Alpha Wire Alpha Essentials Data & Bus Cable Series Data Cable, 1 Pairs, 2 Cores, 0.462 mm², Screened, 22 AWG, 30m,

Subtotaal (1 rol van 30 meter)*

€ 119,39

(excl. BTW)

€ 144,46

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 18 stuk(s) klaar voor verzending
  • 17 stuk(s) klaar voor verzending vanaf een andere locatie
  • Plus verzending 10 stuk(s) vanaf 09 februari 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len)
Per rol
Per meter*
1 +€ 119,39€ 3,98

*prijsindicatie

RS-stocknr.:
749-1627
Fabrikantnummer:
6453 BK005
Fabrikant:
Alpha Wire
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Alpha Wire

Number of Pairs

1

Cross Sectional Area

0.462 mm²

Number of Cores

2

American Wire Gauge

22 AWG

Screened/Unscreened

Screened

Length

30m

Shield Type

Foil and Braid

Sheath Colour

Black

Cable Type

RS-485

Outer Diameter

7.21mm

Outer Sheath Material

PVC

Cable Shape

Twisted Pair

Characteristic Impedance

120 Ω

Series

Alpha Essentials Data & Bus Cable

Core Strands

7/30 AWG

Fire Behaviour

Fire Resistant

Voltage Rating

300 V

Standards Met

CE, CSA, UL

Belden Alpha Wire 1 Twisted Pair RS-485 Data Cable, 0.462mm² CSA - Alpha Essentials Series - 6453


Relay information between devices without the risk of crosstalk with this data cable from Belden's Alpha Wire range. Its twisted-pair design minimises disruption from EMI (electromagnetic interference) to deliver a reliable data connection. The tinned-copper conductors are resistant to corrosion, making this cable ideal for use in damp or humid conditions. It also benefits from a combination of aluminium mylar foil and braided tinned-copper shielding, which gives extra protection against the external EMI (electromagnetic interference) often found in heavily automated applications.

Features & Benefits


• PVC cable jacket protects against friction and wear in heavy-duty applications
• Operating temperature range between -20°C and +60°C for use in demanding conditions
• Comes on a reel for convenient handling and neat storage

Applications


• Control and automation systems
• Automotive industry
• Packaging and logistics

How do twisted-pair cables reduce disruption from EMI?


When a wire carries an electric current, it generates an electromagnetic field that causes EMI. A twisted-pair design helps reduce this effect by making the paired wires carry signals in opposing directions, meaning the two magnetic fields generated cancel each other out.