Pico Technology TA057 Oscilloscope Probe, Active, Differential Type, 25MHz, 1:20, 1:200, BNC Connector

Subtotaal (1 eenheid)*

€ 413,09

(excl. BTW)

€ 499,84

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 13 stuk(s) klaar voor verzending
  • 12 stuk(s) klaar voor verzending vanaf een andere locatie
  • Plus verzending 19 stuk(s) vanaf 19 december 2025
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 413,09

*prijsindicatie

RS-stocknr.:
898-6766
Fabrikantnummer:
TA057
Fabrikant:
Pico Technology
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Pico Technology

Probe Type

Active, Differential

Attenuation

1:20, 1:200

Bandwidth

25MHz

Maximum Common Mode Input Voltage

1kV

Connector Type

BNC

Model Number p

TA057

Number of Probes

2

Safety Category

1000 V, CAT III ±1400V

Land van herkomst:
TW

Pico Technology Oscilloscope Probe


The Pico Technology TA057 oscilloscope probe is an active differential probe, suitable for high common-mode voltage measurement applications up to ±1400V. It can be used with a signal speed of up to 25MHz. This differential probe extends the functionality of standard single-ended input oscilloscopes to allow a safe and accurate method of making high voltage differential measurements.

Features and Benefits


Bandwidth is DC to 25MHz (–3dB)
Attenuation ratio is 20:1/200:1
Accuracy is ±2%
Input impedance is 4Mohm 5.5pF each side to ground
Differential range is ±140V (DC + peak AC) or 140VRMS at 20:1
Maximum differential is ±1400V (DC + peak AC) or 1000V RMS at 200:1
Common mode range is ±700V (DC + peak AC) or 500VRMS (10:1 & 100:1)
Absolute maximum voltage is ±1400V (DC + peak AC) or 1000VRMS CAT III
at 20:1 and 200:1
Swing is ±7V into 50Kohm load
Offset (typical) is <±5mV
Noise (typical) is 0.7mVRMS
Source impedance is 1ohm at 1kHz and 8ohm at 1MHz
CMRR (typical) is 80dB at 50Hz and 60dB at 20kHz
Ambient operating temperature ranges between -10°C and +40°C
Power requirement 4xAA cells or 6VDC/60mA mains adaptor or regulated 9VDC/40mA mains adaptor

Applications


Safe measurement in power circuit
Acquisition of low speed balanced differential signals found in serial communications buses
Transients in switching power supplies, inverters and motor drives, electronic ballasts and CRT displays
Signals in the milliV range from sensors and other instrumentation

Certifications


IEC-1010.1
IEC-1010.2-031 CAT III
Pollution Degree 2

Gerelateerde Links