Schneider Electric GFP Series Residual Current Circuit Breaker, 40A, 2-Pole, 26 mA, Type A, 10 kA 240V ac
- RS-stocknr.:
- 211-2465
- Fabrikantnummer:
- M9R81240
- Fabrikant:
- Schneider Electric
Momenteel niet beschikbaar
We weten niet of dit item nog op voorraad komt, RS is van plan dit binnenkort uit ons assortiment te halen.
Alternatief
Dit product is momenteel niet beschikbaar. Hierbij onze aanbeveling voor een alternatief product.
Per stuk
€ 88,68
(excl. BTW)
€ 107,30
(incl. BTW)
- RS-stocknr.:
- 211-2465
- Fabrikantnummer:
- M9R81240
- Fabrikant:
- Schneider Electric
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Schneider Electric | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 40A | |
| Number of Poles | 2 | |
| Series | GFP | |
| Range | Multi9 | |
| Trip Sensitivity | 26mA | |
| Tripping Characteristics | Type A | |
| Mount Type | DIN Rail | |
| Terminal Type | Screw | |
| Standards/Approvals | RoHS, REACH | |
| Depth | 60mm | |
| Height | 81mm | |
| Width | 36mm | |
| Breaking Capacity | 10kA | |
| Rated AC Voltage | 240V ac | |
| Tripping Mechanism | Electromagnetic | |
| Earth Leakage Protection Type | Type A | |
| Reset Actuator Type | Toggle Switch | |
| Break Time | Instantaneous | |
| Alles selecteren | ||
|---|---|---|
Merk Schneider Electric | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 40A | ||
Number of Poles 2 | ||
Series GFP | ||
Range Multi9 | ||
Trip Sensitivity 26mA | ||
Tripping Characteristics Type A | ||
Mount Type DIN Rail | ||
Terminal Type Screw | ||
Standards/Approvals RoHS, REACH | ||
Depth 60mm | ||
Height 81mm | ||
Width 36mm | ||
Breaking Capacity 10kA | ||
Rated AC Voltage 240V ac | ||
Tripping Mechanism Electromagnetic | ||
Earth Leakage Protection Type Type A | ||
Reset Actuator Type Toggle Switch | ||
Break Time Instantaneous | ||
- Land van herkomst:
- ES
The Schneider Electric Multi 9 GFP series is a Residual current circuit breaker (RCCB) with a Type A-SI Earth-leakage protection class. They are used for control and disconnection of electric circuits, protection of people against electric shock by direct and indirect contacts, protection of installations against insulation faults, enhanced continuity of supply, during a series of close lightning strokes.
Enhanced earth leakage protection
Protection of installations against insulation faults
Gerelateerde Links
- Schneider Electric GFP Series Residual Current Circuit Breaker, 40A, 2-Pole, 26 mA, Type A, 10 kA 240V ac
- Schneider Electric GFP Series Residual Current Circuit Breaker, 40A, 2-Pole, 26 mA, Type A, 10 kA
- Schneider Electric GFP Series Residual Current Circuit Breaker, 63A, 2-Pole, 26 mA, Type A-SI, 1.5 kA 240V
- Schneider Electric GFP Series Residual Current Circuit Breaker, 40A, 4-Pole, 260 mA, Type A, 10 kA
- Schneider Electric GFP Series Residual Current Circuit Breaker, 25A, 2-Pole, 26 mA, Type A, 10 kA
- Schneider Electric GFP Series Residual Current Circuit Breaker, 63A, 4-Pole, 26 mA, Type A, 10 kA
- Schneider Electric GFP Series Residual Current Circuit Breaker, 100A, 4-Pole, 260 mA, Type A, 10 kA
- Schneider Electric GFP Series Residual Current Circuit Breaker, 25A, 2-Pole, 260 mA, Type A, 10 kA