ABB FS401 RCCB, 16A, 1+N Pole, 30mA, Type B
- RS-stocknr.:
- 176-807
- Fabrikantnummer:
- 2CCL562111E0165 - FS401E-B16/0.03
- Fabrikant:
- ABB
Momenteel niet beschikbaar
We weten niet of dit item nog op voorraad komt, RS is van plan dit binnenkort uit ons assortiment te halen.
- RS-stocknr.:
- 176-807
- Fabrikantnummer:
- 2CCL562111E0165 - FS401E-B16/0.03
- Fabrikant:
- ABB
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Circuit Breaker Type | RCBO | |
| Current Rating | 16A | |
| Number of Poles | 1+N | |
| Range | SMISSLINE | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type B | |
| Series | FS401 | |
| Break Time | Instantaneous | |
| Mounting Style | DIN Rail Mount | |
| Rated AC Voltage | 230V | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Circuit Breaker Type RCBO | ||
Current Rating 16A | ||
Number of Poles 1+N | ||
Range SMISSLINE | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type B | ||
Series FS401 | ||
Break Time Instantaneous | ||
Mounting Style DIN Rail Mount | ||
Rated AC Voltage 230V | ||
- Land van herkomst:
- CH
ABB RCD Switch, 230V AC Rated Voltage, Type B Tripping - FS401 Series - 2CCL562111E0165 - FS401E-B16/0.03
Improve electrical safety with this RCD switch from ABB. The device trips the power to an attached circuit to prevent electric shocks and fires when there's contact with live wires. Integrated input wiring lets you easily snap the component into a plug-in socket, saving you from creating connections. You can conveniently swap it around with other elements, thanks to the modular design. It's a lightweight unit at just 250g and puts minimal strain on assemblies. Simply clip it onto a DIN rail for quick and tool-free installation.
Features & Benefits
• 230V AC voltage rating makes it compatible with standard electrical circuits
• Instantaneous break time ensures immediate tripping during faults
• Type-B tripping for resistive loads
• Instantaneous break time ensures immediate tripping during faults
• Type-B tripping for resistive loads
Applications
• Domestic appliances
• Lighting systems
• Uninterruptible power supplies
• Surge suppressors
• Lighting systems
• Uninterruptible power supplies
• Surge suppressors
What's the difference between an RCD and an MCB?
MCBs typically protect against overcurrent and short circuits, while an RCD detects earth leakages to safeguard against injuries and fires. For complete protection, you should use these devices together.
Does an RCD work without a neutral?
The device will function without a neutral, but it's not advised, as the testing function may not work. This RCD comes with a neutral connection.
Gerelateerde Links
- ABB FS401 RCCB, 16A, 1+N Pole, 30mA, Type C
- ABB RCCB, 16A, 2 Pole, 30mA, Type B, 240V ac
- ABB F200 RCCB, 80A, 4 Pole, 30mA, Type B, 400V ac
- ABB F200 RCCB, 125A, 4 Pole, 30mA, Type B, 400V ac
- Siemens 5SV3321 RCCB, 16A, 2 Pole, 30mA, Type B, 230V ac
- Schneider Electric Acti9 iID RCCB, 16A, 2 Pole, 30mA, Type B-EV, 230V
- ABB F204 RCCB, 40A, 4 Pole, 30mA
- ABB F200 RCCB, 40A, 2 Pole, 30mA, 230V ac