Alpha Wire Pro-Tekt Series Data Cable, 19 Pairs, 0.23 mm², 50 m, Grey Sheath Polyvinyl Chloride

Subtotaal (1 rol van 50 meter)*

€ 646,10

(excl. BTW)

€ 781,78

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Tijdelijk niet op voorraad
  • Verzending vanaf 07 september 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len)
Per rol
Per meter*
1 +€ 646,10€ 12,922

*prijsindicatie

RS-stocknr.:
740-4951
Fabrikantnummer:
B963194 GE321
Fabrikant:
Alpha Wire
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Alpha Wire

Product Type

Data Cable

Number of Pairs

19

Cross Sectional Area

0.23mm²

Cable Length

50m

Jacket Colour

Grey

Outside Diameter

11.58mm

Minimum Operating Temperature

-30°C

Jacket Material

Polyvinyl Chloride

Conductor Type

Copper

Maximum Operating Temperature

105°C

Standards/Approvals

CE, CSA Certified, UL

Voltage

300V

Core Strands

7

Fire Behaviour

Flame Retardant

Conductor Material

Tin Copper Wire

Series

Pro-Tekt

Belden Pro-Tekt Series Data Cable, 50m Cable Length, Grey Jacket - B963194 GE321


This data cable is a multi-pair communication cable designed for industrial signal and control installations, offering temperature resilience and flame-retardant construction for demanding environments. It combines multiple twisted pairs with a comprehensive shielding system and a grey PVC outer sheath to support reliable signal transmission in automation and electrical applications.

Features & Benefits


• 19 twisted pairs delivering organised multi-channel signalling
• Tin-plated 7-strand conductors for flexible connectivity
• 300V voltage rating suitable for control circuits
• Flame-retardant jacket for enhanced fire performance
• Rated to operate from -30°C to 105°C for harsh sites
• Overall braid and tape shield for noise suppression

**Applications**


• Suitable for factory automation control wiring
• Ideal for cabinet internal signal distribution
• Used for interconnects in process control systems
• Can be used for multi-drop sensor and actuator networks
• Suitable for retrofit installations in industrial machinery

How is the cable constructed to reduce electromagnetic interference?


Each pair is selectively cabled with a dedicated drain conductor and an overall tape Plus a braided copper shield with minimum 70% coverage to attenuate external noise.

What are the electrical transmission characteristics relevant for system design?


Characteristic impedance is approximately 82 Ω, mutual capacitance around 23.1 pF/ft, and conductor DCR is about 26 Ω/1000 ft at 20°C for load calculations.

How is the cable marked and sized for inventory control?


The jacket is printed with manufacturer and part identification along with conductor size noted as 0.23 mm² to assist stock management.

What mechanical handling limits should installers observe?


The recommended minimum bend radius is 10 x cable diameter and maximum pull tension is 144 lb to avoid damage.

How does the outer material support outdoor or exposed routing?


The PVC jacket provides sunlight resistance and includes a ripcord for easy jacket removal during termination.