Schneider Electric RCBO, 16A Current Rating, 4-Pole, 30 mA Trip Sensitivity, Type B, Acti9 Range, A9d Range
- RS-stocknr.:
- 654-647
- Fabrikantnummer:
- A9D67416
- Fabrikant:
- Schneider Electric
Subtotaal (1 eenheid)*
€ 337,00
(excl. BTW)
€ 407,77
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Op voorraad
- Plus verzending 8 stuk(s) vanaf 25 mei 2026
- Plus verzending 3 stuk(s) vanaf 03 juni 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 337,00 |
*prijsindicatie
- RS-stocknr.:
- 654-647
- Fabrikantnummer:
- A9D67416
- Fabrikant:
- Schneider Electric
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Schneider Electric | |
| Product Type | RCBO | |
| Current Rating | 16A | |
| Range | Acti9 | |
| Number of Poles | 4 | |
| Series | A9d | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type B | |
| Terminal Type | Screw Clamp | |
| Depth | 72mm | |
| Height | 110mm | |
| Width | 18mm | |
| Standards/Approvals | BS EN 61009-1, IEC 61009-2-2, IEC 61009-1 | |
| Breaking Capacity | 10000A | |
| Application | Distribution | |
| Alles selecteren | ||
|---|---|---|
Merk Schneider Electric | ||
Product Type RCBO | ||
Current Rating 16A | ||
Range Acti9 | ||
Number of Poles 4 | ||
Series A9d | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type B | ||
Terminal Type Screw Clamp | ||
Depth 72mm | ||
Height 110mm | ||
Width 18mm | ||
Standards/Approvals BS EN 61009-1, IEC 61009-2-2, IEC 61009-1 | ||
Breaking Capacity 10000A | ||
Application Distribution | ||
- Land van herkomst:
- PT
The Schneider Electric Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 4P RCBO with 4 protected poles, rated current is 16A, and operating voltage is 380VAC to 415VAC. The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. Breaking capacity at 280VAC to 415VAC is 6000A according to EN/IEC 61009-2-1 and 6kA according to EN/IEC 60947-2. Its unique Visit rip indicator reduces intervention time by showing the faulty circuit. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with EN/IEC 60947-2 and EN/IEC 61009-2-1 standards.
Number of protected poles is 4
[In] rated current is 16 A
Network type is AC
Gerelateerde Links
- Schneider Electric RCBO, 32A Current Rating, 2-Pole, 30 mA Trip Sensitivity, Type C, Acti9 Range, iC60 Range
- Schneider Electric RCBO, 20A Current Rating, 2-Pole, 30 mA Trip Sensitivity, Type C, Acti9 Range, iC60 Range
- Schneider Electric Residential RCBO, 4A Current Rating, 1-Pole, 30 mA Trip Sensitivity, B Curve, Acti9 Range, Acti9 iDPN
- Hager RCBO, 16A Current Rating, 4-Pole, 30 mA Trip Sensitivity, Type A, Hager Range, ADX Range
- ABB RCBO, 16A Current Rating, 2-Pole, 30 mA Trip Sensitivity, Type A, DS301C Range, 2CSR255163R Range
- Schneider Electric RCBO, 32A Current Rating, 2P Poles, 30mA Trip Sensitivity, Resi9 Range
- Hager RCBO, 10A Current Rating, 4-Pole, 30 mA Trip Sensitivity, Type A, Hager Range, ADX Range
- Hager RCBO, 25A Current Rating, 4-Pole, 30 mA Trip Sensitivity, Type A, Hager Range, ADX Range
