Fluke 287 Handheld Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 1000V ac Max - RS Calibrated
- RS-stocknr.:
- 218-400
- Fabrikantnummer:
- 3947781
- Fabrikant:
- Fluke
Subtotaal (1 eenheid)*
€ 1.065,83
(excl. BTW)
€ 1.289,65
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
- 9 resterend, klaar voor verzending
- Plus verzending 27 stuk(s) vanaf 25 december 2025
- Plus verzending 17 stuk(s) vanaf 22 januari 2026
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 1.065,83 |
*prijsindicatie
- RS-stocknr.:
- 218-400
- Fabrikantnummer:
- 3947781
- Fabrikant:
- Fluke
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke | |
| Multimeter Type | Handheld | |
| Model Number p | 287 | |
| Display Type | Digital | |
| Calibrated | RSCAL | |
| Functions Measured | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | |
| Absolute Maximum AC Current Measurement | 10A ac | |
| Absolute Maximum AC Voltage Measurement | 1000V ac | |
| Absolute Maximum DC Voltage Measurement | 1000V dc | |
| Absolute Maximum Resistance Measurement | 500MΩ | |
| Absolute Maximum DC Current Measurement | 10A dc | |
| Absolute Maximum Temperature Measurement | +1350°C | |
| True RMS | Yes | |
| Absolute Maximum Capacitance Measurement | 100mF | |
| Maximum Frequency | 100kHz | |
| DC Voltage Measurement Resolution | 1µV dc | |
| Safety Category Level | CAT III, CAT IV | |
| Best AC Voltage Accuracy | ±0.025 % | |
| Best Capacitance Measurement Accuracy | ±1 % | |
| Best AC Current Accuracy | ±0.15 % | |
| Width | 102mm | |
| Safety Category Voltage | 600 V, 1000V | |
| Battery Type | AA x 6 | |
| Best Resistance Measurement Accuracy | ±0.05 % | |
| Minimum Operating Temperature | -20°C | |
| Height | 222mm | |
| Weight | 870.9g | |
| Best DC Current Accuracy | ±0.15 % | |
| Best DC Voltage Accuracy | ±0.025 % | |
| Maximum Operating Temperature | +55°C | |
| Length | 60mm | |
| Dimensions | 60 x 102 x 222mm | |
| Best Temperature Measurement Accuracy | ±1 % | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke | ||
Multimeter Type Handheld | ||
Model Number p 287 | ||
Display Type Digital | ||
Calibrated RSCAL | ||
Functions Measured AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | ||
Absolute Maximum AC Current Measurement 10A ac | ||
Absolute Maximum AC Voltage Measurement 1000V ac | ||
Absolute Maximum DC Voltage Measurement 1000V dc | ||
Absolute Maximum Resistance Measurement 500MΩ | ||
Absolute Maximum DC Current Measurement 10A dc | ||
Absolute Maximum Temperature Measurement +1350°C | ||
True RMS Yes | ||
Absolute Maximum Capacitance Measurement 100mF | ||
Maximum Frequency 100kHz | ||
DC Voltage Measurement Resolution 1µV dc | ||
Safety Category Level CAT III, CAT IV | ||
Best AC Voltage Accuracy ±0.025 % | ||
Best Capacitance Measurement Accuracy ±1 % | ||
Best AC Current Accuracy ±0.15 % | ||
Width 102mm | ||
Safety Category Voltage 600 V, 1000V | ||
Battery Type AA x 6 | ||
Best Resistance Measurement Accuracy ±0.05 % | ||
Minimum Operating Temperature -20°C | ||
Height 222mm | ||
Weight 870.9g | ||
Best DC Current Accuracy ±0.15 % | ||
Best DC Voltage Accuracy ±0.025 % | ||
Maximum Operating Temperature +55°C | ||
Length 60mm | ||
Dimensions 60 x 102 x 222mm | ||
Best Temperature Measurement Accuracy ±1 % | ||
Vrijgesteld
- Land van herkomst:
- US
Fluke 287 Digital Multimeter
The Fluke 287 packs more accuracy and convenience into a hand held multimeter than ever before. Various ranges can be recorded from minutes to hours and even including days. The Fluke 287 comes with a real-time clock, min/max add on and graphing through TrendCapture. Data can be exported to your phone through the infrared optical.
The Fluke 287 is fairly complex but it has a user-friendly interface, help screens and is multi-lingual. Graphs can be zoomed in for higher resolutions, and after exporting through Fluke Connect you can share your data via ShareLive video. Data can also be saved and analysed into documents via FlukeView. However you need to buy the adapter to transfer the data and also the software.
Features and Benefits
True-rms ac bandwidth 100 kHz; dBV/dBm; dc mV resolution 1 μV; MΩ range up to 500 mΩ
Conductance 50.00 Ns
Min/Max/Avg/duty cycle/pulse width
Isolated optical digital multimeter interface with USB PC connection
Over 200 hours logging capacity with new power-saving function
Full range True-RMS multimeter, including: current to 20A for 30s, capacitance for 1 nF, temperature (with separate probe)
Data log up to 15000 events over time
Trend Capture with zoom (up to 14 times) to determine whether anomalies may have occurred
Large 50000 Count, 1/4 VGA display with backlight
DC accuracy: 0.025%
100 kHz AC bandwidth
Real-time clock for time stamping
Smoothing mode to steady noisy signals
What is the difference between the Fluke 287 and 289 Digital Multimeter?
Advantages of using the Fluke 287
Large display with readouts
Advanced min/max and peak max mode
Good capacitance range
Fast and accurate response time
Excellent auto range function with high resolution
High-quality input protection (to 8 kV)
Quality probes with tip guards
Applications include:
Industrial
Maintenance and Repair
Gerelateerde Links
- Fluke 287 Handheld Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 1000V ac Max - UKAS Calibrated
- Fluke 287 Handheld Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 1000V ac Max
- Fluke 177 Handheld Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 1000V ac Max
- Fluke 233 Handheld Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 1000V ac Max
- Fluke 115 Handheld Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 600V ac Max
- Fluke 179 Handheld Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 1000V ac Max
- Fluke 83 Handheld Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 1000V ac Max
- Fluke 175 Handheld Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 1000V ac Max
