric RCBO, 1-Pole, 100 mA Trip Sensitivity
- Schneider Electric RCBO, 16A Current Rating, 4-Pole, 30 mA Trip Sensitivity, Type B, Acti9 Range, A9d Range
- Schneider Electric RCBO, 32A Current Rating, 2-Pole, 30 mA Trip Sensitivity, Type C, Acti9 Range, iC60 Range
- Schneider Electric RCBO, 20A Current Rating, 2-Pole, 30 mA Trip Sensitivity, Type C, Acti9 Range, iC60 Range
- Hager RCBO, 30 mA Trip Sensitivity, Type C
- Schneider Electric, 30 mA Trip Sensitivity