Schneider Electric, LRD Thermal Overload Relay 1 NO/1 NC, Trip Dial: 30 → 40 A, 30A, 40 A F.L.C, 40A Contact Rating, 22
- RS-stocknr.:
- 727-6210
- Fabrikantnummer:
- LRD340
- Fabrikant:
- Schneider Electric
Subtotaal (1 eenheid)*
€ 109,99
(excl. BTW)
€ 133,09
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
- Plus verzending 21 stuk(s) vanaf 23 november 2026
- Plus verzending 57 stuk(s) vanaf 23 november 2026
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 109,99 |
*prijsindicatie
- RS-stocknr.:
- 727-6210
- Fabrikantnummer:
- LRD340
- Fabrikant:
- Schneider Electric
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Schneider Electric | |
| Product Type | Thermal Overload Relay | |
| FLC Motor Rating | 30A, 40A | |
| Relay Contact Current | 40A | |
| Series | LRD | |
| Mount Type | Under Contactor Mount | |
| Power Rating | 22kW | |
| Pole and Throw Configuration | 3 | |
| Terminal Type | Screw | |
| Normal State Configuration | 1 NO/1 NC | |
| Reset Method | Push Button | |
| IP Rating | IP20 | |
| Minimum Operating Temperature | -20°C | |
| Width | 55mm | |
| Adjustable Current Range | 30 → 40 A | |
| Number of Auxiliary Contacts | 2 | |
| Length | 70mm | |
| Contact Voltage | 1kV ac | |
| Maximum Operating Temperature | 60°C | |
| Depth | 116mm | |
| Standards/Approvals | UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EN 50495, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.4, GB/T 14048.5, UL 60947-4-1 | |
| Supply Voltage | 690V | |
| Alles selecteren | ||
|---|---|---|
Merk Schneider Electric | ||
Product Type Thermal Overload Relay | ||
FLC Motor Rating 30A, 40A | ||
Relay Contact Current 40A | ||
Series LRD | ||
Mount Type Under Contactor Mount | ||
Power Rating 22kW | ||
Pole and Throw Configuration 3 | ||
Terminal Type Screw | ||
Normal State Configuration 1 NO/1 NC | ||
Reset Method Push Button | ||
IP Rating IP20 | ||
Minimum Operating Temperature -20°C | ||
Width 55mm | ||
Adjustable Current Range 30 → 40 A | ||
Number of Auxiliary Contacts 2 | ||
Length 70mm | ||
Contact Voltage 1kV ac | ||
Maximum Operating Temperature 60°C | ||
Depth 116mm | ||
Standards/Approvals UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EN 50495, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.4, GB/T 14048.5, UL 60947-4-1 | ||
Supply Voltage 690V | ||
- Land van herkomst:
- FR
Schneider Electric LRD Series Thermal Overload Relay, 30 to 40 A Motor Rating, Automatic Reset Method - LRD340
Features & Benefits
Applications
What is the significance of the 30 to 40A adjustment range?
How does the automatic reset function work?
Can it be used with different types of networks?
What type of terminals does this device feature?
What is the impact of the rated operational voltage?
Standards
Gerelateerde Links
- Schneider Electric, LRD Thermal Overload Relay 1 NO/1 NC, Trip Dial: 30 → 40 A, 30A, 40 A F.L.C, 40A Contact Rating,
- Schneider Electric, LRD Thermal Overload Relay 1 NO/1 NC, Trip Dial: 30 → 38 A, 30A, 38 A F.L.C, 38A Contact Rating,
- Schneider Electric, D Overload Relay 1 NO/1 NC, Trip Dial: 30 → 40 A, 25A, 40 A F.L.C, 40A Contact Rating, 22 kW 3
- Schneider Electric, LRD Overload Relay 1 NO/1 NC, Trip Dial: 17 → 25 A, 17A, 25 A F.L.C, 25A Contact Rating
- Schneider Electric, LRD Overload Relay 1 NO/1 NC, Trip Dial: 0.4 → 0.63 A, 400mA, 630 mA F.L.C, 630mA Contact Rating,
- Schneider Electric, LRD Thermal Overload Relay 1 NO/1 NC, Trip Dial: 0.25 → 0.4 A, 250mA, 400 mA F.L.C, 400mA Contact
- Schneider Electric, LRD Overload Relay 1 NO/1 NC, Trip Dial: 0.16 → 0.25 A, 160mA, 250 mA F.L.C, 250mA Contact Rating,
- Schneider Electric, LRD Thermal Overload Relay 1 NO/1 NC, Trip Dial: 80 → 104 A, 104A, 80 A F.L.C, 104A Contact Rating,