ABB GJL131 Contactor, 48V Coil, 3-Pole, 20 A, 5.5 kW 48V, 3 NO/1 NC, 690V
- RS-stocknr.:
- 253-4834
- Fabrikantnummer:
- GJL1313001R1016
- Fabrikant:
- ABB
Subtotaal (1 verpakking van 10 eenheden)*
€ 361,32
(excl. BTW)
€ 437,20
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Voorradig bij de fabrikant
- Klaar voor verzending vanaf 09 juni 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk | Per verpakking* |
|---|---|---|
| 10 + | € 36,132 | € 361,32 |
*prijsindicatie
- RS-stocknr.:
- 253-4834
- Fabrikantnummer:
- GJL1313001R1016
- Fabrikant:
- ABB
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Product Type | Contactor | |
| Coil Voltage | 48V | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 20A | |
| Power Rating | 5.5kW | |
| Series | GJL131 | |
| Mount Type | DIN Rail, Wall | |
| Function | Mini Contactor | |
| Normal State Configuration | 3 NO/1 NC | |
| Number of Auxiliary Contacts | 1 | |
| Auxiliary Contact Configuration | 0 NO/1 NC | |
| Terminal Type | Screw | |
| Contactor Application | Control Unit | |
| Control Circuit Voltage Uc | 48V | |
| Operational Current Ie | 20A | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | 55°C | |
| Length | 46.7mm | |
| Standards/Approvals | IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | |
| Width | 52.5mm | |
| Depth | 46.7mm | |
| Pole and Throw Configuration | 3P | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Product Type Contactor | ||
Coil Voltage 48V | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 20A | ||
Power Rating 5.5kW | ||
Series GJL131 | ||
Mount Type DIN Rail, Wall | ||
Function Mini Contactor | ||
Normal State Configuration 3 NO/1 NC | ||
Number of Auxiliary Contacts 1 | ||
Auxiliary Contact Configuration 0 NO/1 NC | ||
Terminal Type Screw | ||
Contactor Application Control Unit | ||
Control Circuit Voltage Uc 48V | ||
Operational Current Ie 20A | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature 55°C | ||
Length 46.7mm | ||
Standards/Approvals IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | ||
Width 52.5mm | ||
Depth 46.7mm | ||
Pole and Throw Configuration 3P | ||
ABB GJL131 Series Contactor, 20A Operational Current, 48V Coil Voltage - GJL1313001R1016
This contactor is a Compact switching device designed for control circuits in commercial, industrial and residential electrical installations. It operates as a three-pole switching unit with an additional auxiliary contact to manage control signalling, and is intended for mounting on DIN rail or a wall where Compact, low-profile switching of motors and loads is needed.
Features and Benefits:
• 48V Coil voltage provides consistent actuation for control systems
• 20A operational current supports moderate power loads
• 5.5kW power rating enables direct switching of small motors
• 3NO1NC auxiliary contact for combined switching and signalling
• Screw terminals ensure secure conductor connections
• Conforms to IEC standards for recognised electrical interoperability
• 20A operational current supports moderate power loads
• 5.5kW power rating enables direct switching of small motors
• 3NO1NC auxiliary contact for combined switching and signalling
• Screw terminals ensure secure conductor connections
• Conforms to IEC standards for recognised electrical interoperability
Applications
• Suitable for motor control panels in light industrial plants
• Ideal for building services and HVAC control circuits
• Used with automation relays for process control systems
• Can be used for residential motor starters and load switching
• Ideal for building services and HVAC control circuits
• Used with automation relays for process control systems
• Can be used for residential motor starters and load switching
What mounting options are available for installation?
It can be attached to standard DIN rail or fixed directly to a wall using the provided mounting Interface to suit panel or enclosure arrangements.
What thermal conditions will it tolerate during operation?
The unit is rated to operate between -25°C and 55°C, allowing deployment across typical indoor and sheltered outdoor environments.
How many poles does the device switch and what is the pole arrangement?
The mechanism switches three poles in a 3P arrangement, enabling three-phase or multi-conductor single-phase control.
Which approvals govern its electrical compatibility?
It meets IEC/EN and UL requirements for low-voltage switching including standards for control and power switching devices.
Gerelateerde Links
- ABB GJL131 Contactor, 48V ac Coil, 3-Pole, 12 A, 5.5 kW 48V ac, 3 NO/1 NC, 690V
- ABB GJL131 Contactor, 48V ac Coil, 3-Pole, 20 A, 5.5 kW 48V ac, 3 NO/1 NC, 690V
- ABB GJL131 Contactor, 48V Coil, 3-Pole, 20 A, 5.5 kW 48V, 4 NO, 690V dc
- ABB GJL131 Contactor, 48V ac Coil, 4-Pole, 20 A, 5.5 kW 48V ac, 2 NO/2 NC, 690V
- ABB GJL131 Contactor, 48V ac Coil, 3-Pole, 20 A, 5.5 kW 48V ac, 4 NO, 690V
- ABB GJL131 Contactor, 32V dc Coil, 3-Pole, 20 A, 5.5 kW 690V, 3 NO/1 NC, 690V
- ABB GJL131 Contactor, 48V ac Coil, 4-Pole, 20 A, 5.5 kW 48V ac, 4 NO, 690V