Schneider Electric TeSys Thermal Circuit Breaker - GB2 2 Pole 277V ac Voltage Rating DIN Rail Mount, 6A Current Rating
- RS-stocknr.:
- 312-3831
- Fabrikantnummer:
- GB2DB12
- Fabrikant:
- Schneider Electric
Subtotaal (1 eenheid)*
€ 47,07
(excl. BTW)
€ 56,95
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Op voorraad
- Plus verzending 19 stuk(s) vanaf 15 december 2025
- Plus verzending 9 stuk(s) vanaf 15 december 2025
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 47,07 |
*prijsindicatie
- RS-stocknr.:
- 312-3831
- Fabrikantnummer:
- GB2DB12
- Fabrikant:
- Schneider Electric
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Schneider Electric | |
| Current Rating | 6A | |
| Range | TeSys | |
| Number of Poles | 2 | |
| Voltage Rating | 277 V ac, 415V ac | |
| Width | 30mm | |
| Series | GB2 | |
| Mounting Style | DIN Rail Mount | |
| Overall Depth | 85mm | |
| Overall Length | 74mm | |
| Circuit Breaker Type | Thermal Magnetic Circuit Breaker | |
| Overall Dimensions | 74 x 30 x 85mm | |
| Breaking Capacity at Maximum Voltage Rating | 1 (dc) kA, 1.5 (ac) kA | |
| Alles selecteren | ||
|---|---|---|
Merk Schneider Electric | ||
Current Rating 6A | ||
Range TeSys | ||
Number of Poles 2 | ||
Voltage Rating 277 V ac, 415V ac | ||
Width 30mm | ||
Series GB2 | ||
Mounting Style DIN Rail Mount | ||
Overall Depth 85mm | ||
Overall Length 74mm | ||
Circuit Breaker Type Thermal Magnetic Circuit Breaker | ||
Overall Dimensions 74 x 30 x 85mm | ||
Breaking Capacity at Maximum Voltage Rating 1 (dc) kA, 1.5 (ac) kA | ||
Niet conform
- Land van herkomst:
- FR
Schneider Electric GB2 Series Thermal Circuit Breaker, 6A Current Rating, 415V Rated Voltage - GB2DB12
This thermal circuit breaker is designed specifically for control circuit protection within automation and electrical systems. Engineered to accommodate a current rating of 6A, it features a compact DIN rail-mounted design. Its balanced dimensions of 74mm in length, 30mm in width, and 85mm in depth ensure seamless integration in various electrical panels.
Features & Benefits
• 2 pole circuit breaker effectively isolates control circuits
• Thermal-magnetic tripping mechanism enhances reliability
• Rated operational voltage of 415V AC supports high demand
• Breaking capacity of 1.5kA at 415V assists in safeguarding systems
• Durable for 8000 electrical and mechanical cycles
• Versatile mounting options for horisontal or vertical installations
• Thermal-magnetic tripping mechanism enhances reliability
• Rated operational voltage of 415V AC supports high demand
• Breaking capacity of 1.5kA at 415V assists in safeguarding systems
• Durable for 8000 electrical and mechanical cycles
• Versatile mounting options for horisontal or vertical installations
Applications
• Used with control circuits in automation systems
• Suitable for 415V AC voltage networks
• Ideal for installations requiring DIN rail mounting
• Utilised in various environments with temperature ranges from -20°C to 60°C
• Suitable for 415V AC voltage networks
• Ideal for installations requiring DIN rail mounting
• Utilised in various environments with temperature ranges from -20°C to 60°C
How does the thermal-magnetic tripping mechanism improve functionality?
The thermal-magnetic tripping mechanism provides dual protection by reacting to both overcurrent conditions and electromechanical faults, ensuring timely disconnection to prevent equipment damage.
What are the connection terminal specifications?
The device features terminals accommodating solid wires from 0.75mm² to 6mm² without cable ends and for flexible wires with cable ends, making it versatile for various installation needs.
What is the significance of its IP20 rating?
An IP20 rating indicates protection against solid objects greater than 12mm, making it suitable for indoor environments where exposure to water or dust is minimal.
What are the implications of its ambient temperature rating?
The operational range of -20°C to 60°C ensures reliable performance in various climates, making it suitable for diverse industrial applications.
How many units are typically included in a package for bulk ordering?
The thermal circuit breaker is commonly packaged in sets of three for bulk orders, allowing for efficient project planning and procurement.
Gerelateerde Links
- Schneider Electric Thermal Circuit Breaker - GB2 Single Pole 277V ac Voltage Rating DIN Rail Mount, 6A Current Rating
- Schneider Electric TeSys Thermal Circuit Breaker - GB2 2 Pole 277V ac Voltage Rating DIN Rail Mount, 2A Current Rating
- Schneider Electric TeSys Thermal Circuit Breaker - GB2 2 Pole 277V ac Voltage Rating DIN Rail Mount, 10A Current Rating
- Schneider Electric TeSys Thermal Circuit Breaker - GB2 2 Pole 250V Voltage Rating, 16A Current Rating
- Schneider Electric TeSys Thermal Circuit Breaker - GB2 2 Pole 250V Voltage Rating, 12A Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 2 Pole 277V ac Voltage Rating DIN Rail Mount, 16A Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 2 Pole 277V ac Voltage Rating DIN Rail Mount, 500mA Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 2 Pole 277V ac Voltage Rating DIN Rail Mount, 3A Current Rating