Phoenix Contact Safety Controller
- RS-stocknr.:
- 666-7110
- Fabrikantnummer:
- 2986135
- Fabrikant:
- Phoenix Contact
Subtotaal (1 eenheid)*
€ 16,07
(excl. BTW)
€ 19,44
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Op voorraad
- Plus verzending 3 stuk(s) vanaf 08 december 2025
- Plus verzending 3 stuk(s) vanaf 08 december 2025
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 16,07 |
*prijsindicatie
- RS-stocknr.:
- 666-7110
- Fabrikantnummer:
- 2986135
- Fabrikant:
- Phoenix Contact
Datasheets
Wetgeving en conformiteit
Productomschrijving
- Land van herkomst:
- CN
PSR-TRISAFE-S Safety Controller
The PSR-TRISAFE-S is a standalone safety controller with 20 safe inputs, four safe outputs and two safe ground-switching outputs. If additional safe outputs or safe relay outputs are needed, standard safety relay expansion modules can be hard-wired to the safe outputs of the PSR-TRISAFE-S module. System designers should consider adding a safety expansion relay for one of two reasons: (a) the PSR-TRISAFE-S module does not have enough safe outputs; (b) a safe relay circuit is needed to switch a voltage other than 24 Vdc. The PSR-TRISAFE-S module is a 24 V solid-state device.
Intuitive three step software
Manipulation proof: Password protect against unathorised changes in the safety logic of the hardware and software: Protect against unwanted changes in the safety logic with the front of device "CONFIRM" button
All commonly used safety functions can be implemented easily and flexibly: E-stop and guard door monitoring, non-contact switches, safety sensors, laser scanners, optical devices (with or without muting) as well as safe mode selection, enabling switches, two hand control devices
2 clock outputs, 4 alarm outputs and ground switching output to increase safety of monitoring circuit
Manipulation proof: Password protect against unathorised changes in the safety logic of the hardware and software: Protect against unwanted changes in the safety logic with the front of device "CONFIRM" button
All commonly used safety functions can be implemented easily and flexibly: E-stop and guard door monitoring, non-contact switches, safety sensors, laser scanners, optical devices (with or without muting) as well as safe mode selection, enabling switches, two hand control devices
2 clock outputs, 4 alarm outputs and ground switching output to increase safety of monitoring circuit
Standards
EN954-1 to Category 4, ISO 13849-1 to PLe, IEC 62061 to SILCL 3 for machine and system engineering
SIL3 to IEC 61508 for the Process Industry
SIL3 to IEC 61508 for the Process Industry
Approvals
TUV FS, UL, cUL
Gerelateerde Links
- Phoenix Contact Safety Controller
- Phoenix Contact 2701 Series Safety Controller, 8 Safety Outputs, 7.5 V
- Phoenix Contact IB IL Series Safety Controller, 2 Safety Inputs, 24 V
- Phoenix Contact CHARX Series Safety Controller, 4 Safety Inputs, 4 Safety Outputs, 12 V
- Phoenix Contact PLCnext Control Series Safety Controller, 24 V dc
- Phoenix Contact IB IL 24 PSDI 16-PAC Series Safety Controller, 16 Safety Inputs, 24 V
- Safety Automation Controllers
- Phoenix Contact RFC 480S PN 4TX RFC 480S PN 4TX Series Safety Controller, 24 V dc