Fluke calibration, RTD Probe Handheld 1551A Digital Thermometer, 1 Input(s), 160 °C Max, ±0.05°C Accuracy, UKAS
- RS-stocknr.:
- 735-6537
- Fabrikantnummer:
- 1551A-9-DL
- Fabrikant:
- Fluke calibration
Subtotaal (1 eenheid)*
€ 1.580,34
(excl. BTW)
€ 1.912,21
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
- Plus verzending 1 stuk(s) vanaf 17 november 2026
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 1.580,34 |
*prijsindicatie
- RS-stocknr.:
- 735-6537
- Fabrikantnummer:
- 1551A-9-DL
- Fabrikant:
- Fluke calibration
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke calibration | |
| Maximum Temperature Measurement | 160°C | |
| Product Type | Digital Thermometer | |
| Model Number | 1551A | |
| Thermometer Type | Handheld | |
| Probe Type | RTD | |
| Accuracy | ±0.05°C | |
| Number of Temperature Inputs | 1 | |
| Data Storage | Yes | |
| Power Source | Battery | |
| Resolutions Supported | 0.001°C | |
| Battery Life | 300h | |
| Height | 25mm | |
| Weight | 196g | |
| Width | 57mm | |
| Standards/Approvals | EN 61326:2006 | |
| Hazardous Area Certification | ATEX | |
| Length | 114mm | |
| Application | Industrial | |
| Temperature Scale | °C, Fahrenheit, F | |
| Minimum/Maximum Recordings | Yes | |
| Battery Type | 3 x AAA Alkaline | |
| Intrinsically Safe | Yes | |
| Calibrated | UKAS | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke calibration | ||
Maximum Temperature Measurement 160°C | ||
Product Type Digital Thermometer | ||
Model Number 1551A | ||
Thermometer Type Handheld | ||
Probe Type RTD | ||
Accuracy ±0.05°C | ||
Number of Temperature Inputs 1 | ||
Data Storage Yes | ||
Power Source Battery | ||
Resolutions Supported 0.001°C | ||
Battery Life 300h | ||
Height 25mm | ||
Weight 196g | ||
Width 57mm | ||
Standards/Approvals EN 61326:2006 | ||
Hazardous Area Certification ATEX | ||
Length 114mm | ||
Application Industrial | ||
Temperature Scale °C, Fahrenheit, F | ||
Minimum/Maximum Recordings Yes | ||
Battery Type 3 x AAA Alkaline | ||
Intrinsically Safe Yes | ||
Calibrated UKAS | ||
Niet conform
- Land van herkomst:
- US
Fluke Digital Thermometer, ±0.05°C Accuracy, 160°C Maximum Temperature Measurement - 1551A-9-DL
Features & Benefits
• Measures up to 160°C to cover common process ranges
• Intrinsically safe design allows use in classified hazardous areas
• Stores measurement data to assist traceable logging
• Wired RTD probe input enables robust sensor connectivity
**Applications**
• Ideal for temperature transmitter calibration in process control
• Used for custody transfer and PET calibration checks
• Can be used for on-site verification of industrial RTDs
• Used with loop and pressure calibrators during maintenance
What power source does it use and how long will it run between battery changes?
Which measurement scales and probe type are supported?
Is the instrument suitable for use in potentially explosive atmospheres?
How is measurement history handled for audits or verification?
Note
Supplied with
Gerelateerde Links
- Fluke calibration, RTD Probe Handheld 1551A Digital Thermometer, 1 Input(s), 160 °C Max, ±0.05°C Accuracy
- Fluke calibration, RTD Probe Handheld 1551A Digital Thermometer, 1 Input(s), 160 °C Max, ±0.05°C Accuracy, RSCAL
- Fluke calibration, RTD Probe Handheld 1551A Digital Thermometer, 1 Input(s), 160 °C Max, ±0.05°C Accuracy, UKAS
- Fluke calibration, RTD Probe Handheld 1551A Digital Thermometer, 1 Input(s), +160 °C Max, ±0.05°C Accuracy
- Fluke calibration, RTD Probe Handheld 1551A Digital Thermometer, 1 Input(s), +160 °C Max, ±0.05°C Accuracy, UKAS
- Fluke calibration, RTD Probe Handheld 1551A Digital Thermometer, 1 Input(s), +160 °C Max, ±0.05°C Accuracy, RSCAL
- Fluke calibration, PT100 Probe Recording 1551A Digital Thermometer, 1 Input(s), 160 °C Max, ±0.05°C Accuracy
- Fluke calibration, PT100 Probe Recording 1551A Digital Thermometer, 1 Input(s), 160 °C Max, ±0.05°C Accuracy, UKAS