SICK Flexi Soft FX0 Series Safety Controller, 5 Safety Inputs, 5 Safety Outputs
- RS-stocknr.:
- 284-9234
- Fabrikantnummer:
- FX0-GDEV00000
- Fabrikant:
- SICK
Subtotaal (1 eenheid)*
€ 489,95
(excl. BTW)
€ 592,84
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Tijdelijk niet op voorraad
- Verzending vanaf 17 februari 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 489,95 |
*prijsindicatie
- RS-stocknr.:
- 284-9234
- Fabrikantnummer:
- FX0-GDEV00000
- Fabrikant:
- SICK
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | SICK | |
| Range | Flexi Soft | |
| Series | FX0 | |
| Number of I/O | 5 | |
| Number of Safety Inputs | 5 | |
| Number of Safety Outputs | 5 | |
| Display Type | No | |
| Field Bus Communication Type | DeviceNet | |
| Terminal Type | Open Style Female Connector | |
| IP Rating | IP20 | |
| Width | 22.5mm | |
| Length | 96.5mm | |
| Depth | 131mm | |
| Dimensions | 22.5 x 96.5 x 131 mm | |
| Alles selecteren | ||
|---|---|---|
Merk SICK | ||
Range Flexi Soft | ||
Series FX0 | ||
Number of I/O 5 | ||
Number of Safety Inputs 5 | ||
Number of Safety Outputs 5 | ||
Display Type No | ||
Field Bus Communication Type DeviceNet | ||
Terminal Type Open Style Female Connector | ||
IP Rating IP20 | ||
Width 22.5mm | ||
Length 96.5mm | ||
Depth 131mm | ||
Dimensions 22.5 x 96.5 x 131 mm | ||
- Land van herkomst:
- HU
Overview
The Safety controllers Flexi Soft support Device Net industrial network connectivity. They feature 1 female connector, Open Style, with 5 pins for connection. These controllers do not come with a protective coating for more challenging ambient conditions. The Flexi Soft safety controller can be programmed via software. Thanks to the modular hardware platform, Flexi Soft provides a tailored and efficient solution for a whole host of safety applications. A wide range of modules are available: main modules, gateways, digital and analogue input/output modules, Motion Control modules, as well as relay modules.
The license-free Flexi Soft Designer configuration software enables intuitive programming, rapid commissioning, and continuous diagnostics down to the automation level. Functions to enable safe controller networking, safe series connection, or safe drive monitoring reduce costs and boost productivity. A whole host of additional functions means that Flexi Soft is able to bridge the gap to system solutions from SICK.
At a glance
Safety controller with modular hardware platform
Configuration saved in the system plug
Safe controller networking with Flexi Line
Safe series connection with Flexi Loop
Safe drive monitoring
Safe analogue value monitoring
Flexi Soft Designer license-free configuration software
Configuration saved in the system plug
Safe controller networking with Flexi Line
Safe series connection with Flexi Loop
Safe drive monitoring
Safe analogue value monitoring
Flexi Soft Designer license-free configuration software
Your Benefit
Modular adaptation to the particular requirement means optimum scalability and therefore cost savings
Intuitive configuration software featuring comprehensive functions for straightforward engineering
Rapid verification of the safety application: The configuration software provides documentation and a wiring diagram
The main module's diagnostics interfaces and the configuration storage facility in the system plug enable rapid commissioning, component replacement, and troubleshooting, resulting in minimum downtimes
Intuitive configuration software featuring comprehensive functions for straightforward engineering
Rapid verification of the safety application: The configuration software provides documentation and a wiring diagram
The main module's diagnostics interfaces and the configuration storage facility in the system plug enable rapid commissioning, component replacement, and troubleshooting, resulting in minimum downtimes
Applications
Fields of applications
Machines requiring average to complex safety logic, e.g., presses and laser cutting systems
Machines with a large number of doors and flaps that require protective measures, as well as with decentralized safety paths, such as packag
Machines requiring average to complex safety logic, e.g., presses and laser cutting systems
Machines with a large number of doors and flaps that require protective measures, as well as with decentralized safety paths, such as packag
Note
Gerelateerde Links
- SICK Flexi Soft FX3 Series Safety Controller, 96 Safety Inputs, 48 Safety Outputs, 24 V dc
- SICK Flexi Classic UE410 Series Safety Controller, 3 Safety Inputs, 3 Safety Outputs
- SICK UE410 Series Safety Controller
- SICK FX0 Series Safety Module, Via FLEXBUS
- SICK FX0 Series Safety Module, 24 V dc
- SICK Flexi Soft Series Input Module, 8 Inputs, , 0 Outputs, 24 V dc
- SICK FX0 Series Input/Output Module, 24 V dc
- SICK Flexi Soft Series Input/Output Module, 8 Inputs, 4 Outputs, 24 V dc