RS PRO 1.65 kVA Intermittent 5 Mins on 15 Mins off Site Transformer, 230V ac Primary, 110 (55V Secondary, 2 x 16A O/P
- RS-stocknr.:
- 122-6706
- Artikelnummer Distrelec:
- 304-25-253
- Fabrikant:
- RS PRO
Subtotaal (1 eenheid)*
€ 326,66
(excl. BTW)
€ 395,26
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Op voorraad
- 18 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 326,66 |
*prijsindicatie
- RS-stocknr.:
- 122-6706
- Artikelnummer Distrelec:
- 304-25-253
- Fabrikant:
- RS PRO
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | RS PRO | |
| Primary Voltage Rating | 230V ac | |
| Secondary Voltage Rating | 110 (55V-0V-55V)V | |
| Power Rating | 1.65 kVA Intermittent 5 Mins on 15 Mins off | |
| Output Current | 2 x 16A | |
| Socket Type | BS EN 60309 | |
| Length | 270mm | |
| Width | 228mm | |
| Depth | 244mm | |
| Dimensions | 270 x 228 x 244mm | |
| Mounting Type | Wall Mount | |
| Maximum Operating Frequency | 50Hz | |
| Minimum Operating Frequency | 50Hz | |
| Alles selecteren | ||
|---|---|---|
Merk RS PRO | ||
Primary Voltage Rating 230V ac | ||
Secondary Voltage Rating 110 (55V-0V-55V)V | ||
Power Rating 1.65 kVA Intermittent 5 Mins on 15 Mins off | ||
Output Current 2 x 16A | ||
Socket Type BS EN 60309 | ||
Length 270mm | ||
Width 228mm | ||
Depth 244mm | ||
Dimensions 270 x 228 x 244mm | ||
Mounting Type Wall Mount | ||
Maximum Operating Frequency 50Hz | ||
Minimum Operating Frequency 50Hz | ||
- Land van herkomst:
- GB
RS PRO, 1.65 kVA Safety Transformer, 230 V AC, 2 x 16 A
This safety transformer from RS PRO is designed to provide a safe power supply for tools and other appliances in garages or industrial settings. The continuous single-phase transformer has a 230 V AC input and 110 V AC output, so you can step the voltage down. This means you're in control in the event of a hazard such as a cable being cut.
The transformer features a 110 V secondary winding centre-tapped to earth for additional safety. There are mounting flanges and conduit entry points to make for easy installation and use. A thermal magnetic trip reduces the risk of overload. The device is housed in a robust steel enclosure that's IP22-rated, so your fingers can't get inside and water can't drip in.
The transformer features a 110 V secondary winding centre-tapped to earth for additional safety. There are mounting flanges and conduit entry points to make for easy installation and use. A thermal magnetic trip reduces the risk of overload. The device is housed in a robust steel enclosure that's IP22-rated, so your fingers can't get inside and water can't drip in.
Features and Benefits
• Length of 270 mm
• Depth of 244 mm
• Width of 228 mm
• Maximum operating frequency of 50 Hz
• Minimum operating frequency of 50 Hz
• Power rating of 1.65 kVA
• BS EN 60309 socket
• Primary voltage rating of 240 V AC
• Secondary voltage rating of 0 to 240 V AC
• Output current of 2 x 16 A
• Wall-mounting type
• Depth of 244 mm
• Width of 228 mm
• Maximum operating frequency of 50 Hz
• Minimum operating frequency of 50 Hz
• Power rating of 1.65 kVA
• BS EN 60309 socket
• Primary voltage rating of 240 V AC
• Secondary voltage rating of 0 to 240 V AC
• Output current of 2 x 16 A
• Wall-mounting type
Note
Continuous Rating: 1.65kVA
Intermittent Rating: 3.3kVA at maximum operating load with duty cycle 5 minutes on/15 minutes off.
Intermittent Rating: 3.3kVA at maximum operating load with duty cycle 5 minutes on/15 minutes off.
Gerelateerde Links
- RS PRO 2.5 kVA Intermittent 5 Mins on 15 Mins off Site Transformer, 230V ac Primary, 110 (55V Secondary
- RS PRO 5.0 kVA Intermittent 5 Mins on 15 Mins off Site Transformer, 230V ac Primary, 110 (55V Secondary, 2 x 16A O/P
- RS PRO 2.25 kVA Intermittent 5 Mins on 15 Mins off Site Transformer, 230V ac Primary, 110 (55V Secondary, 2 x 16A O/P
- RS PRO 3.3 kVA Intermittent 5 Mins on 15 Mins off Site Transformer, 230V ac Primary, 110 (55V Secondary, 2 x 16A O/P
- RS PRO 1.5 kVA Intermittent 5 Mins on 15 Mins off Site Transformer, 230V ac Primary, 110 (55V Secondary, 2 x 16A O/P
- RS PRO 3.3 kVA Intermittent 5 Mins on 15 Mins off Site Transformer, 230V ac Primary, 110 (55V Secondary, 1 x 16 A, 1 x
- RS PRO 3 kVA Intermittent 5 Mins on 15 Mins off Site Transformer, 230V ac Primary, 110 (55V Secondary, 1 x 16 A, 1 x 32
- RS PRO 5 kVA Intermittent 5 Mins on 15 Mins off Site Transformer, 230V ac Primary, 110V Secondary