Alpha Wire 0.75mm² Polyvinyl Chloride Sheath

Subtotaal (1 rol van 100 meter)*

€ 446,88

(excl. BTW)

€ 540,72

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • Plus verzending 2 stuk(s) vanaf 30 maart 2026
  • Plus verzending 3 stuk(s) vanaf 23 juni 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len)
Per rol
Per meter*
1 +€ 446,88€ 4,469

*prijsindicatie

RS-stocknr.:
181-1806
Fabrikantnummer:
470127YY GE033
Fabrikant:
Alpha Wire
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Alpha Wire

Jacket Material

Polyvinyl Chloride

Belden Pro-Met Series Control Cable, 100m Length, 12 Cores - 470127YY GE033


This 12-core control cable is designed for industrial signal and control circuits in automated and electrical systems, offering multi-core flexibility within a single grey PVC-sheathed assembly. It is intended for fixed and limited-motion installations where a compact, multi-conductor cable provides reliable interconnection under typical industrial temperature ranges.

Features & Benefits


• 12 bare copper conductors, 30 strands each, for enhanced flexibility
• PVC insulation and jacket permitting oil and UV resistance
• Rated 300/500V for low-voltage control circuits
• Operating range -40 to 80°C to suit cold and warm environments
• Unscreened construction reducing cost and simplifying termination
• IEC 60332-1 flame behaviour for improved fire safety performance

Applications


• Suitable for factory automation control wiring in machinery panels
• Ideal for motor starter and relay interconnections in control cabinets
• Used with PLC I/O and distributed control systems for signal routing
• Can be used for building services and HVAC control circuits

What conductor construction ensures flexibility for routing in trays?


Each conductor comprises 30 fine strands of bare copper, which increases cable pliability for routing through trays and conduits.

How is core identification handled for installation?


Eleven cores are individually coloured black with sequential identification and one core is yellow/green for earth, enabling straightforward core identification during termination.

What mechanical handling guidance applies to bending?


A minimum static bend radius of four times the cable diameter is recommended to prevent undue mechanical stress during installation.

How is the sheath marked for traceability and certification?


The outer jacket is printed with manufacturer details, voltage rating and relevant conformity markings to assist identification on site.

What packaging options are available for procurement?


Continuous lengths are supplied on spools or flanges in multiple put-ups including 100m to suit different installation needs.