Better World
Schneider Electric TeSys Thermal Circuit Breaker - TeSyS GV 3 Pole 690V Voltage Rating DIN Rail Mount, 13A Current
- RS Stock No.:
- 272-886
- Mfr. Part No.:
- GV3P13
- Brand:
- Schneider Electric
Subtotal (1 unit)*
€ 167,53
(exc. VAT)
€ 202,71
(inc. VAT)
GRATIS bezorging voor bestellingen vanaf € 75,00
Op voorraad
- Plus verzending 10 stuk(s) vanaf 15 december 2025
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Units | Per unit |
|---|---|
| 1 + | € 167,53 |
*price indicative
Better World
Ons Better World assortiment bevat producten die het u gemakkelijk maken om een groenere productkeuze te maken waarop u kunt vertrouwen. Klik hier voor meer informatie.
- RS Stock No.:
- 272-886
- Mfr. Part No.:
- GV3P13
- Brand:
- Schneider Electric
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Merk | Schneider Electric | |
| Current Rating | 13A | |
| Number of Poles | 3 | |
| Range | TeSys | |
| Voltage Rating | 690V | |
| Width | 55mm | |
| Series | TeSyS GV | |
| Application | Motors | |
| Tripping Mechanism | Thermal-Magnetic | |
| Rated AC Voltage | 690V | |
| Mounting Style | DIN Rail Mount | |
| Better World Product | Yes | |
| Better World Verification | Green Premium | |
| Breaking Capacity at Maximum Voltage Rating | 6 kA | |
| Terminal Contact Type | Screw | |
| Overall Depth | 136mm | |
| Circuit Breaker Type | Thermal Magnetic Circuit Breaker | |
| Overall Dimensions | 132 x 55 x 136mm | |
| Overall Length | 132mm | |
| Select all | ||
|---|---|---|
Merk Schneider Electric | ||
Current Rating 13A | ||
Number of Poles 3 | ||
Range TeSys | ||
Voltage Rating 690V | ||
Width 55mm | ||
Series TeSyS GV | ||
Application Motors | ||
Tripping Mechanism Thermal-Magnetic | ||
Rated AC Voltage 690V | ||
Mounting Style DIN Rail Mount | ||
Better World Product Yes | ||
Better World Verification Green Premium | ||
Breaking Capacity at Maximum Voltage Rating 6 kA | ||
Terminal Contact Type Screw | ||
Overall Depth 136mm | ||
Circuit Breaker Type Thermal Magnetic Circuit Breaker | ||
Overall Dimensions 132 x 55 x 136mm | ||
Overall Length 132mm | ||
Schneider Electric TeSys GV3 (GV3P) Series Motor Protection Circuit Breaker.
TeSys GV3 motor protection circuit breakers protect your motors from faults such as an overload of high voltage, short circuits, or relay shutdowns is vital in an age where any downtime can be detrimental to a business and its operations. Schneider Electric has built a reliable, robust series known as the GV3P series of Motor Protection Circuit Breaker to act as an intermediary between your devices, protecting vital equipment in the event of unforeseen incidents. TeSys GV3 circuit breakers include Everlink power terminal system with excellent connection quality ensuring any cable tightening pressure remains secure in any environment.
Features and benefits.
- Easy integration with all configurations with a 55mm standard width and DIN rail fixing.
- Everlink terminals
- GV3 P Thermal magnetic breaker.7 Ratings from 25 A to 65 A for magnetic and thermal motor protection (5.5 kW to 30 kW).
- 50 kA Icu breaking capacity from 40 A to 65 A (100 kA Icu from 9 A to 32 A).
- Space saving and easy installation.
- 3 Position rotary switch / knob.
- Front face padlocking.
- Strong cable connection.
- Performs well in tough environments.
- Simple and easy to install.
- Trip test button.
- Sealable flap for protection of thermal setting.
- Reduced downtime.
- IP and IK Rated.
- Forms part of the TeSys range of products, known as the TeSys GV3P (Green Premium).
Applications.
- Industry
- Infrastructure
- Buildings
- Easily assembled into any configuration by screw or clip-fixing onto mounting rails.
How do you select the right Motor Protection Circuit Breaker?
MPCBs are more critical now than ever. Most infrastructure now relies on a motor behind the scenes to power critical uninterruptible systems such as heating, ventilation, cooling all of which we take for granted. These systems are vital in ensuring business productivity and therefore must be protected against overcurrent, thermal overloads and much more.
To select the right MPCB, consider the systems you and your business rely upon. Checking the features and benefits of each MPCB will prove invaluable when deciding what critical infrastructure, you wish to protect.
To select the right MPCB, consider the systems you and your business rely upon. Checking the features and benefits of each MPCB will prove invaluable when deciding what critical infrastructure, you wish to protect.
Standards
IEC 947 and UL 508 type E certification
Related links
- Schneider Electric TeSys Thermal Circuit Breaker - TeSyS GV 3 Pole 690V ac Voltage Rating, 80A Current Rating
- Schneider Electric TeSys Thermal Circuit Breaker - TeSyS GV 3 Pole 690V ac Voltage Rating, 25A Current Rating
- Schneider Electric TeSys Thermal Circuit Breaker - TeSyS GV 3 Pole 690V ac Voltage Rating, 115A Current Rating
- Schneider Electric TeSys Thermal Circuit Breaker - TeSyS GV 3 Pole 690V ac Voltage Rating, 12.5A Current Rating
- Schneider Electric TeSys Thermal Circuit Breaker - TeSyS GV 3 Pole 690V ac Voltage Rating, 2A Current Rating
- Schneider Electric TeSys Thermal Circuit Breaker - TeSyS GV 3 Pole 690V ac Voltage Rating, 3.5A Current Rating
- Schneider Electric TeSys Thermal Circuit Breaker - TeSyS GV 3 Pole 690V ac Voltage Rating, 7A Current Rating
- Schneider Electric TeSys Thermal Circuit Breaker - TeSyS GV 3 Pole 690V ac Voltage Rating, 50A Current Rating
