ABB, 26.7 mm Nominal Diameter, High Temperature Thermoplastic, Galvanised Steel, White
- RS-stocknr.:
- 266-4473
- Fabrikantnummer:
- 7TCA296030R0516
- Fabrikant:
- ABB
Subtotaal (1 rol van 25 meter)*
€ 2.987,61
(excl. BTW)
€ 3.615,01
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Voorradig bij de fabrikant
- Klaar voor verzending vanaf 04 juni 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len) | Per rol | Per meter* |
|---|---|---|
| 1 + | € 2.987,61 | € 119,504 |
*prijsindicatie
- RS-stocknr.:
- 266-4473
- Fabrikantnummer:
- 7TCA296030R0516
- Fabrikant:
- ABB
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Product Type | Flexible Conduit | |
| Nominal Diameter | 26.7mm | |
| Coating Material | High Temperature Thermoplastic | |
| Material | Galvanised Steel | |
| Series | Adaptaflex | |
| Colour | White | |
| Length | 25m | |
| IP Rating | IP69, IP68 | |
| Thread Size | 16 mm | |
| Resistance Features | Liquid Resistant | |
| Minimum Operating Temperature | -50°C | |
| Maximum Operating Temperature | 130°C | |
| Standards/Approvals | REACH, RoHS, CE | |
| Hazardous Area Certification | ATEX | |
| Minimum Bend Radius | 80mm | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Product Type Flexible Conduit | ||
Nominal Diameter 26.7mm | ||
Coating Material High Temperature Thermoplastic | ||
Material Galvanised Steel | ||
Series Adaptaflex | ||
Colour White | ||
Length 25m | ||
IP Rating IP69, IP68 | ||
Thread Size 16 mm | ||
Resistance Features Liquid Resistant | ||
Minimum Operating Temperature -50°C | ||
Maximum Operating Temperature 130°C | ||
Standards/Approvals REACH, RoHS, CE | ||
Hazardous Area Certification ATEX | ||
Minimum Bend Radius 80mm | ||
Vrijgesteld
- Land van herkomst:
- GB
ABB Adaptaflex Series Flexible Conduit, 32mm Nominal Diameter, White - 7TCA296030R0516
This flexible conduit provides protected routing for cables and wiring in demanding industrial environments. Designed for use where elevated temperatures, liquid exposure and regulatory compliance are considerations, it combines a galvanised steel core with a high-temperature thermoplastic outer layer to maintain mechanical integrity and environmental resistance across harsh duty cycles.
Features and Benefits:
• Withstands continuous use up to 130°C for high-temperature applications
• Operates down to -50°C for cold-environment installation reliability
• Offers liquid resistance to protect conductors in wet conditions
• Complies with REACH and RoHS to meet materials restrictions
• Supplied in a 25 m length for extended runs without joins
• IP40 and IP69 ratings for protection against ingress and washdown
• Operates down to -50°C for cold-environment installation reliability
• Offers liquid resistance to protect conductors in wet conditions
• Complies with REACH and RoHS to meet materials restrictions
• Supplied in a 25 m length for extended runs without joins
• IP40 and IP69 ratings for protection against ingress and washdown
Applications
• Suitable for automation cabinets exposed to heat and moisture
• Ideal for routing cables in food processing washdown areas
• Used with electrical installations requiring hazardous-area certification
• Can be used for machinery wiring where low-temperature resilience is needed
• Ideal for routing cables in food processing washdown areas
• Used with electrical installations requiring hazardous-area certification
• Can be used for machinery wiring where low-temperature resilience is needed
What construction provides mechanical protection against impact?
The conduit uses a galvanised steel inner structure that gives crush and impact resistance while allowing flexibility for routed runs.
How is attachment to equipment achieved where threads are needed?
The product accepts fittings with a 16mm thread size to enable secure connections to glands and enclosures.
Which environmental standards govern suitability for explosive atmospheres?
It holds an ATEX hazardous-area certification indicating it meets required safety criteria for specified explosive atmospheres.
How does the conduit cope with regulatory material limits?
The materials used conform to REACH and RoHS standards, restricting certain hazardous substances in components.
What diameters and bend characteristics affect routing in confined spaces?
The conduit has a 32mm nominal diameter and requires a minimum bend radius of 80mm to preserve cable integrity.
Gerelateerde Links
- ABB, 21.1 mm Nominal Diameter, High Temperature Thermoplastic, Galvanised Steel, White
- ABB, 17.8 mm Nominal Diameter, High Temperature Thermoplastic, Galvanised Steel, White
- ABB, 26.4 mm Nominal Diameter, High Temperature Thermoplastic, Galvanised Steel, White
- ABB, 25 mm Nominal Diameter, High Temperature Thermoplastic, Galvanised Steel, White
- ABB, 32 mm Nominal Diameter, High Temperature Thermoplastic, Galvanised Steel, White
- ABB, 16 mm Nominal Diameter, High Temperature Thermoplastic, Galvanised Steel, White
- ABB, 20 mm Nominal Diameter, High Temperature Thermoplastic, Galvanised Steel, White
- ABB, 16 mm Nominal Diameter, Thermoplastic Rubber Extreme Temperature, Galvanised Steel, Black