Phoenix Contact MACX MCR Series Signal Conditioner, Thermocouple, Voltage Input, Current Output, 24V dc Supply, ATEX
- RS Stock No.:
- 189-2306
- Mfr. Part No.:
- 1050228
- Brand:
- Phoenix Contact
Subtotal (1 unit)*
€ 283,84
(exc. VAT)
€ 343,45
(inc. VAT)
GRATIS bezorging voor bestellingen vanaf € 75,00
Op voorraad
- Plus verzending 1 stuk(s) vanaf 15 december 2025
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Units | Per unit |
|---|---|
| 1 + | € 283,84 |
*price indicative
- RS Stock No.:
- 189-2306
- Mfr. Part No.:
- 1050228
- Brand:
- Phoenix Contact
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Merk | Phoenix Contact | |
| Module Type | Temperature Converter | |
| Input Signal Type | Thermocouple, Voltage | |
| Output Signal Type | Current | |
| Input Range | -1000 → 1000 mV, -250 → +2500°C | |
| Output Range | 0 → 20 mA, 4 → 20mA | |
| Supply Voltage | 24V dc | |
| Hazardous Area Certification | ATEX | |
| Mounting Type | DIN Rail Mount | |
| Operating Temperature Range | -40 → +70°C | |
| Series | MACX MCR | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | +70°C | |
| Select all | ||
|---|---|---|
Merk Phoenix Contact | ||
Module Type Temperature Converter | ||
Input Signal Type Thermocouple, Voltage | ||
Output Signal Type Current | ||
Input Range -1000 → 1000 mV, -250 → +2500°C | ||
Output Range 0 → 20 mA, 4 → 20mA | ||
Supply Voltage 24V dc | ||
Hazardous Area Certification ATEX | ||
Mounting Type DIN Rail Mount | ||
Operating Temperature Range -40 → +70°C | ||
Series MACX MCR | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature +70°C | ||
- COO (Country of Origin):
- DE
Temperature transducer: converts signals from thermocouples and mV sources into 0/4…20 mA signals. Freely programmable, 3-way electrical isolation, screw connection, SIL.
Input for thermocouples and mV sources
4...20 mA or 20...4 mA output signal range
High level of accuracy over the entire measuring range
Configuration via software (Analogue-CONF or DTM)
Safe electrical isolation between input, output, and supply
High transmission accuracy
Status and error indicator
Power supply possible via DIN rail connector
Housing width of 12.5 mm
Screw connection available
4...20 mA or 20...4 mA output signal range
High level of accuracy over the entire measuring range
Configuration via software (Analogue-CONF or DTM)
Safe electrical isolation between input, output, and supply
High transmission accuracy
Status and error indicator
Power supply possible via DIN rail connector
Housing width of 12.5 mm
Screw connection available
Related links
- Phoenix Contact MACX MCR Series Signal Conditioner, Thermocouple, Voltage Input, Current Output, 24V dc Supply, ATEX
- Phoenix Contact MACX MCR Series Signal Conditioner, Voltage Input, Current, Voltage Output, 24V dc Supply, ATEX
- Phoenix Contact MACX MCR Series Signal Conditioner, Current, Voltage Input, Relay Output, 24V dc Supply, ATEX
- Phoenix Contact MACX MCR Series Signal Conditioner, RTD, Potentiometer Input, Current Output, 24V dc Supply, ATEX
- Phoenix Contact MACX MCR Series Signal Conditioner, RTD, Potentiometer Input, Current Output, 24V dc Supply, ATEX, IECEx
- Phoenix Contact MACX MCR Series Signal Conditioner, Current, Voltage Input, Relay Output, 24V dc Supply, ATEX, IECEx
- Phoenix Contact MACX MCR Series Signal Conditioner, Current Input, Current Output, <30.5V Supply, ATEX
- Phoenix Contact MACX MCR Series Signal Conditioner, Transistor Output, 19.2 → 30V dc Supply, ATEX, IECEx