Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke | |
| Product Type | Electrical Tester | |
| Model Number | T6-600 | |
| Maximum Voltage Measurement | 600V ac | |
| Test Type | MOSFET, Resistance, SSR Isolated Flyback Converter | |
| Battery Life | 200h | |
| Weight | 350g | |
| Standards/Approvals | No | |
| Length | 61.1mm | |
| Height | 259.3mm | |
| Width | 43.8mm | |
| Minimum Operating Temperature | -10°C | |
| Maximum Continuity Resistance | 2000Ω | |
| Safety Category Voltage | 600V | |
| Safety Category Level | CAT III | |
| Display Type | Digital | |
| Battery Type | AA LR06 | |
| Maximum Operating Temperature | 50°C | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke | ||
Product Type Electrical Tester | ||
Model Number T6-600 | ||
Maximum Voltage Measurement 600V ac | ||
Test Type MOSFET, Resistance, SSR Isolated Flyback Converter | ||
Battery Life 200h | ||
Weight 350g | ||
Standards/Approvals No | ||
Length 61.1mm | ||
Height 259.3mm | ||
Width 43.8mm | ||
Minimum Operating Temperature -10°C | ||
Maximum Continuity Resistance 2000Ω | ||
Safety Category Voltage 600V | ||
Safety Category Level CAT III | ||
Display Type Digital | ||
Battery Type AA LR06 | ||
Maximum Operating Temperature 50°C | ||
- Land van herkomst:
- CN
Fluke Electrical Tester, 600V Maximum Voltage Measurement, CAT III Safety Category Level - T6-600
This electrical tester provides non-contact measurement of AC voltage, current and frequency for industrial and field environments. It uses an open-fork sensing method to assess live conductors without requiring probe contact, and also accepts conventional test leads for direct voltage and resistance checks. The instrument is intended for electricians and engineers working on power distribution, machinery and control systems where rapid, safer diagnostics are needed.
Features & Benefits
• FieldSense non-contact voltage measurement up to 600V reduces exposure to live terminals
• Simultaneous display of voltage and current speeds up troubleshooting tasks
• Current range to 200 A accommodates large conductors up to AWG 4/0
• Resistance measurement to 2000 Ω assists continuity and component checks
• Operates on 2 x AA batteries for long runtime during field use
• Frequency detection over 45–66 Hz verifies supply and generator conditions
• Simultaneous display of voltage and current speeds up troubleshooting tasks
• Current range to 200 A accommodates large conductors up to AWG 4/0
• Resistance measurement to 2000 Ω assists continuity and component checks
• Operates on 2 x AA batteries for long runtime during field use
• Frequency detection over 45–66 Hz verifies supply and generator conditions
**Applications**
• Suitable for diagnosing power supplies in industrial automation systems
• Ideal for checking line current and voltage on motors and drives
• Used for fault-finding in electrical distribution panels and switchgear
• Can be used for resistor and continuity checks on control circuits
• Used with SSR and MOSFET assemblies during maintenance and testing
• Ideal for checking line current and voltage on motors and drives
• Used for fault-finding in electrical distribution panels and switchgear
• Can be used for resistor and continuity checks on control circuits
• Used with SSR and MOSFET assemblies during maintenance and testing
What conditions affect non-contact measurement accuracy?
Non-contact readings require a capacitive path to earth
accuracy is reduced without an external earth connection and when the user is insulated from earth, such as when wearing insulating gloves or on an insulated ladder.
How does the tester handle frequency measurement?
Frequency is measured within a limited band centred on mains frequencies and is specified from 45 Hz to 66 Hz with a 1 Hz resolution and an accuracy of ±(1% + 2 counts).
What environmental limits apply to operation and storage?
It operates between −10 °C and +50 °C and stores between −30 °C and +60 °C
altitude limits are 2000m for operation and 10 000m for storage.
What protective rating and safety classification does it meet?
The instrument is rated for measurement category CAT III at 600V for use in typical installation work.
What accessories and test lead options are available?
It ships with attached test leads and removable probe caps and supports optional accessories such as magnetic hangers, proving units and various probe and clip sets for expanded use.
Note
Please ensure voltage is measured without test leads
Supplied with
The Fluke T6-600 comes with attached test leads with removable 4 mm probe caps and user documentation
Optional accessories:
FLUKE T6 Holster with belt loop for T6-600 / T6-1000 1462608
Optional accessories:
FLUKE T6 Holster with belt loop for T6-600 / T6-1000 1462608
Gerelateerde Links
- Fluke T6-1000 Electrical Tester
- Fluke T6-600 Multifunction Tester
- Fluke T6-1000, LCD Voltage Tester, 1000V, Battery Powered CAT IV, CAT III, T6-1000
- Fluke T5 Multifunction Tester
- Fluke T5 Multifunction Tester RSCAL
- Fluke 1672 Electrical Installation Tester 10000V With USB Type C
- Fluke 1673 Electrical Installation Tester 1000V Earth Resistance Measurement With USB
- Fluke 1674 Electrical Installation Tester 1000V Earth Resistance Measurement With USB