Fluke 9062 Phase Rotation Tester 2 Hz, 400 Hz Max, 400V ac Max
- RS-stocknr.:
- 513-1834
- Artikelnummer Distrelec:
- 176-45-534
- Fabrikantnummer:
- FLUKE 9062
- Fabrikant:
- Fluke
Subtotaal (1 eenheid)*
€ 304,00
(excl. BTW)
€ 367,84
(incl. BTW)
Informatie over voorraden is momenteel niet toegankelijk - Controleer het later nog eens opnieuw
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 304,00 |
*prijsindicatie
- RS-stocknr.:
- 513-1834
- Artikelnummer Distrelec:
- 176-45-534
- Fabrikantnummer:
- FLUKE 9062
- Fabrikant:
- Fluke
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke | |
| Product Type | Phase Rotation Tester | |
| Connection Type | Test Probe | |
| Overvoltage Category | CAT III 300V | |
| Display Type | LED | |
| Non-Contact | No | |
| Current Consumption | 20mA | |
| Power Source | Battery | |
| Minimum Operating Temperature | 0°C | |
| Weight | 150g | |
| Maximum Operating Temperature | 40°C | |
| Height | 124mm | |
| Standards/Approvals | No | |
| Length | 61mm | |
| Maximum Frequency | 400Hz | |
| Width | 27mm | |
| Maximum Voltage | 400V ac | |
| Model Number | 9062 | |
| Minimum Frequency | 2Hz | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke | ||
Product Type Phase Rotation Tester | ||
Connection Type Test Probe | ||
Overvoltage Category CAT III 300V | ||
Display Type LED | ||
Non-Contact No | ||
Current Consumption 20mA | ||
Power Source Battery | ||
Minimum Operating Temperature 0°C | ||
Weight 150g | ||
Maximum Operating Temperature 40°C | ||
Height 124mm | ||
Standards/Approvals No | ||
Length 61mm | ||
Maximum Frequency 400Hz | ||
Width 27mm | ||
Maximum Voltage 400V ac | ||
Model Number 9062 | ||
Minimum Frequency 2Hz | ||
Vrijgesteld
Fluke Phase Rotation Tester, 400V Maximum Voltage, 2Hz Minimum Frequency - FLUKE 9062
This phase rotation tester provides a Rapid indication of three-phase sequence and motor rotation direction in commercial and industrial settings. It determines phase order with either supplied test leads or by non-contact sensing of running motors, enabling electricians and engineers to confirm rotary field direction without requiring shaft visibility. The instrument operates across common supply frequencies and voltages used in motor and installation testing and is powered by a single battery for field portability.
Features & Benefits
• Phase indication up to 400VAC for broad system compatibility
• Frequency response from 2–400Hz to cover slow to fast machines
• LED display for immediate, easily readable phase sequence information
• Contactless motor rotation detection to assess running equipment safely
• Low current draw at 20mA for extended battery operation
• CAT III 300V safety rating suitable for fixed installation testing
• Frequency response from 2–400Hz to cover slow to fast machines
• LED display for immediate, easily readable phase sequence information
• Contactless motor rotation detection to assess running equipment safely
• Low current draw at 20mA for extended battery operation
• CAT III 300V safety rating suitable for fixed installation testing
**Applications**
• Suitable for verifying phase order on motor control panels
• Ideal for assessing rotation of synchronous and asynchronous motors while running
• Used with distribution boards during commissioning and fault-finding
• Can be used for maintenance checks where shafts are inaccessible
• Used for on-site confirmation prior to motor coupling and installation
• Ideal for assessing rotation of synchronous and asynchronous motors while running
• Used with distribution boards during commissioning and fault-finding
• Can be used for maintenance checks where shafts are inaccessible
• Used for on-site confirmation prior to motor coupling and installation
How is the device powered and what are the supply requirements for field use?
It runs from a single 9V battery and draws approximately 20mA during measurement, providing portable operation for site tasks.
Can the tester operate at low supply frequencies encountered in specialised equipment?
Yes, it accurately indicates phase sequence down to 2Hz, accommodating variable-speed drives and slow-turning machinery.
What environmental limits should be observed during operation?
The instrument is rated for continuous use between 0°C and 40°C and for altitudes up to 2000m with humidity up to 80% non‑condensing.
Are probe accessories provided for different connection types?
The package includes test leads, probes and crocodile clips enabling both temporary contact testing and clamped connections in industrial sockets.
How does the unit indicate phase sequence visually?
It uses an LED display to show rotary field direction and phase order for quick verification on site.
Gerelateerde Links
- Fluke 9062 Phase Rotation Tester 2 Hz, 400 Hz Max, 400V ac Max
- Fluke 9040 Phase Rotation Tester 15 Hz, 400 Hz Max, 700V Max
- RS PRO RS9020 Phase Rotation Tester 2 Hz, 400 Hz Max, 400V ac Max Non-Contact
- Penta Phase Rotation Tester 50 Hz, 60 Hz Max, 400V Max
- Catu MS-153 Phase Rotation Tester 50 Hz, 60 Hz Max, 400V Max
- RS PRO Phase Rotation Tester 45 Hz, 400 Hz Max, 600V ac Max
- Extech 480400 Phase Rotation Tester 15 Hz, 400 Hz Max, 600V ac Max
- Megger MTR105 Phase Rotation Tester 15 Hz, 400 Hz Max, 75V Max