Lapp OLFLEX CLASSIC 115 CY Control Cable, 7 Cores, 0.5 mm² CSA 20 AWG, Screened, 50 m, Silver Grey Polyvinyl Chloride
- RS-stocknr.:
- 280-5099
- Artikelnummer Distrelec:
- 300-49-534
- Fabrikantnummer:
- 1136007
- Fabrikant:
- Lapp
Subtotaal (1 rol van 50 meter)*
€ 146,45
(excl. BTW)
€ 177,20
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Op voorraad
- Plus verzending 2 stuk(s) vanaf 26 januari 2026
- Plus verzending 4 stuk(s) vanaf 26 januari 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len) | Per rol | Per meter* |
|---|---|---|
| 1 + | € 146,45 | € 2,929 |
*prijsindicatie
- RS-stocknr.:
- 280-5099
- Artikelnummer Distrelec:
- 300-49-534
- Fabrikantnummer:
- 1136007
- Fabrikant:
- Lapp
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Lapp | |
| Product Type | Control Cable | |
| Series | OLFLEX CLASSIC 115 CY | |
| Number of Cores | 7 | |
| Cross Sectional Area | 0.5 mm² | |
| Conductor Material | Copper | |
| Jacket Material | Polyvinyl Chloride | |
| Jacket Colour | Silver Grey | |
| Screened/Unscreened | Screened | |
| Cable Length | 50m | |
| Outside Diameter | 7.5 mm | |
| Voltage | 4000 V | |
| Minimum Operating Temperature | -40°C | |
| Conductor Type | Stranded | |
| Standards/Approvals | EN 50525-2-51 resp. VDE 0285-525-2-51, EU-Directives 2014/35/EU (Low Voltage Directive) | |
| Maximum Operating Temperature | 80°C | |
| Fire Behaviour | Flammability acc. to IEC 60332-1-2 resp. VDE 0482-332-1-2 | |
| American Wire Gauge | 20AWG | |
| Core Strands | 7 | |
| Alles selecteren | ||
|---|---|---|
Merk Lapp | ||
Product Type Control Cable | ||
Series OLFLEX CLASSIC 115 CY | ||
Number of Cores 7 | ||
Cross Sectional Area 0.5 mm² | ||
Conductor Material Copper | ||
Jacket Material Polyvinyl Chloride | ||
Jacket Colour Silver Grey | ||
Screened/Unscreened Screened | ||
Cable Length 50m | ||
Outside Diameter 7.5 mm | ||
Voltage 4000 V | ||
Minimum Operating Temperature -40°C | ||
Conductor Type Stranded | ||
Standards/Approvals EN 50525-2-51 resp. VDE 0285-525-2-51, EU-Directives 2014/35/EU (Low Voltage Directive) | ||
Maximum Operating Temperature 80°C | ||
Fire Behaviour Flammability acc. to IEC 60332-1-2 resp. VDE 0482-332-1-2 | ||
American Wire Gauge 20AWG | ||
Core Strands 7 | ||
Vrijgesteld
- Land van herkomst:
- DE
LAPP OLFLEX CLASSIC 115 CY Series Control Cable, 50m Length, 0.5 mm² Cross Sectional Area - 1136007
This control cable is designed for flexible and fixed installations under medium mechanical strain. With a length of 50m and a round shape, this 0.5 mm² control cable features a durable PVC sheath in silver grey. Ideal for use in various environments, it boasts a voltage rating of 300/500 V, making it suitable for demanding tasks in automation and electrical applications.
Features & Benefits
• Utilises a screened design to minimise electrical interference
• Flame retardant properties ensure safety in critical usage
• Capable of withstanding temperatures from -40°C to +80°C
• Composed of bare copper for excellent conductivity
• Rated for occasional flexible use in diverse settings
• PVC sheath offers resistance to acids and alkalis
Applications
• Utilised in control units for machine tools
• Implemented in conveyor systems for efficient operations
• Suitable for measurement and control technology
• Used in data processing systems for reliable connections
• Recommended for occasional movement, such as in wind turbines
What is the maximum load capacity during installation?
The maximum tensile load is 15 N/mm² of the conductor cross-section, ensuring it can handle significant stress during both installation and operation.
Can this cable be used outdoors?
Yes, it can be used outdoors, provided UV protection is applied, and it operates within the specified temperature range.
How does the screening impact performance?
The screening braid significantly reduces the effects of external electrical fields, allowing for consistent signal integrity in sensitive applications.
What are the bending radius specifications?
For occasional flexing, the minimum bending radius is 20 times the cable diameter, while fixed installations require a 6 times diameter bending radius.
Gerelateerde Links
- Lapp OLFLEX CLASSIC 115 CY Control Cable, 4 Cores, 1 mm² CSA 17 AWG, Screened, 50 m, Silver Grey Polyvinyl Chloride
- Lapp OLFLEX CLASSIC 115 CY Control Cable, 4 Cores, 0.75 mm² CSA 18 AWG, Screened, 50 m, Silver Grey Polyvinyl Chloride
- Lapp OLFLEX CLASSIC 115 CY Control Cable, 12 Cores, 0.75 mm² CSA 18 AWG, Screened, 50 m, Silver Grey Polyvinyl Chloride
- Lapp OLFLEX CLASSIC 115 CY Control Cable, 4 Cores, 0.5 mm² CSA 20 AWG, Screened, 50 m, Silver Grey Polyvinyl Chloride
- Lapp OLFLEX CLASSIC 115 CY Control Cable, 3 Cores, 0.75 mm² CSA 18 AWG, Screened, 50 m, Silver Grey Polyvinyl Chloride
- Lapp OLFLEX CLASSIC FD 810 CY Control Cable, 3 Cores, 1.5 mm² CSA 16, Screened, Silver Grey Polyvinyl Chloride Sheath
- Lapp OLFLEX CLASSIC FD 810 CY Control Cable, 3 Cores, 0.75 mm² CSA 19, Screened, Silver Grey Polyvinyl Chloride Sheath
- Lapp OLFLEX CLASSIC FD 810 CY Control Cable, 4 Cores, 0.75 mm² CSA 19, Screened, Silver Grey Polyvinyl Chloride Sheath