Lapp CY Control Cable, 7 Cores, 0.5 mm² CSA 20 AWG, Screened, 50 m, Black Polyvinyl Chloride Sheath
- RS-stocknr.:
- 185-5090
- Artikelnummer Distrelec:
- 304-03-784
- Fabrikantnummer:
- 1027904
- Fabrikant:
- Lapp
Subtotaal (1 rol van 50 meter)*
€ 387,75
(excl. BTW)
€ 469,18
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Op voorraad
- Plus verzending 1 stuk(s) vanaf 25 mei 2026
- Plus verzending 4 stuk(s) vanaf 25 mei 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len) | Per rol | Per meter* |
|---|---|---|
| 1 + | € 387,75 | € 7,755 |
*prijsindicatie
- RS-stocknr.:
- 185-5090
- Artikelnummer Distrelec:
- 304-03-784
- Fabrikantnummer:
- 1027904
- Fabrikant:
- Lapp
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Lapp | |
| Series | CY | |
| Product Type | Control Cable | |
| Number of Cores | 7 | |
| Cross Sectional Area | 0.5 mm² | |
| Conductor Material | Copper | |
| Jacket Material | Polyvinyl Chloride | |
| Jacket Colour | Black | |
| Screened/Unscreened | Screened | |
| Cable Length | 50m | |
| Outside Diameter | 8.5mm | |
| Voltage | 300, 500V | |
| Conductor Type | Stranded | |
| Minimum Operating Temperature | -40°C | |
| Standards/Approvals | CSA, cUL Listed, IEC/EN: 60332-1-2, UL File No. E63634, UL Listed, USA | |
| Maximum Operating Temperature | 80°C | |
| American Wire Gauge | 20AWG | |
| Fire Behaviour | Flame Retardant | |
| Core Strands | 7 | |
| Alles selecteren | ||
|---|---|---|
Merk Lapp | ||
Series CY | ||
Product Type Control Cable | ||
Number of Cores 7 | ||
Cross Sectional Area 0.5 mm² | ||
Conductor Material Copper | ||
Jacket Material Polyvinyl Chloride | ||
Jacket Colour Black | ||
Screened/Unscreened Screened | ||
Cable Length 50m | ||
Outside Diameter 8.5mm | ||
Voltage 300, 500V | ||
Conductor Type Stranded | ||
Minimum Operating Temperature -40°C | ||
Standards/Approvals CSA, cUL Listed, IEC/EN: 60332-1-2, UL File No. E63634, UL Listed, USA | ||
Maximum Operating Temperature 80°C | ||
American Wire Gauge 20AWG | ||
Fire Behaviour Flame Retardant | ||
Core Strands 7 | ||
LAPP ÖLFLEX CHAIN 819 CP Series Control Cable, 0.5mm² Cross Sectional Area, 7 Cores - 1027904
This control cable is a highly flexible option designed for demanding applications. It features a robust TPU sheath and PVC core insulation, making it suitable for various industrial environments. With a length of 50m and an outer diameter of 8.5mm, this cable combines durability and flexibility, allowing for efficient installation and use in power chains and moving machinery.
Features & Benefits
• Offers high oil and mechanical resistance for industrial use
• Screened design protects against electromagnetic interference
• Flame-retardant properties ensure safety compliance
• Compliant with multiple industry standards to reduce inventory
Applications
• Suitable for use in power chains and moving machine components
• Ideal for environments sensitive to electromagnetic disturbances
• Effective in oily wet areas within production and machinery
• For control and regulation circuits in various machines
• Applicable in indoor environments where durability is required
What is the significance of the screening in this cable?
The screening provided by the tinned copper braiding serves to protect the cable from electromagnetic interference, ensuring reliable signal transmission in EMC-sensitive applications.
How does the cable's temperature range benefit its use in various environments?
Its wide temperature range of -40°C to +80°C allows for safe operation in diverse conditions, making it suitable for both indoor and outdoor applications without compromising performance.
Can this cable withstand exposure to chemicals?
Yes, the robust TPU sheath is resistant to contact with many mineral oil-based lubricants, diluted acids, and alkaline solutions, making it ideal for industrial settings where chemical exposure is likely.
What installation considerations should be taken into account?
When installing, ensure to adhere to the minimum bending radius of 10 times the outer diameter for flexing applications and 4 times for fixed installation to maintain cable integrity.
Note
For suitable cable gland see part number 839-5331
Gerelateerde Links
- Lapp CY Control Cable, 12 Cores, 0.5 mm² CSA, Screened, 50 m, Black Polyvinyl Chloride Sheath
- Lapp CY Control Cable, 2 Cores, 0.5 mm² CSA, Screened, 100 m, Black Polyvinyl Chloride Sheath
- Lapp CY Control Cable, 2 Cores, 0.5 mm² CSA 20 AWG, Screened, 50 m, Transparent Polyvinyl Chloride Sheath
- Lapp CY Control Cable, 5 Cores, 0.5 mm² CSA 20 AWG, Screened, 50 m, Black Polyvinyl Chloride Sheath
- Lapp CY Control Cable, 18 Cores, 0.5 mm² CSA 20 AWG, Screened, 50 m, Black Polyvinyl Chloride Sheath
- Lapp CY Control Cable, 25 Cores, 0.5 mm² CSA 20 AWG, Screened, 50 m, Black Polyvinyl Chloride Sheath
- Lapp CY Control Cable, 4 Cores, 0.5 mm² CSA 20 AWG, Screened, 50 m, Black Polyvinyl Chloride Sheath
- Lapp CY Control Cable, 5 Cores, 0.5 mm² CSA 20 AWG, Screened, 50 m, Transparent Polyvinyl Chloride Sheath