Celduc SO9 Series Solid State Relay, 25 A Load, Panel Mount, 280 V ac Load, 265V ac/dc Control

Bulkkorting beschikbaar

Subtotaal (1 eenheid)*

€ 39,78

(excl. BTW)

€ 48,13

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • Plus verzending 19 stuk(s) vanaf 15 december 2025
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 - 4€ 39,78
5 - 9€ 38,17
10 +€ 37,39

*prijsindicatie

RS-stocknr.:
917-4810
Fabrikantnummer:
SO942960
Fabrikant:
Celduc
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Celduc

Maximum Load Current

25 A

Mounting Type

Panel Mount

Maximum Load Voltage

280 V ac

Minimum Load Voltage

12 V ac

Minimum Control Voltage

185V ac/dc

Maximum Control Voltage

265V ac/dc

Switching Type

Zero Cross

Control Voltage Range

185 → 265 V ac/dc

Minimum Load Current

5 mA

Range

SO9

Number of Poles

1

Terminal Type

Screw

Output Device

Triac

Relay Type

AC

Series

SO9

Load Voltage Range

12 → 280V ac

Maximum Turn On Time

30ms

Dimensions

44.8 x 59.4 x 30mm

Maximum Operating Temperature

+100°C

Minimum Operating Temperature

-55°C

Standards Met

CE, EAC, cURus

Height

30mm

Off State Leakage Current

1 mA

Length

44.8mm

Operating Temperature Range

-55 → +100°C

Depth

59.4mm

Special Features

Zero Cross Solid State Relay Especially Designed for Resistive Loads, Green LED Visualization on The Input, IP20 Protection By Removable Flaps on Terminals with Optional Labels

Land van herkomst:
FR

Single-phase solid state relays, SO9 series


Synchronous solid state relay suited to most loads.
TMS2 technology thyristor output ensures longevity.
Voltage protection for input as well as output (VDR) for very high immunity to interference.
Wide control range: 20 → 265 Vac / dc with regulated control current.
Green LED input display.
Solid state relays must be mounted on a heatsink.

Standards

EN60947-4-3 and EN60950


Instantaneous Switching

Note

Temperature can affect current rating; please consult the data sheet for potential derating.