Europa EUR1 Series Residual Current Circuit Breaker, 100A, 4-Pole, 100 mA, Type AC, 10 kA 400V ac
- RS-stocknr.:
- 916-0417
- Fabrikantnummer:
- EUR1100.100/4
- Fabrikant:
- Europa
Momenteel niet beschikbaar
We weten niet of dit item nog op voorraad komt, RS is van plan dit binnenkort uit ons assortiment te halen.
- RS-stocknr.:
- 916-0417
- Fabrikantnummer:
- EUR1100.100/4
- Fabrikant:
- Europa
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Europa | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 100A | |
| Number of Poles | 4 | |
| Range | EUR1 | |
| Series | EUR1 | |
| Trip Sensitivity | 100mA | |
| Mount Type | DIN Rail | |
| Tripping Characteristics | Type AC | |
| Terminal Type | Tunnel | |
| Standards/Approvals | EN 61008-1, CE, BS EN 61008-1, UKCA | |
| Width | 83mm | |
| Height | 78mm | |
| Depth | 78mm | |
| Breaking Capacity | 10kA | |
| Earth Leakage Protection Type | Type A | |
| Tripping Mechanism | Electromagnetic | |
| Reset Actuator Type | Toggle Switch | |
| Rated AC Voltage | 400V ac | |
| Alles selecteren | ||
|---|---|---|
Merk Europa | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 100A | ||
Number of Poles 4 | ||
Range EUR1 | ||
Series EUR1 | ||
Trip Sensitivity 100mA | ||
Mount Type DIN Rail | ||
Tripping Characteristics Type AC | ||
Terminal Type Tunnel | ||
Standards/Approvals EN 61008-1, CE, BS EN 61008-1, UKCA | ||
Width 83mm | ||
Height 78mm | ||
Depth 78mm | ||
Breaking Capacity 10kA | ||
Earth Leakage Protection Type Type A | ||
Tripping Mechanism Electromagnetic | ||
Reset Actuator Type Toggle Switch | ||
Rated AC Voltage 400V ac | ||
- Land van herkomst:
- CN
Europacomponents EUR1 Series RCCB
Europa Components EUR1 RCCB series provide ground fault protection by monitoring the leakage of current to ground when used with standard MCBs. The EUR1 series are compact DIN Rail-mounted RCCBs and feature a wide range of trip ratings to offer complete protection for commercial or industrial applications.
Compact AC DIN Rail mount 2 and 4 Pole RCCBs
Protects against the effects of sinusoidal alternating earth fault currents
Protects against indirect contact, with additional protection against direct contact
Command and isolation of resistive and inductive circuits
Suitable for residential and commercial applications
Europacomponents Circuit Protection Devices
Note
RCCBs are sensitive only to earth fault current (therefore they have to be connected in series with an MCB or a fuse to protect them against overcurrent and short circuits).
Gerelateerde Links
- Europa EUR1 Series Residual Current Circuit Breaker, 80A, 4-Pole, 30 mA, Type A, 10 kA 415V ac
- Europa EUR1 Series Residual Current Circuit Breaker, 80A, 4-Pole, 300 mA, Type A, 10 kA 415V ac
- Europa EUR1 Series Residual Current Circuit Breaker, 25A, 4-Pole, 30 mA, Type A, 10 kA 415V ac
- Europa EUR1 Series Residual Current Circuit Breaker, 25A, 4-Pole, 100 mA, Type A, 10 kA 415V ac
- Europa EUR1 Series Residual Current Circuit Breaker, 40A, 4-Pole, 100 mA, Type A, 10 kA 415V ac
- Europa EUR1 Series Residual Current Circuit Breaker, 63A, 4-Pole, 100 mA, Type A, 10 kA 415V ac
- Europa EUR1 Series Residual Current Circuit Breaker, 63A, 4-Pole, 30 mA, Type A, 10 kA 415V ac
- Europa EUR1 Series Residual Current Circuit Breaker, 40A, 4-Pole, 30 mA, Type A, 10 kA 415V ac
