Phoenix Contact MACX MCR Series Signal Conditioner, Voltage Input, Current, Voltage Output, 24V dc Supply, ATEX
- RS-stocknr.:
- 189-2314
- Artikelnummer Distrelec:
- 304-11-382
- Fabrikantnummer:
- 2902021
- Fabrikant:
- Phoenix Contact
Subtotaal (1 eenheid)*
€ 208,94
(excl. BTW)
€ 252,82
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Op voorraad
- 3 stuk(s) klaar voor verzending
- 32 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 208,94 |
*prijsindicatie
- RS-stocknr.:
- 189-2314
- Artikelnummer Distrelec:
- 304-11-382
- Fabrikantnummer:
- 2902021
- Fabrikant:
- Phoenix Contact
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Phoenix Contact | |
| Module Type | Analogue Signal Converter | |
| Input Signal Type | Voltage | |
| Output Signal Type | Current, Voltage | |
| Input Range | -50 → 50 mV, -30 V → 30V | |
| Output Range | -10 V → 10 V, 0(4) mA → 20mA | |
| Supply Voltage | 24V dc | |
| Hazardous Area Certification | ATEX | |
| Mounting Type | DIN Rail Mount | |
| Operating Temperature Range | -40 → +70°C | |
| Series | MACX MCR | |
| Standards Met | cUL Listed, CULus, UL Listed | |
| Maximum Operating Temperature | +70°C | |
| Signal Conditioner Function | Converting | |
| Minimum Operating Temperature | -40°C | |
| Alles selecteren | ||
|---|---|---|
Merk Phoenix Contact | ||
Module Type Analogue Signal Converter | ||
Input Signal Type Voltage | ||
Output Signal Type Current, Voltage | ||
Input Range -50 → 50 mV, -30 V → 30V | ||
Output Range -10 V → 10 V, 0(4) mA → 20mA | ||
Supply Voltage 24V dc | ||
Hazardous Area Certification ATEX | ||
Mounting Type DIN Rail Mount | ||
Operating Temperature Range -40 → +70°C | ||
Series MACX MCR | ||
Standards Met cUL Listed, CULus, UL Listed | ||
Maximum Operating Temperature +70°C | ||
Signal Conditioner Function Converting | ||
Minimum Operating Temperature -40°C | ||
- Land van herkomst:
- DE
Phoenix Contact Signal Conditioner, mV Input to V or mA Output, 24V Supply Voltage - MINI MCR-2-U-UI-PT - 2902021
Struggling to convert analogue electrical signals into a usable format? Delegate the task to this 3-way Mini Analogue Pro signal conditioner from Phoenix Contact. All you have to do is connect an input sensor with a voltage of up to 33V and it'll filter and isolate the signal, providing an output of up to 10V or 22mA.
The device can process both unipolar and bipolar analogue signals, making it a versatile choice. You can configure the input and output ranges using the DIP switches on the front, allowing you to tailor them to your precise needs without reaching for your toolkit.
This signal conditioner has a spring-cage connection, which makes it a breeze to plug into a terminal block, as well as screw terminals for an extra-secure fitting. A wide operating temperature range of -40°C to +70°C means it can stand up to harsh industrial conditions.
The device can process both unipolar and bipolar analogue signals, making it a versatile choice. You can configure the input and output ranges using the DIP switches on the front, allowing you to tailor them to your precise needs without reaching for your toolkit.
This signal conditioner has a spring-cage connection, which makes it a breeze to plug into a terminal block, as well as screw terminals for an extra-secure fitting. A wide operating temperature range of -40°C to +70°C means it can stand up to harsh industrial conditions.
Features & Benefits
• PBT housing is hardwearing and abrasion-resistant, so delivers a long service life
• At 110.5 (H) x 6.2 (W) x 120.5mm (D), it's compact and super-slim for installation in tight spaces
• Built-in DIN rail fixtures make it simple to snap into place for hassle-free mounting
• At 110.5 (H) x 6.2 (W) x 120.5mm (D), it's compact and super-slim for installation in tight spaces
• Built-in DIN rail fixtures make it simple to snap into place for hassle-free mounting
Gerelateerde Links
- Phoenix Contact MACX MCR Series Signal Conditioner, Voltage Input, Current, Voltage Output, 24V dc Supply, ATEX
- Phoenix Contact MACX MCR Series Signal Conditioner, Current, Voltage Input, Relay Output, 24V dc Supply, ATEX
- Phoenix Contact MACX MCR Series Signal Conditioner, Thermocouple, Voltage Input, Current Output, 24V dc Supply, ATEX
- Phoenix Contact MACX MCR Series Signal Conditioner, Current, Voltage Input, Relay Output, 24V dc Supply, ATEX, IECEx
- Phoenix Contact MACX MCR Series Signal Conditioner, Voltage Input, Voltage Output, 9.6 → 30V dc Supply, ATEX
- Phoenix Contact MACX MCR Series Signal Conditioner, Voltage Input, Resistance, Voltage Output, ATEX
- Phoenix Contact MACX MCR Series Signal Conditioner, Voltage Input, Current, Voltage Output, 24V dc Supply
- Phoenix Contact MACX MCR Series Signal Conditioner, Voltage Input, Resistance, Voltage Output, ATEX, IECEx