SICK FXL1 Series Safety Controller, 2 Safety Outputs, 24V dc

Subtotaal (1 eenheid)*

€ 536,62

(excl. BTW)

€ 649,31

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • Plus verzending 7 stuk(s) vanaf 03 november 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 536,62

*prijsindicatie

RS-stocknr.:
285-9514
Fabrikantnummer:
FXL1-SPEUSA00
Fabrikant:
SICK
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

SICK

Series

FXL1

Product Type

Safety Controller

Number of Safety Outputs

2

Safety Category

4

Supply Voltage

24V dc

Contact Current

100mA

Terminal Type

M12 Connector

Width

40mm

Length

180mm

Depth

45mm

IP Rating

IP69K, IP65, IP67

Land van herkomst:
MY

SICK FXL1 Series Safety Controller, 24V DC Supply Voltage, 2 Safety Outputs - FXL1-SPEUSA00


This safety controller provides monitored safety locking and access control for industrial machinery. Designed for use where coded RFID actuation and power-to-release locking are required, it delivers self‑monitoring semiconductor outputs and diagnostic indication via LEDs. The unit operates from a 24V DC supply and integrates with control systems using M12 plug connections, offering suitability for harsh environments.

Features and Benefits:


• SIL 3 safety integrity level for high-risk applications
• PL e Category 4 performance to meet strict safety demands
• Two PNP semiconductor safety outputs with 100mA limit
• Peak current 800mA for 200 MS to cover actuation spikes
• IP69K, IP67 and IP65 enclosure protection for wash‑down

Applications


• Suitable for guarded access on production lines
• Used with safety relays for interlock monitoring
• Ideal for installations requiring coded RFID actuation
• Can be used in food‑industry wash‑down environments
• Used with PLCs via M12 connector for machine integration

What connector type is provided for system wiring?


An 8‑pin M12 plug connector is fitted for power and I/O.

How does the unit indicate diagnostic status?


Built‑in LEDs provide status and diagnostic information.

What is the device’s operational temperature range?


It functions between -20°C and +55°C.

How long is the expected mission time for safety calculations?


The mission time specified for safety data is 20 years.

What mechanical endurance can be expected?


The device is rated for 1x10^6 switching cycles.