Schneider Electric RCBO, 16A Current Rating, 4P Poles, 30mA Trip Sensitivity, Type B, Acti9 Range
- RS-stocknr.:
- 654-647
- Fabrikantnummer:
- A9D67416
- Fabrikant:
- Schneider Electric
Subtotaal (1 eenheid)*
€ 337,00
(excl. BTW)
€ 407,77
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Tijdelijk niet op voorraad
- Verzending 1 stuk(s) vanaf 18 december 2025
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 337,00 |
*prijsindicatie
- RS-stocknr.:
- 654-647
- Fabrikantnummer:
- A9D67416
- Fabrikant:
- Schneider Electric
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Schneider Electric | |
| Current Rating | 16A | |
| Number of Poles | 4 | |
| Range | Acti9 | |
| Series | A9D | |
| Circuit Breaker Type | RCBO | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type B | |
| Alles selecteren | ||
|---|---|---|
Merk Schneider Electric | ||
Current Rating 16A | ||
Number of Poles 4 | ||
Range Acti9 | ||
Series A9D | ||
Circuit Breaker Type RCBO | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type B | ||
- Land van herkomst:
- PT
The Schneider Electric Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 4P RCBO with 4 protected poles, rated current is 16A, and operating voltage is 380VAC to 415VAC. The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. Breaking capacity at 280VAC to 415VAC is 6000A according to EN/IEC 61009-2-1 and 6kA according to EN/IEC 60947-2. Its unique Visit rip indicator reduces intervention time by showing the faulty circuit. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with EN/IEC 60947-2 and EN/IEC 61009-2-1 standards.
Number of protected poles is 4
[In] rated current is 16 A
Network type is AC
[In] rated current is 16 A
Network type is AC
Gerelateerde Links
- Schneider Electric RCBO, 20A Current Rating, 1P Poles, 30mA Trip Sensitivity, Acti9 Range
- Schneider Electric RCBO, 40A Current Rating, 1P Poles, 30mA Trip Sensitivity, Acti9 Range
- Schneider Electric RCBO, 6A Current Rating, 1P Poles, 30mA Trip Sensitivity, Acti9 Range
- Schneider Electric RCBO, 10A Current Rating, 1P Poles, 30mA Trip Sensitivity, Acti9 Range
- Schneider Electric RCBO, 25A Current Rating, 1P Poles, 30mA Trip Sensitivity, Acti9 Range
- Schneider Electric RCBO, 16A Current Rating, 1P Poles, 30mA Trip Sensitivity, Acti9 Range