Phoenix Contact MINI MCR Series Signal Conditioner, Current, Voltage Input, Current Output, 8 → 30V dc Supply,
- RS-stocknr.:
- 764-9649
- Artikelnummer Distrelec:
- 303-48-072
- Fabrikantnummer:
- 2902829
- Fabrikant:
- Phoenix Contact
Subtotaal (1 eenheid)*
€ 248,24
(excl. BTW)
€ 300,37
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Op voorraad
- 5 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 248,24 |
*prijsindicatie
- RS-stocknr.:
- 764-9649
- Artikelnummer Distrelec:
- 303-48-072
- Fabrikantnummer:
- 2902829
- Fabrikant:
- Phoenix Contact
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Phoenix Contact | |
| Module Type | Isolation Amplifier | |
| Input Signal Type | Current, Voltage | |
| Output Signal Type | Current | |
| Input Range | (Configurable) 0 → 40 mA , (Configurable) -1000 mV → 30V | |
| Output Range | 4 → 20mA | |
| Supply Voltage | 8 → 30V dc | |
| Hazardous Area Certification | ATEX | |
| Mounting Type | DIN Rail Mount | |
| Operating Temperature Range | -25 → +70°C | |
| Series | MINI MCR | |
| Minimum Operating Temperature | -25°C | |
| Standards Met | cUL Listed, CULus, UL Listed | |
| Signal Conditioner Function | Isolation Amplifier | |
| Number of Channels | 1 | |
| Maximum Operating Temperature | +70°C | |
| Alles selecteren | ||
|---|---|---|
Merk Phoenix Contact | ||
Module Type Isolation Amplifier | ||
Input Signal Type Current, Voltage | ||
Output Signal Type Current | ||
Input Range (Configurable) 0 → 40 mA , (Configurable) -1000 mV → 30V | ||
Output Range 4 → 20mA | ||
Supply Voltage 8 → 30V dc | ||
Hazardous Area Certification ATEX | ||
Mounting Type DIN Rail Mount | ||
Operating Temperature Range -25 → +70°C | ||
Series MINI MCR | ||
Minimum Operating Temperature -25°C | ||
Standards Met cUL Listed, CULus, UL Listed | ||
Signal Conditioner Function Isolation Amplifier | ||
Number of Channels 1 | ||
Maximum Operating Temperature +70°C | ||
- Land van herkomst:
- DE
Phoenix Contact Signal Conditioner, Isolation Amplifier Module Type, -25°C to +70°C Operating Temperature Range - MINI MCR-SL-UI-I-LP-NC - 2902829
Looking for a way to protect your measurement equipment from damaging voltage spikes? Put this signal conditioner from Phoenix Contact on guard duty. It isolates and filters analogue input signals, preventing surges from reaching your sensitive instruments. As it also keeps electrical noise to a minimum, you can be sure you're getting accurate readings.
The unit accepts input signals between 2 and 40mA or 50mV and 30V, which it then converts to an output of between 4 and 20mA, so it's a versatile piece of kit. Installation is a cinch thanks to the screw terminal fittings. This kind of conditioner is typically used in data acquisition systems and medical instruments.
The unit accepts input signals between 2 and 40mA or 50mV and 30V, which it then converts to an output of between 4 and 20mA, so it's a versatile piece of kit. Installation is a cinch thanks to the screw terminal fittings. This kind of conditioner is typically used in data acquisition systems and medical instruments.
Features & Benefits
• Safe for use in industrial settings thanks to a broad operating temperature range of -25°C to +70°C
• Compact dimensions of 6.2 (W) x 93.1 (H) x 101.2mm (D) make it suitable for busy setups
• DIP switches on the housing let you configure input ranges at the click of a button
• Robust PBT housing withstands impact and chemicals, making it suitable for rugged environments
• Snaps onto a DIN rail in any position for convenience
• Compact dimensions of 6.2 (W) x 93.1 (H) x 101.2mm (D) make it suitable for busy setups
• DIP switches on the housing let you configure input ranges at the click of a button
• Robust PBT housing withstands impact and chemicals, making it suitable for rugged environments
• Snaps onto a DIN rail in any position for convenience
Gerelateerde Links
- Phoenix Contact MINI MCR Series Signal Conditioner, Current, Voltage Input, Current Output, 8 → 30V dc Supply,
- Phoenix Contact MINI MCR Series Signal Conditioner, Voltage Input, Current, Voltage Output, 9.6 → 30V dc Supply,
- Phoenix Contact MINI MCR Series Signal Conditioner, Voltage Input, Current Output, 9.6 → 30V dc Supply
- Phoenix Contact MINI MCR Series Signal Conditioner, Current, Voltage Output, 18 → 30V dc Supply, ATEX
- Phoenix Contact MINI MCR Series Signal Conditioner, Current Input, Voltage Output, 9.6 → 30V dc Supply
- Phoenix Contact MINI MCR Series Signal Conditioner, Current, Voltage Input, Frequency Output, 20 → 30V dc Supply
- Phoenix Contact MINI MCR-SL-U-U-SP Series Signal Conditioner, Current, Voltage Output, 10 → 30V dc Supply
- Phoenix Contact MINI MCR Series Signal Conditioner, RTD Input, Current, Voltage Output, 9.6 → 30V dc Supply,