Fluke calibration, RTD Probe Handheld 1551A Digital Thermometer, 1 Input(s), 160 °C Max, ±0.05°C Accuracy, RSCAL
- RS-stocknr.:
- 735-6565
- Fabrikantnummer:
- 1551A-12-DL
- Fabrikant:
- Fluke calibration
Subtotaal (1 eenheid)*
€ 1.592,50
(excl. BTW)
€ 1.926,92
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Beperkte voorraad
- 1 resterend, klaar voor verzending
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 1.592,50 |
*prijsindicatie
- RS-stocknr.:
- 735-6565
- Fabrikantnummer:
- 1551A-12-DL
- Fabrikant:
- Fluke calibration
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke calibration | |
| Maximum Temperature Measurement | 160°C | |
| Product Type | Digital Thermometer | |
| Model Number | 1551A | |
| Thermometer Type | Handheld | |
| Probe Type | RTD | |
| Accuracy | ±0.05°C | |
| Number of Temperature Inputs | 1 | |
| Data Storage | Yes | |
| Power Source | Battery | |
| Resolutions Supported | 0.001°C | |
| Battery Life | 300h | |
| Width | 57mm | |
| Standards/Approvals | No | |
| Hazardous Area Certification | ATEX | |
| Length | 114mm | |
| Weight | 196g | |
| Height | 25mm | |
| Temperature Scale | F, °C, Fahrenheit | |
| Application | Industrial | |
| Minimum/Maximum Recordings | Yes | |
| Calibrated | RSCAL | |
| Battery Type | AAA | |
| Intrinsically Safe | Yes | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke calibration | ||
Maximum Temperature Measurement 160°C | ||
Product Type Digital Thermometer | ||
Model Number 1551A | ||
Thermometer Type Handheld | ||
Probe Type RTD | ||
Accuracy ±0.05°C | ||
Number of Temperature Inputs 1 | ||
Data Storage Yes | ||
Power Source Battery | ||
Resolutions Supported 0.001°C | ||
Battery Life 300h | ||
Width 57mm | ||
Standards/Approvals No | ||
Hazardous Area Certification ATEX | ||
Length 114mm | ||
Weight 196g | ||
Height 25mm | ||
Temperature Scale F, °C, Fahrenheit | ||
Application Industrial | ||
Minimum/Maximum Recordings Yes | ||
Calibrated RSCAL | ||
Battery Type AAA | ||
Intrinsically Safe Yes | ||
Niet conform
- Land van herkomst:
- US
Fluke Digital Thermometer, 160°C Maximum Temperature, ±0.05°C Accuracy - 1551A-12-DL
This digital thermometer is a handheld instrument designed for industrial temperature measurement and process verification. It operates from AAA batteries and is suitable for hazardous environments due to ATEX intrinsic safety certification. The device accepts a single RTD probe input and provides high-resolution readings for single-point checks, data logging and field calibration tasks up to a maximum of 160°C.
Features and Benefits:
• ±0.05°C accuracy provides precise temperature readings
• 0.001 resolution enables fine incremental measurement
• 300 h battery life supports extended field use
• Intrinsically safe ATEX design permits use in hazardous areas
• Data storage records measurements for later analysis
• RTD probe input ensures compatibility with industrial sensors
• 0.001 resolution enables fine incremental measurement
• 300 h battery life supports extended field use
• Intrinsically safe ATEX design permits use in hazardous areas
• Data storage records measurements for later analysis
• RTD probe input ensures compatibility with industrial sensors
Applications
• Suitable for single-point process temperature verification
• Used for RTD sensor checks during transmitter calibration
• Ideal for portable field logging and trend checks
• Used with dry-wells or micro-baths for bench calibration
• Suitable for industrial switch and controller verification
• Used for RTD sensor checks during transmitter calibration
• Ideal for portable field logging and trend checks
• Used with dry-wells or micro-baths for bench calibration
• Suitable for industrial switch and controller verification
What probe type does it accept?
It accepts an RTD probe input configured for single-channel resistance-to-temperature measurement.
How does battery power affect portability?
AAA battery operation provides lightweight, field-service power and enables up to 300 h of continuous use between replacements.
Can it be used where explosive atmospheres exist?
Yes, it is intrinsically safe and ATEX certified for use in hazardous atmospheres.
What measurement range and limits apply?
The instrument measures temperatures up to 160°C and is intended for industrial process ranges within that limit.
How precise are logged readings for calibration records?
Logged data benefit from 0.001 resolution and the stated ±0.05°C accuracy, suitable for documented verification and comparison.
Note
Model number appended with a -9, -12, -20 indicates probe sheath length in inches. All probe diameters are 6.35 mm with the exception of the 1551A-9, which is 4.8 mm diameter
Supplied with
3 x AAA batteries and instruction manual on CD ROM
Gerelateerde Links
- Fluke calibration 1551A Handheld Digital Thermometer, RTD Probe, 1 Input(s), 160 °C Max, ±0.05°C Accuracy
- Fluke calibration 1551A Handheld Digital Thermometer, RTD Probe, 1 Input(s), 160 °C Max, ±0.05°C Accuracy, UKAS
- Fluke calibration 1551A Handheld Digital Thermometer, RTD Probe, 1 Input(s), 160 °C Max, ±0.05°C Accuracy, RSCAL
- Fluke calibration 1551A Handheld Digital Thermometer, RTD Probe, 1 Input(s), +160 °C Max, ±0.05°C Accuracy
- Fluke calibration 1551A Handheld Digital Thermometer, RTD Probe, 1 Input(s), +160 °C Max, ±0.05°C Accuracy, UKAS
- Fluke calibration 1551A Handheld Digital Thermometer, RTD Probe, 1 Input(s), +160 °C Max, ±0.05°C Accuracy, RSCAL
- Fluke calibration 1551A Recording Digital Thermometer, PT100 Probe, 1 Input(s), 160 °C Max, ±0.05°C Accuracy
- Fluke calibration 1551A Recording Digital Thermometer, PT100 Probe, 1 Input(s), 160 °C Max, ±0.05°C Accuracy, UKAS