Time Electronics 1090 Temperature Calibrator, With UKAS Calibration

Subtotaal (1 eenheid)*

€ 2.160,66

(excl. BTW)

€ 2.614,40

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 3 stuk(s) klaar voor verzending
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 2.160,66

*prijsindicatie

RS-stocknr.:
410-2166
Fabrikantnummer:
1090
Fabrikant:
Time Electronics
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Time Electronics

Calibrator Type

Thermocouple Calibrator

Resolution

0.1 °C, 0.1 °F

Best Accuracy

0.2 °C

Thermocouple Type

B, E, J, K, N, R, S, T

Temperature Scale

Centigrade, Fahrenheit

B Type Thermocouple Maximum Temperature

+1800°C

Calibrated

UKAS

B Type Thermocouple Minimum Temperature

110°C

E Type Thermocouple Maximum Temperature

+400°C

E Type Thermocouple Minimum Temperature

50°C

J Type Thermocouple Maximum Temperature

580°C

K Type Thermocouple Maximum Temperature

+750°C

K Type Thermocouple Minimum Temperature

-200°C

Model Number p

1090

J Type Thermocouple Temperature Range

-200 → +580 °C

T Type Thermocouple Temperature Range

-200 → +400 °C

K Type Thermocouple Temperature Range

-200 → +750 °C

B Type Thermocouple Temperature Range

+110 → +1800 °C

Length

75mm

Width

150mm

E Type Thermocouple Temperature Range

-50 → +400 °C

R Type Thermocouple Temperature Range

+50 → +1750 °C

Dimensions

75 x 150 x 235mm

S Type Thermocouple Temperature Range

-50 → +1750 °C

Height

235mm

Weight

1.2kg

Vrijgesteld

Land van herkomst:
GB

Temperature & mV/mA Calibrator 1090


A high performance portable instrument combining source and measure functions for thermocouples, Pt100, mV and mA.

Measures/simulates 8 thermocouple types J, K, T, R, S, B, N, E: Pt100, mV and mA
Displays in selectable units in °C/°F, uV/m
Large backlit super-twist LCD display, 7.5 mm digits
Sealed membrane keypad
Automatic or manual cold junction compensation
Memory storage of frequently used values
Sturdy carrying case with test lead compartment
Equivalent converted uV/Pt 100 resistance can be displayed on both source & measure
Rechargeable battery 50+ hrs use. Auto power save button
Auto step function with configurable step time
24V process loop drive mode

Note

Pt100 simulation: 14 set values to within ±0.1% of DIN43760, -100, -50, -20, 0, 20, 50, 100, 200, 300, 400, 500, 600, 700, 800 deg C.Pt 100 Measure: 20Ω (-200 °C) to 350Ω (700 °C) accuracy:±0.5%

Supplied with

carry case and mains recharger

Gerelateerde Links