Eaton 160A Bolted Tag Fuse, LET, 150 V dc, 240V ac, 41mm

Subtotaal (1 doos van 10 eenheden)*

€ 218,97

(excl. BTW)

€ 264,95

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 50 stuk(s) klaar voor verzending vanaf een andere locatie
  • Plus verzending 10 stuk(s) vanaf 23 december 2025
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
Per Doos*
10 +€ 21,897€ 218,97

*prijsindicatie

RS-stocknr.:
182-1425
Artikelnummer Distrelec:
303-96-418
Fabrikantnummer:
160LET
Fabrikant:
Eaton
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Eaton

Current Rating

160A

Fuse Size

LET

Voltage Rating

150 V dc, 240V ac

Fuse Standard

BS 88, IEC 269-4

Fixing Centres

41mm

Application Category

aR

Tag Width

12.7mm

High Rupture Capacity

Yes

Overall Length

55mm

Tag Type

Bolted

Body Diameter

17.7mm

Tag Orientation

Offset

Body Length

26.2mm

Body Height

19.1mm

Fuse Dimensions

17.7 x 26.2mm

Land van herkomst:
IN

Eaton British Standard Fuse, 160A Current Rating, 240V AC Voltage Rating - 160LET


This British Standard Fuse is designed for high-speed protection in various electrical applications. This fuse boasts a current rating of 160A and meets the BS 88 and IEC 269-4 standards. With a compact size of 55 x 18 x 18 mm, it features an offset bolted tag design, ensuring secure mounting and reliable performance.

Features & Benefits


• High rupture capacity allows for robust protection against faults
• Rated for both 280V AC and 150V DC use for versatility
• Designed with a 41.5mm centre-to-centre distance for easy installation
• Utilisation category aR offers semiconductor protection
• Suitable for various applications, including power converters and drives

Applications


• Utilised in semiconductor environments to manage power distribution
• Ideal for connecting DC drives and common bus systems
• Implemented in power converters and rectifiers for efficient operation

What are the advantages of using this type of electrical component?


The design offers high rupture capacity, enhancing safety in electrical systems by effectively managing fault conditions and preventing damage to other components.

How does the breaking capacity influence performance in real-world situations?


With a breaking capacity of 200kA, it can handle significant fault currents, ensuring protection during unexpected overload scenarios, thus safeguarding connected equipment.

What connections are compatible with this fuse model?


The fuse supports blade end connections, making it versatile for various installation needs, facilitating seamless integration into existing electrical setups.

Note

Eaton formerly known as Bussmann