Schneider Electric, TeSys LRD Thermal Overload Relay 1 NO/1 NC, 0.25A, 0.4 A F.L.C, 400mA Contact Rating, 0.09 kW 3
- RS-stocknr.:
- 394-9447
- Fabrikantnummer:
- LRD03
- Fabrikant:
- Schneider Electric
Subtotaal (1 eenheid)*
€ 65,18
(excl. BTW)
€ 78,87
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
- Plus verzending 10 stuk(s) vanaf 27 april 2026
- Plus verzending 7 stuk(s) vanaf 22 mei 2026
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 65,18 |
*prijsindicatie
Better World
Ons Better World assortiment bevat producten die het u gemakkelijk maken om een groenere productkeuze te maken waarop u kunt vertrouwen. Klik hier voor meer informatie.
- RS-stocknr.:
- 394-9447
- Fabrikantnummer:
- LRD03
- Fabrikant:
- Schneider Electric
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Schneider Electric | |
| FLC Motor Rating | 0.25, 0.4A | |
| Product Type | Thermal Overload Relay | |
| Relay Contact Current | 400mA | |
| Mount Type | Direct | |
| Series | TeSys LRD | |
| Pole and Throw Configuration | 3 | |
| Power Rating | 0.09kW | |
| Terminal Type | Screw Clamp | |
| Normal State Configuration | 1 NO/1 NC | |
| IP Rating | IP20 | |
| Reset Method | Automatic & Manual | |
| Width | 45mm | |
| Minimum Operating Temperature | -20°C | |
| Adjustable Current Range | 0.25 to 0.4 A | |
| Number of Auxiliary Contacts | 2 | |
| Contact Voltage | 690V ac | |
| Length | 123mm | |
| Maximum Operating Temperature | 60°C | |
| Depth | 66mm | |
| Standards/Approvals | CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EN 50495, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.4, GB/T 14048.5, UL 60947-4-1, UL 60947-5-1 | |
| Better World Product | Yes | |
| Supply Voltage | 690V ac | |
| Alles selecteren | ||
|---|---|---|
Merk Schneider Electric | ||
FLC Motor Rating 0.25, 0.4A | ||
Product Type Thermal Overload Relay | ||
Relay Contact Current 400mA | ||
Mount Type Direct | ||
Series TeSys LRD | ||
Pole and Throw Configuration 3 | ||
Power Rating 0.09kW | ||
Terminal Type Screw Clamp | ||
Normal State Configuration 1 NO/1 NC | ||
IP Rating IP20 | ||
Reset Method Automatic & Manual | ||
Width 45mm | ||
Minimum Operating Temperature -20°C | ||
Adjustable Current Range 0.25 to 0.4 A | ||
Number of Auxiliary Contacts 2 | ||
Contact Voltage 690V ac | ||
Length 123mm | ||
Maximum Operating Temperature 60°C | ||
Depth 66mm | ||
Standards/Approvals CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EN 50495, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.4, GB/T 14048.5, UL 60947-4-1, UL 60947-5-1 | ||
Better World Product Yes | ||
Supply Voltage 690V ac | ||
Schneider Electric LRD Series Thermal Overload Relay, 0.25 to 0.4 A FLC Motor Rating, 3 Pole Configuration - LRD03
Features & Benefits
Applications
What is the maximum current rating supported for signalling circuits?
How is the reset process configured for this relay?
What kind of mounting support is available for this relay?
What is the significance of having a trip threshold of 1.14 +/- 0.06 Ir?
Gerelateerde Links
- Schneider Electric, TeSys LRD Thermal Overload Relay 1 NO/1 NC, 65A F.L.C, 5A Contact Rating, 690V ac 3P
- Schneider Electric, TeSys LRD Thermal Overload Relay 1 NO/1 NC, 6A F.L.C, 5A Contact Rating, 690V ac 3
- Schneider Electric, TeSys LRD Thermal Overload Relay 1 NO/1 NC, 6A F.L.C, 5A Contact Rating, 2.2 kW, 690V ac 3
- Schneider Electric, TeSys LRD Thermal Overload Relay 1 NO/1 NC, 13A F.L.C, 5A Contact Rating, 5.5 kW, 690V ac 3
- Schneider Electric, TeSyS LR Thermal Overload Relay 1 NO/1 NC, 0.4A F.L.C, 5A Contact Rating, 0.09 kW, 690V ac 3
- Schneider Electric, TeSys LRD Thermal Overload Relay 1 NO/1 NC, 300 mW, 690V 3P
- Schneider Electric, LRD Thermal Overload Relay 1 NO/1 NC, 1A Contact Rating, 690V ac
- Schneider Electric, TeSys LRD Overload Relay 1 NO/1 NC, 250mA Contact Rating, 0.06 kW 3