ABB GJL131 Contactor, 48V Coil, 3-Pole, 20 A, 5.5 kW 48V, 4 NO, 690V dc
- RS-stocknr.:
- 253-4835
- Fabrikantnummer:
- GJL1313001R1106
- Fabrikant:
- ABB
Afbeelding representeert productcategorie
Subtotaal (1 verpakking van 10 eenheden)*
€ 361,32
(excl. BTW)
€ 437,20
(incl. BTW)
Informatie over voorraden is momenteel niet toegankelijk - Controleer het later nog eens opnieuw
Aantal stuks | Per stuk | Per verpakking* |
|---|---|---|
| 10 + | € 36,132 | € 361,32 |
*prijsindicatie
- RS-stocknr.:
- 253-4835
- Fabrikantnummer:
- GJL1313001R1106
- Fabrikant:
- ABB
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Coil Voltage | 48V | |
| Product Type | Contactor | |
| Number of Poles | 3 | |
| Contact Voltage | 690V dc | |
| Contact Current | 20A | |
| Power Rating | 5.5kW | |
| Series | GJL131 | |
| Function | Control Unit | |
| Mount Type | DIN Rail, Wall | |
| Normal State Configuration | 4 NO | |
| Number of Auxiliary Contacts | 1 | |
| Auxiliary Contact Configuration | 1 NO/0 NC | |
| Terminal Type | Screw | |
| Contactor Application | Control Unit | |
| Operational Current Ie | 20A | |
| Control Circuit Voltage Uc | 48V | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | 55°C | |
| Width | 52.5mm | |
| Standards/Approvals | IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | |
| Depth | 46.7mm | |
| Length | 46.7mm | |
| Pole and Throw Configuration | 3P | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Coil Voltage 48V | ||
Product Type Contactor | ||
Number of Poles 3 | ||
Contact Voltage 690V dc | ||
Contact Current 20A | ||
Power Rating 5.5kW | ||
Series GJL131 | ||
Function Control Unit | ||
Mount Type DIN Rail, Wall | ||
Normal State Configuration 4 NO | ||
Number of Auxiliary Contacts 1 | ||
Auxiliary Contact Configuration 1 NO/0 NC | ||
Terminal Type Screw | ||
Contactor Application Control Unit | ||
Operational Current Ie 20A | ||
Control Circuit Voltage Uc 48V | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature 55°C | ||
Width 52.5mm | ||
Standards/Approvals IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | ||
Depth 46.7mm | ||
Length 46.7mm | ||
Pole and Throw Configuration 3P | ||
- Land van herkomst:
- DE
ABB GJL131 Series Contactor, 20A Current Rating, 48V Control Circuit Voltage - GJL1313001R1106
This contactor is an electromechanical switching device designed to control three-phase loads across residential, commercial and industrial settings. It operates with a 48V control circuit and provides switching for motors and other equipment up to 5.5 kW, integrating a single auxiliary contact to support control logic and signalling functions.
Features and Benefits:
• 3P configuration delivering 20 A operational current for motor control
• Rated for switching up to 690V DC for high-voltage applications
• DIN rail or wall-mount options for flexible installation
• Screw Terminal connections for secure conductor termination
• Operates between -25 °C and 55 °C for varied ambient conditions
• Conforms to IEC/EN and UL standards for recognised interoperability
• Rated for switching up to 690V DC for high-voltage applications
• DIN rail or wall-mount options for flexible installation
• Screw Terminal connections for secure conductor termination
• Operates between -25 °C and 55 °C for varied ambient conditions
• Conforms to IEC/EN and UL standards for recognised interoperability
Applications
• Suitable for motor starters in light industrial plants
• Ideal for HVAC control panels in commercial buildings
• Used for lighting and small motor switching in residential complexes
• Can be used for automation control in manufacturing equipment
• Ideal for HVAC control panels in commercial buildings
• Used for lighting and small motor switching in residential complexes
• Can be used for automation control in manufacturing equipment
What is the pole configuration and how does it affect installation?
It uses a three-pole arrangement, enabling simultaneous interruption of all three phases and simplifying wiring in three-phase systems.
How is the auxiliary contact arranged and what is its purpose?
A single normally open auxiliary contact provides a switched feedback signal for control circuits or interlock schemes.
Which mounting methods are supported to fit different panel layouts?
It can be secured to standard DIN rails or fixed directly to a wall, allowing integration into varied enclosure formats.
What Terminal type is provided for conductor connection?
Screw terminals are used to ensure a reliable mechanical and electrical connection for incoming and outgoing conductors.
Gerelateerde Links
- ABB GJL131 Contactor, 48V Coil, 3-Pole, 20 A, 5.5 kW 48V, 4 NO, 690V dc
- ABB GJL131 Contactor, 48V Coil, 3-Pole, 20 A, 5.5 kW 48V, 3 NO/1 NC, 690V
- ABB GJL131 Contactor, 48V ac Coil, 3-Pole, 20 A, 5.5 kW 48V ac, 4 NO, 690V
- ABB GJL131 Contactor, 48V ac Coil, 4-Pole, 20 A, 5.5 kW 48V ac, 4 NO, 690V
- ABB GJL131 Contactor, 48V ac Coil, 3-Pole, 20 A, 5.5 kW 48V ac, 3 NO/1 NC, 690V
- ABB GJL131 Contactor, 48V ac Coil, 3-Pole, 12 A, 5.5 kW 48V ac, 3 NO/1 NC, 690V
- ABB GJL131 Contactor, 48V ac Coil, 4-Pole, 20 A, 5.5 kW 48V ac, 2 NO/2 NC, 690V
- ABB GJL131 Contactor, 24V Coil, 3-Pole, 20 A, 5.5 kW 24V, 4 NO, 690V